VBrick Systems VB6000, VB4000, VB5000 Configuration System SNMP Traps, Front Panel LCD Display

Models: VB6000 VB5000 VB4000

1 156
Download 156 pages 46.18 Kb
Page 87
Image 87
Front Panel LCD Display

WM Configuration

Current

Indicates the current operational mode of the VBrick. The following

Operational Mode

modes are supported. Note: Changing the Operational Mode

 

automatically reboots the VBrick.

 

 

Configured

Indicates the configured operational mode of the VBrick. The

Operational Mode

following modes are supported:

 

• Run Mode – Normal operation.

 

• Diagnostics – User selected mode for running certain VBrick

 

diagnostics.

 

 

Time Zone

Select from list: (GMT-12) Eniwetok – (GMT +12) Auckland.

 

 

Daylight Savings

Enabled or Disabled.

Time

 

 

 

IR Enable

Enable or Disable the IR remote control. This is the master enable and

 

disable for the IR across all functions.

 

 

Fan Mode

This option allows a user to either force the fan always high or to

 

automatically cycle on and off based on measured temperature. Default

 

= Automatic.

 

 

SAP Timing

Fixed or Variable - If fixed, the SAP timing will operate as defined in

Method

the encoder, decoder and pump screens with fixed SAP transmission

 

and timeouts. If variable is selected, the entire VBrick will use SAP

 

timing as defined in RFC 2974. For most applications, Fixed Timing

 

should be used.

 

 

RFC2974

Allows setting the SAP bandwidth allocation in bits per second. This

Bandwidth

setting is used only when the Timing Method is set to Variable.

 

 

Relay Control

This option allows forcing the relay connection to Open or Closed.

 

 

Front Panel LCD Display

These settings will be displayed for approximately 6 seconds. After 6 seconds the LCD will display the current release, IP address, hostname, plus transmit and receive addresses and other status information.

Box IP Address

Enable or Disable the Box IP Address display on the Front Panel

 

Display.

 

 

Destination IP

Enable or Disable the Destination IP Address display on the Front

Address

Panel Display.

 

 

User String Enabled

Enable or Disable the text displayed on the front panel LCD of the

 

VBrick appliance can be user defined.

 

 

Top Line User

The top line can support up to 16 characters. (characters in excess of

String

16 will scroll across the display for the bottom line).

 

 

Bottom Line User

The bottom line up to 40 characters.

String

 

 

 

Configuration: System > SNMP Traps

SNMP Traps are a subset of the SNMP management component of the VBrick. Use of any element of the SNMP management system requires use of an SNMP browser or SNMP

VBrick WM Appliance Admin Guide

77

Page 87
Image 87
VBrick Systems VB6000, VB4000, VB5000 manual Configuration System SNMP Traps, Front Panel LCD Display