Chapter 25 AAA

 

 

 

 

Table 73 Advanced Application > AAA > RADIUS Server Setup (continued)

 

LABEL

DESCRIPTION

 

Shared Secret

Specify a password (up to 32 alphanumeric characters) as the key to be shared between the

 

 

external RADIUS server and the Switch. This key is not sent over the network. This key must

 

 

be the same on the external RADIUS server and the Switch.

 

 

 

 

Delete

Select this box if you want to remove an existing RADIUS server entry from the Switch. This

 

 

entry is deleted when you click Apply.

 

 

 

 

Apply

Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these

 

 

changes if it is turned off or loses power, so use the Save link on the top navigation panel to

 

 

save your changes to the non-volatile memory when you are done configuring.

 

 

 

 

Cancel

Click Cancel to begin configuring this screen afresh.

 

 

 

 

AccountingUse this section to configure your RADIUS accounting server settings.

 

Server

 

 

 

 

 

Timeout

Specify the amount of time in seconds that the Switch waits for an accounting request

 

 

response from the RADIUS accounting server.

 

 

 

 

Index

This is a read-only number representing a RADIUS accounting server entry.

 

 

 

 

IP Address

Enter the IP address of an external RADIUS accounting server in dotted decimal notation.

 

 

 

 

UDP Port

The default port of a RADIUS accounting server for accounting is 1813. You need not change

 

 

this value unless your network administrator instructs you to do so.

 

 

 

 

Shared Secret

Specify a password (up to 32 alphanumeric characters) as the key to be shared between the

 

 

external RADIUS accounting server and the Switch. This key is not sent over the network.

 

 

This key must be the same on the external RADIUS accounting server and the Switch.

 

 

 

 

Delete

Check this box if you want to remove an existing RADIUS accounting server entry from the

 

 

Switch. This entry is deleted when you click Apply.

 

 

 

 

Apply

Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these

 

 

changes if it is turned off or loses power, so use the Save link on the top navigation panel to

 

 

save your changes to the non-volatile memory when you are done configuring.

 

 

 

 

Cancel

Click Cancel to begin configuring this screen afresh.

 

 

 

 

205