Chapter 8 Basic Setting

The following table describes the labels in this screen.

Table 13 Basic Setting > System Info

LABEL

DESCRIPTION

System Name

This field displays the descriptive name of the Switch for identification purposes.

 

 

Product ModelThis field displays the model number of the Switch.

 

 

ZyNOS F/W

This field displays the version number of the Switch 's current firmware including the date

Versioncreated.

 

 

Ethernet

This field refers to the Ethernet MAC (Media Access Control) address of the Switch.

Address

 

 

 

Hardware Monitor

 

 

Temperature

The Switch has temperature sensors that are capable of detecting and reporting if the

Unit

temperature rises above the threshold. You may choose the temperature unit (Centigrade or

 

Fahrenheit) in this field.

 

 

Temperature

BOARD, MAC and PHY refer to the location of the temperature sensors on the Switch

 

printed circuit board.

 

 

CurrentThis shows the current temperature at this sensor.

 

 

MAXThis field displays the maximum temperature measured at this sensor.

 

 

MINThis field displays the minimum temperature measured at this sensor.

 

 

ThresholdThis field displays the upper temperature limit at this sensor.

 

 

Status

This field displays Normal for temperatures below the threshold and Error for those above.

 

 

Fan Speed

A properly functioning fan is an essential component (along with a sufficiently ventilated,

(RPM)

cool operating environment) in order for the device to stay within the temperature

(ES3500-24HP

threshold. Each fan has a sensor that is capable of detecting and reporting if the fan speed

falls below the threshold shown.
only)

 

Current

This field displays this fan's current speed in Revolutions Per Minute (RPM).

 

 

MAX

This field displays this fan's maximum speed measured in Revolutions Per Minute (RPM).

 

 

MIN

This field displays this fan's minimum speed measured in Revolutions Per Minute (RPM).

 

"<41" is displayed for speeds too small to measure.

 

 

Threshold

This field displays the minimum speed at which a normal fan should work.

 

 

Status

Normal indicates that this fan is functioning above the minimum speed. Error indicates that

 

this fan is functioning below the minimum speed.

 

 

Voltage (V)

The power supply for each voltage has a sensor that is capable of detecting and reporting if

 

the voltage falls out of the tolerance range.

 

 

Current

This is the current voltage reading.

 

 

MAX

This field displays the maximum voltage measured at this point.

 

 

MIN

This field displays the minimum voltage measured at this point.

 

 

Threshold

This field displays the percentage tolerance of the voltage with which the Switch still works.

 

 

Status

Normal indicates that the voltage is within an acceptable operating range at this point;

 

otherwise Error is displayed.

 

 

 

85

ES3500 Series User’s Guide