AUTO SETUP

Troubleshooting for the auto setup procedure

Before auto setup

Error message

Cause

Remedy

 

 

 

Connect MIC!

Optimizer microphone is not connected.

• Connect the supplied optimizer microphone to the

 

 

OPTIMIZER MIC jack on the front panel.

 

 

 

Unplug Phones!

Headphones are connected.

• Unplug the headphones.

 

 

 

No Setup Menu!

No setup menu items have been selected.

• Select at least one setup menu item.

 

 

 

Memory Guard!

This setting is protected.

• Remove the protection setting for auto setup (see

 

 

page 78).

 

 

 

During auto setup

Press l / h to display detailed information for individual errors. Select Retry to try the auto setup procedure again.

Error message

Cause

Remedy

 

 

 

E01:No Front SP

Front L/R channel signal(s) is (are) not

• Select the front speakers with SPEAKERS A or B.

 

detected.

• Check the front L/R speaker connections.

 

 

 

E02:No Surr. SP

A surround channel signal is not detected.

• Check the surround speaker connections.

 

 

 

E03:No Pres. SP

A presence channel signal is not detected.

• Check the presence speaker connections.

 

 

 

E04:SBR ->SBL

Only the surround back right channel signal is

• Connect the surround back speaker to the LEFT

 

detected.

SURROUND BACK SPEAKERS terminal if you

 

 

only have one surround back speaker.

 

 

 

E05:Noisy

Background noise is too loud.

• Try auto setup in a quiet environment.

 

 

• Turn off noisy electric equipment like air

 

 

conditioners, or move it away from this unit.

 

 

 

E06:Check Surr.

Surround back speaker(s) is (are) connected,

• Connect surround speakers when using (a) surround

 

though surround L/R speakers are not.

back speaker(s).

 

 

 

E07:No MIC

The optimizer microphone was unplugged

• Connect the supplied optimizer microphone to the

 

during the auto setup procedure.

OPTIMIZER MIC jack on the front panel.

 

 

 

E08:No Signal

The optimizer microphone does not detect test

• Check the microphone setting.

 

tones.

• Check the speaker connections and placement.

 

 

 

E09:User Cancel

The auto setup procedure was cancelled

• Perform the auto setup procedure again.

 

because a setting that affects auto setup was

 

 

changed during the procedure.

 

 

 

 

E10:Internal Err

No DSP response.

• Restart this unit, then try the auto setup procedure

 

 

again.

 

 

 

E11:Complex Err

Multiple errors occurred.

• Check the speaker connections and placement.

 

 

 

E12:No Speaker

All 9 speakers and 2 subwoofers are not

• Check the speaker connections and placement.

 

connected.

 

 

 

 

PREPARATION

English

35