Routine Maintenance

Replace Fuse

Replace Fuse

The R110XiIIIPlus fuse must be replaced only by an authorized service technician.

Caution • Turn the AC power switch Off (O) and remove the power cord before performing this procedure.

The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is provided as a spare. The end caps of the fuse must bear the certification mark of a known international safety organization.

To replace a faulty fuse, complete these steps:

1.Use a small-blade screwdriver or similar tool to remove the fuse holder.

The fuse holder is part of the AC power entry module at the rear of the printer (Figure 45).

Figure 45 • AC Power Entry Module

1

2

3

4

1Power switch

2Fuse holder

3AC power entry module

4Small-blade screwdriver

2.Remove the faulty fuse and install a new fuse in the in-circuit position (Figure 46).

Important • If you use the spare fuse, be sure to order a replacement fuse from your authorized Zebra distributor. The spare fuse should be the exact type and rating as the original in-circuit fuse.

96

RXiIIIPlus User Guide

6/21/2004 23063L-001 Rev. 2