MENU (“SET) MODE

Set Mode Item [F30 SCN CVRG] Function: Selects the Scan range. Available Values: IN BAND/HAM BAND Default: IN BAND

IN BAND: The FTM-10Rconsiders the 144 MHz Amateur Band and 430 MHz Ama- teur Band to be independent bands, and scans only the 144 MHz Amateur Band, or only the 430 MHz Amateur Band.

HAM BAND:The FTM-10Rconsiders the 144 MHz Amateur Band and 430 MHz Ama- teur Band to be one band and scans it when the scan mode is engaged.

Activate the scanner across the 144 MHz Amateur Band and 430 MHz Amateur Band.

Set Mode Item [F31 SCN DRCT] Function: Select the Scan type. Available Values: NORMAL/RETURN Default: NORMAL

NORMAL: When the VFO frequency reaches the high band edge of the current band, the VFO frequency will jump to the low band edge of the current band (or vice versa).

RETURN: When the VFO frequency reaches the high band edge of the current band while scanning upward, the scanner will reverse direction and scan downwards. (or vice versa).

Set Mode Item [F32 SCN MODE]

Function: Selects the Scan Resume mode.

Available Values: BUSY/HOLD/TIME 3S/TIME 5S/TIME 10S

Default: BUSY

BUSY: The scanner will hold until the signal disappears, then will resume when the carrier drops.

HOLD: The scanner will stop when a signal is received, and will not restart.

TIME 3S/5S/10S: The scanner will hold for selected resume time, then resume whether or not the other station is still transmitting.

Set Mode Item [F33 SCN STRT]

Function: Select the scan start direction which initiates the scanner using the scan com- mand by pressing the key.

Available Values: UP START/DN.START

Default: UP START

FTM-10R OPERATING MANUAL