TROUBLESHOOTING AND REPAIR | ||
|
Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
PROBLEMS
(SYMPTOMS)
No auxiliary power - welding output is normal - engine runs normally.
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
1.Check circuit breakers CB1 and CB2. Reset if tripped.
2.Make sure that the control rheo- stat (R1) is set at “GENERATOR” (maximum).
3.Check for loose or faulty plug at power receptacle.
RECOMMENDED
COURSE OF ACTION
1.Check the auxiliary power re- ceptacles and associated wires for loose or faulty connections.
2.Check the continuity (zero ohms) of leads 3, 3A (black); 6, 6A (yellow); and 5 (white) from the receptacles to the stator windings. See the Wiring Dia- gram.
3.Make sure lead 5 (white) is grounded to the machine frame (zero ohms).
4.Check for an open or grounded auxiliary winding in the stator, 6 (yellow) to 3 (black). See the Wiring Diagram.
Return to Section TOC
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call