Printer Operation
Calibrate the Printer
Calibrate the PrinterThere are five different ways that the printer can be calibrated. You may calibrate the printer as needed.
•
•Long Calibration, which you select by pressing PAUSE then CALIBRATE, calibrates the printer for media length, media type (continuous or
•Short Calibration, which is a selection for the M E D I A P O W E R U P and H E A D C L O S E parameters, uses current sensor values rather than detecting the spaces between labels and resetting the sensors. This calibration sequence may use fewer labels than the long calibration sequence, but it is less reliable because the values that are stored in the sensors could be incorrect. For more information, see Media Power Up on page 54 or Head Close on page 54.
•Sensor Profile Calibration, which you select through the front panel,
•Media and Ribbon Sensor Sensitivity Calibration, which you select through the front panel, resets the sensitivity of the sensors to detect correctly the media and ribbon that you are using. See Media and Ribbon Sensor Calibration on page 34 for instructions. If you change the type of ribbon and/or media, you might need to reset the sensitivity of the media and ribbon sensors. When the sensors are at their new sensitivity, the printer performs an