■AUTO SETUP

TROUBLESHOOTING

AUTO SETUP

Before AUTO SETUP

Error message

Cause

Remedy

See

page

 

 

 

 

 

 

 

Connect MIC!

Optimizer microphone is not connected.

Connect the supplied optimizer microphone to the

30

OPTIMIZER MIC jack on the front panel.

 

 

 

 

 

 

 

Unplug HP!

Headphones are connected.

Unplug the headphones.

 

 

 

 

During AUTO SETUP

Error message

Cause

Remedy

See

page

 

 

 

 

 

 

 

E-1:NO FRONT SP

Front L/R channel signal(s) is (are) not

Select the front speakers with SPEAKER A or B.

 

 

detected.

Check the front L/R speaker connections.

13

 

 

 

 

 

 

 

E-2:NO SURR.SP

A surround channel signal is not detected.

Check the surround speaker connections.

13

 

 

 

 

E-3:NO PRNS SP

A presence channel signal is not detected.

Check the presence speaker connections.

13

 

 

 

 

 

Only right surround back channel signal is

Connect the surround back speaker to the LEFT

 

E-4:SBR->SBL

SURROUND BACK SPEAKERS terminal if you

13

detected.

 

only have one surround back speaker.

 

 

 

 

 

 

 

 

 

 

Try running AUTO SETUP in a quiet environment.

E-5:NOISY

Background noise is too loud.

 

 

Turn off noisy electric equipment like air conditioners

 

 

 

 

or move them away from the optimizer microphone.

 

 

 

 

 

 

 

 

Surround back speaker(s) is (are)

Connect surround speakers when you use (a)

 

E-6:CHECK SUR.

connected, though surround L/R speakers

13

surround back speaker(s).

 

are not.

 

 

 

 

 

 

 

 

E-7:NO MIC

The optimizer microphone was unplugged

Connect the supplied optimizer microphone to

30

during the AUTO SETUP procedure.

OPTIMIZER MIC jack on the front panel.

 

 

 

 

 

 

E-8:NO SIGNAL

The optimizer microphone does not detect

Check the microphone setting.

30

 

 

test tones.

Check the speaker connections and placement.

13

 

 

 

 

 

 

 

E-9:USER CANCEL

The AUTO SETUP procedure was

Run AUTO SETUP again.

30

cancelled due to user activity.

 

 

 

 

 

 

 

E-10:INTERNAL

An internal error occurred.

Run AUTO SETUP again.

30

ERROR

 

 

 

 

 

 

 