Front Panel Controls

Front Panel LCD

 

Table 5 • Printer Parameters (Sheet 12 of 15)

 

 

Parameter

Action/Explanation

 

 

LABEL TOP

Adjusting Label Top Position

 

The label top position adjusts the print position vertically on the label. Positive numbers

 

adjust the label top position further down the label (away from the printhead), negative

 

numbers adjust the position up the label (toward the printhead).

 

The displayed value represents dots.

 

• To increase the value, press the right oval.

 

• To decrease the value, press the left oval.

 

Default: +0

 

Range: –120 to +120 dot rows

 

 

LEFT

Adjusting Left Position

POSITION

This parameter establishes how far from the left edge of a label the format begins to print

 

by adjusting horizontal positioning on the label. Positive numbers adjust the printing to the

 

left by the number of dots selected, negative numbers shift printing to the right.

 

The displayed value represents dots.

 

1. Press the left oval to move the cursor.

 

2. Press the right oval to change between + and to increase the value of the digit.

 

3. For a negative value, enter the value before changing to the minus sign.

 

Default: 0000

 

Range: –9999 to +9999

 

 

VERIFIER

Setting the Verifier Port

PORT

The auxiliary port is used to determine how the printer reacts to the online verifier. The

 

three operating conditions for this port are:

 

OFF: The verifier port is off.

 

VER-RPRNT ERR: Label reprinted if verifier detects an error. If a bar code is near

 

the upper edge of the label, the label is fed out far enough to be verified and then

 

backfed to allow the next label to print and be verified.

 

VER-THRUPUT:Allows greatest throughput but may not indicate a verification

 

error immediately upon detection. May print from one to three labels before an error

 

is recognized and printing stops.

 

• Press the right or left oval to display other choices.

 

Default: Off

 

Selections: Off, VER-RPRNT, VER-THRUPUT

 

For more information on the operation of the optional verifier, see the documentation

 

provided with that option.

 

 

23063L-001 Rev. 2 6/21/2004

RXiIIIPlus User Guide

55