Number

Event Description

 

 

21

The 2.5 volts power supply failed.

 

 

22

The 2.5 volts power supply failure has cleared.

 

 

23

There is a Real Time Clock battery failure.

 

 

24

The unit has been configured to transmit and/or receive video streams beyond

 

its capability.

 

 

25

Signifies the overloaded unit is recovered to normal.

 

 

26

A component on the main board failed Power On Self Test (POST).

 

 

27

The encoder card in Slot1 failed Power On Self Test (POST).

 

 

28

The encoder card in Slot1 failed Power On Self Test (POST).

 

 

Configuration: System > Security

Note If you disable Telnet, FTP, IWS, and SNMP, the only way to manage (and re-enable) these parameters is to connect a PC to the VBrick with a serial cable and use the Command Line Interface (CLI). You should never disable all the network management interfaces if you are using COM2 for serial passthrough.

External Telnet

Default = Enabled. Disabled will prevent Telnet sessions to the

Server

server.

 

 

External FTP Server

Default = Enabled. Disabled will prevent FTP sessions to the server

 

including downloading to the VBrick. Note that this feature must be

 

enabled to upgrade the appliance firmware using VBDownload.

 

 

80

© 2008 VBrick Systems, Inc.

Page 90
Image 90
VBrick Systems VB6000, VB4000, VB5000 manual Configuration System Security