If you want to PING using the System Self Test screen (diagnostics page) shown above, enter your DNS or IP address in the fields provided and click on the test button. The System Self Test will run a diagnostic test that executes independent of firewall security settings. See the following table for test descriptions and possible responses.

If you want to PING using the MS-DOS (shell) window, first you will need to check your firewall security setting. (If you PING via DOS shell you are susceptible to firewall rules, as this PING is dependent on your Router's firewall settings.) If your firewall is set to Medium or High, you will not be able to PING. You must set your firewall security setting to Low or None.

 

 

Connection/Status

 

 

 

DSL

The Router checks the status of the Router connection.

 

 

 

 

Possible responses are:

 

 

 

 

UP: The Router is operating correctly and has obtained synchronization with the

 

 

 

opposing network device.

 

 

 

 

DOWN: The Router is operating correctly, but has not synchronized with the

 

 

 

opposing device.

 

 

 

PPPoE

Indicates that a PPPoE session is or is not established.

 

 

 

(Depending on the

 

 

 

 

connection protocol used:

Possible responses are:

 

 

 

PPPoE, PPPoA, Bridge,

Session UP: A valid PPPoE session has been detected.

 

 

 

Classic IPoA)

No Session: Currently there is no active PPPoE session established.

 

 

 

 

Initiating Session: A PPP session must be connected from the homepage screen.

 

 

PPP

Indicates that a PPP session must already be established.

 

 

 

(Depending on the

 

 

 

 

connection protocol used:

Possible responses are:

 

 

 

PPPoE, PPPoA, Bridge,

Connection UP: The Router has established a connection

 

 

 

Classic IPoA)

No Connection: There is no PPP connection

 

 

 

 

Initiating Connection: The PPP connection process has been initiated

 

 

 

 

Connection Halted: A successful PPP connection was halted

 

 

 

 

Cannot Connect: A PPP connection could not be made because of a PPP session

 

 

 

failure.

 

 

 

 

Authorization Failure: The user name or password is incorrect.

 

 

 

 

Link Control Protocol Failed: Re-establish the session (from the home page).

 

 

 

Test Description / Test Results

 

 

 

Self Test

Performs an integrity check of certain internal components of the Router.

 

 

 

 

 

 

PING ISP’s Router

Performs an IP network check (i.e., an IP Ping) of the Service Provider’s Router.

 

 

This test verifies that the Router can exchange IP traffic with an entity on the other

 

 

 

side of the DSL line.

 

 

 

 

Possible responses are:

 

 

 

 

Success: The Router has detected an IP Remote Router connection.

 

 

 

 

No Response: The IP Remote Router does not answer the IP Ping.

 

 

 

 

Could not test: The test could not be executed due to Router settings. Check your

 

 

 

DSL sync or your PPP session. You must have both a DSL sync and a PPP

 

 

 

connection established to execute a PING.

 

 

 

DNS

Performs a test to try to resolve the name of a particular host. The host name is

 

 

 

entered in the input box.

 

 

 

 

Possible responses are:

 

 

 

 

 

 

 

 