Chapter 39 Access Control

 

 

 

 

Table 127 SNMP System Traps (continued)

 

OPTION

OBJECT LABEL

OBJECT ID

DESCRIPTION

poe

PwrPortFailedEventOn

ES3500-24HP:

This trap is sent when the port is

 

 

1.3.6.1.4.1.890.1.5.8.73.27.2.1

turned off to supply power due to

 

 

 

overloading over system budget, or

 

 

 

short circuit.

 

 

 

 

 

PwrPortFailedEventClear

ES3500-24HP:

This trap is sent when the port returns

 

 

1.3.6.1.4.1.890.1.5.8.73.27.2.2

to the normal state and has the ability

 

 

 

to supply power

 

 

 

 

 

PsePwrFailedEventOn

ES3500-24HP:

This trap is sent when the power

 

 

1.3.6.1.4.1.890.1.5.8.73.27.2.1

supply of PoE failed. The trigger

 

 

 

situation includes internal/external

 

 

 

power supply failure, external fan

 

 

 

speed failure and external power has

 

 

 

exceed normal temperature.

 

 

 

 

 

PsePwrFailedEventClear

ES3500-24HP:

This trap is sent when the power

 

 

1.3.6.1.4.1.890.1.5.8.73.27.2.2

supply of PoE returns to the normal

 

 

 

state.

 

 

 

 

temperature

TemperatureEventOn

ES3500-24:

This trap is sent when the temperature

 

 

1.3.6.1.4.1.890.1.5.8.61.27.2.1

goes above or below the normal

 

 

ES3500-8PD:

operating range.

 

 

 

 

 

1.3.6.1.4.1.890.1.5.8.72.27.2.1

 

 

 

ES3500-24HP:

 

 

 

1.3.6.1.4.1.890.1.5.8.73.27.2.1

 

 

 

 

 

 

TemperatureEventClear

ES3500-24:

This trap is sent when the temperature

 

 

1.3.6.1.4.1.890.1.5.8.61.27.2.2

returns to the normal operating range.

 

 

ES3500-8PD:

 

 

 

1.3.6.1.4.1.890.1.5.8.72.27.2.2

 

 

 

ES3500-24HP:

 

 

 

1.3.6.1.4.1.890.1.5.8.73.27.2.2

 

 

 

 

 

voltage

VoltageEventOn

ES3500-24:

This trap is sent when the voltage goes

 

 

1.3.6.1.4.1.890.1.5.8.61.27.2.1

above or below the normal operating

 

 

ES3500-8PD:

range.

 

 

 

 

 

1.3.6.1.4.1.890.1.5.8.72.27.2.1

 

 

 

ES3500-24HP:

 

 

 

1.3.6.1.4.1.890.1.5.8.73.27.2.1

 

 

 

 

 

 

VoltageEventClear

ES3500-24:

This trap is sent when the voltage

 

 

1.3.6.1.4.1.890.1.5.8.61.27.2.2

returns to the normal operating range.

 

 

ES3500-8PD:

 

 

 

1.3.6.1.4.1.890.1.5.8.72.27.2.2

 

 

 

ES3500-24HP:

 

 

 

1.3.6.1.4.1.890.1.5.8.73.27.2.2

 

 

 

 

 

 

295

ES3500 Series User’s Guide