4Press the buttons for the functions you want to include in the macro operation in sequence.
You can set up to 10 steps (10 functions). After you have set 10 steps, FULL appears and the remote control automatically exits the macro mode.
(U.S.A. model)
POWER POWER STANDBY POWER
REMOTE CONTROL FEATURES
Using CLEAR
You can clear all changes made in each function set, such as learned functions, macros, renamed source names and setup remote control codes.
■Basic CLEAR operations
1Set AMP/SOURCE/TV to AMP or SOURCE.
TV | AV |
| MCR 2: AV POWER |
A | XM 2 | AUDIO SEL | SLEEP |
|
|
| MCR 3: AUDIO SEL |
PHONO | TUNER | 3 | MULTI CH IN |
CD | |||
CBL/SAT | MD/TAPE | ||
DTV | VCR 1 | DVR/VCR2 | DVD |
MCR 1: DVD
1
AMP
SOURCE
TV
2Press CLEAR by using a ballpoint pen or similar object.
CLEAR appears in the display window.
Indicates the | CLEAR |
number of macro |
|
steps entered |
|
Note |
Flashes alternately so you can | If you do not complete each of the following steps within 30 | |
seconds, the clearing mode will be automatically canceled. | ||
set the next step | ||
In this case, press CLEAR again. | ||
|
Note
To change the selected source component, press SELECT k / n. Pressing the input selector buttons will program a macro step, whereas SELECT k / nonly changes the selected component and corresponding component control area.
5Press MACRO again when the operation sequence you want to program is complete.
Note
ERROR appears in the display window if you press a button not indicated in the respective step, or if you press more than one button simultaneously.
Memory back-up
The memory
3Press k / n to select the clear mode.
L;CD | Clears all learned functions in the respective |
| component control area. Press an input selector |
| button to select the component. |
L;AMP | Clears all learned functions for this unit’s control |
| area. |
L;ALL | Clears all learned functions. |
M;ALL | Clears all programmed macros. |
RNAME | Clears all renamed source names. |
FCTRY | Clears all remote functions and returns the remote |
| to the factory settings. |
Note
The name of a component is shown after a semicolon (;).
4Press and hold CLEAR again for about 3 seconds.
WAIT appears in the display window. If clearing was successful, C;OK appears in the display window.
CLEAR
y
Once you have cleared a learned function for a button, the button reverts to the factory setting (or to the manufacturer setting, if you have set remote control codes).
Note
L;ALL and FCTRY may take about 30 seconds to complete.
OPERATION | ADVANCED |
|
|