Briggs & Stratton 206484GS manual Essential Circuits

Page 10

Essential Circuits

As a home generator owner, it is important that you clearly identify the circuits in your building that are “essential” to you.

It is also important that your installer understand which circuits you want to include as “Essential Circuits”. Depending on the power consumed by these circuits, most or all of them can be switched to the home generator for the duration of normal power interruption.

The wattage reference table that follows will assist you with your decision-making process. It provides the wattage used by many ordinary household devices. Use it as a guide when selecting your essential circuits. Review this information with your installer and ask about any technical considerations that might affect your installation. This chart serves as a guide only. For exact wattage use an appropriate wattage meter.

Essential Circuit Selection

When selecting the essential circuits that will be switched to “Standby Power,” it is important that the sum of the combined circuit loads does not exceed the wattage/ amperage capacity of the generator. To help you with your selection of essential circuits, please consider the following:

Add up the total wattage of all electrical devices to be connected at one time. This total should NOT be greater than the generator’s wattage capacity.

The rated wattage of lights can be taken from light bulbs. The rated wattage of tools, appliances and motors can usually be found on a data plate or decal affixed to the device.

If the appliance, tool or motor nameplate does not list wattage, multiply volts times the ampere rating to determine watts (Volts x Amps = Watts).

Some electric motors (induction types) require about three times more watts of power for starting than for running. This surge lasts for only a few seconds. Be sure you allow for this high starting wattage when selecting electrical devices that will be energized by the home generator:

Figure the watts required to start the largest motor.

Add that to the total running watts of all other connected loads.

This Briggs & Stratton home generator complies with the following “stationary standby power rating”:

The standby power rating is applicable for supplying power for the duration of normal power interruption. No sustained overload capability is available for this rating.

 

Device

Running Watts

 

 

 

q

Air Conditioner (12,000 Btu)*

1700

 

 

 

q

Air Conditioner (24,000 Btu)*

3800

q

Air Conditioner (40,000 Btu)*

6000

 

 

 

q

Battery Charger (20 Amp)

500

 

 

 

q

Circular Saw (6-1/2”)

800 to 1000

q

Clothes Dryer (Electric)*

5750

 

 

 

q

Clothes Dryer (Gas)*

700

 

 

 

q

Clothes Washer*

1150

q

Coffee Maker

1750

 

 

 

q

Compressor (1 HP)*

2000

 

 

 

q

Compressor (1/2 HP)*

1400

q

Compressor (3/4 HP)*

1800

 

 

 

q

Curling Iron

700

 

 

 

q

Dehumidifier*

650

q

Electric Blanket

400

 

 

 

q

Electric Range (per element)

1500

 

 

 

q

Electric Skillet

1250

q

Freezer*

700

 

 

 

q

Furnace Fan (1/2 HP)*

800

 

 

 

q

Garage Door Opener*

500 to 750

q

Hair Dryer

1200

 

 

 

q

Hand Drill

250 to 1100

 

 

 

q

Iron

1200

q

Jet Pump*

800

 

 

 

q

Light Bulb

100

 

 

 

q

Microwave Oven

700 to 1000

q

Milk Cooler*

1100

 

 

 

q

Oil Burner on Furnace

300

 

 

 

q

Oil Fired Space Heater (140,000 Btu)

400

q

Oil Fired Space Heater (30,000 Btu)

150

 

 

 

q

Oil Fired Space Heater (85,000 Btu)

225

 

 

 

q

Radio

50 to 200

q

Refrigerator

700

 

 

 

q

Slow Cooker

200

 

 

 

q

Submersible Pump (1 HP)*

2000

q

Submersible Pump (1/2 HP)*

1500

 

 

 

q

Submersible Pump (1-1/2 HP)*

2800

 

 

 

q

Sump Pump*

800 to 1050

q

Table Saw (10”)*

1750 to 2000

 

 

 

q

Television

200 to 500

 

 

 

q

Toaster

1000 to 1650

*Allow three (3) times listed watts for starting device

10

BRIGGSandSTRATTON.COM

Image 10
Contents Watt Home Generator System Engine Where to Find UsDate of Purchase Generator Model Number Model Revision Serial NumberTable of Contents Hazard Symbols and Meanings Safety RulesBRIGGSandSTRATTON.COM Page See Essential Circuits Installation Owner OrientationFuel Factors Lifting the GeneratorGenerator Location Home Generator LocationGeneral Location Guidelines Essential Circuits To Install Access Cover and Roof Access CoversTo Remove Access Cover Fuel and Electrical Inlet LocationsGaseous Fuel System Manometer port should be provided BRIGGSandSTRATTON.COMFuel Pipe Sizing Natural Gas LP VaporFuel Consumption 10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ftGas Fuel Comparison ChartLP Vapor Natural Required Propane Tank SizePole Connector Plug System Connectors+12 Volt DC, .5 Amp Output Internal auxiliary power supply To install the remote LED indicator Transfer Switch CommunicationFault Detection System Generator AC Connection SystemFinal Installation Considerations Initial Start-up No LoadHome Generator Features and ControlsUnit Identification Label Identifies unit by serial number System Control Panel Automatic Operation Sequence OperationAutomatic Operation Setting Exercise Timer Fault Detection System MaintenanceServicing the System Low Voltage Generator High TemperatureTransfer Switch Fault Engine Fail To StartGenerator Maintenance Charging the Battery BatteryServicing the Battery When Calling the Factory To Clean the GeneratorStorage Down when loads are connected TroubleshootingProblem Cause Correction AvailableSchematic Wiring Diagram Limited Warranty Page At 120 Volts Product SpecificationsCommon Service Parts At 240 VoltsWatt Motor Dónde encontrarnosFecha de compra Generador Número de Modelo Revisión Número de SerieInstalación Problemas Garantía Especificaciones del productoReglas de seguridad Controles y característicasReglas de seguridad Símbolos de Peligro y SignificadosTensión peligrosa Ate para arriba el pelo largo y quite la joyeríaInstala el fusible se puede producir el arranque del motor No modifique al generador en ninguna formaInstalación Orientación para el propietarioPrecauciones al Momento del Desempaque Factores Relacionados con el CombustibleInspección al Momento de la Entrega Ubicación del Generador Elevación del GeneradorUbicación del Sistema de Generador de Doméstico Pautas Generales para la Ubicación del GeneradorCircuitos Fundamentales Selección de los Circuitos FundamentalesDispositivo Vatiaje de Puertas de Acceso Dimensiones de la Entrada para Electricidad y CombustibleSistema de combustible gaseoso Se debe contar también con una abertura para manómetro Gas Natural Vapor de PL Vapor de GasCableado para toma bipolar Conexiones de SistemaCableado para toma de 10 polos Interconexiones del Circuito de Control Sistema de Conexión de c.a. del GeneradorConexión a Tierra del Generador Comunicación del conectadorConsideraciones finales para la instalación Instale el fusible de 15 Amperios en el panel de control Arranque inicial sin cargaInspección posterior a la instalación Ajustes. Conserve este manual para referencias futuras Controles y característicasGenerador Doméstico Calcomanía de Datos de la Unidad Identifica a laPanel de control del sistema Funcionamiento Automático UtilizaciónSecuencia de operación automática Temporizador de enfriamiento del motorConfiguración del temporizador de práctica Paro del Sistema MantenimientoSistema de Detección de Fallas Baja Frecuencia Baja TensiónEl Motor no Arranca Sobrevelocidad del MotorMantenimiento del Generador Cargar la Batería BateríaServicio la Batería Para Limpiar el Generador AlmacenamientoSi Llama a la Fábrica Problemas Problemas Causa CorrecciónGarantía Limitada Especificaciones del producto Servicio común despideWatt Groupe électrogène Moteur Où nous trouverDate d’achat Génératrice Numéro de modèle Révision Numéro de sérieFonctionnement Fonctions et commandesRègles de sécurité EntreitenSécurité Symboles de Danger et MoyensRègles de sécurité Certains composants de ce produit ainsi que lesTension dangereuse Avis Conservez ces instructions Responsabilités de l’installateurConseils au propriétaire Responsabilités de l’acheteurPrécautions lors du déballage Facteurs relatifs au combustibleVérification de la livraison Installez l’unité à l’extérieur Seulement Emplacement du génératrice d’état d’attenteDirectives générales concernant l’emplacement Soulèvement de la génératrice10 Circuits essentiels’illustration suivante montre les dégagements Minimum Sélection des circuits essentielsDéshumidificateur Scie circulaire 6,5 po 16,5 cmSécheuse électrique 750 Sécheuse gaz Couverture électriqueLe système de combustible gazeux Pour installer la porte d’accès et le toitPortes d’accès Pour enlever le toitAucune fuite ne peut être tolérée Il faudrait inclure une sortie pour manomètreGas Naturel Vapeur PL Propane GazConnexions de système Niveau de la génératrice Interconnexions du Circuit de CommandeSécurité Système de Branchement C.A. de la Génératrice Mise à la Masse de la GénératriceConsidérations pour l’installation finale Vérification installation Démarrage initial sans chargeSécurité Instalación Commandes Fonctionnement Fonctions et commandesEntretien Dépannage Garantie Tableau de commande de système Sécurité Instalación CommandesSéquence de fonctionnement automatique FonctionnementFonctionnement automatique Système de Détection des Pannes EntreitenArrêt du Système Code de Nombre deFaible Pression d’Huile Aucun DEL Batterie déchargéeFaible Tension de la Batterie Basse TensionEntretien du Générateur Pour mettre de l’huile dans le moteur BatterieChangement du filtre à huile Filtre à airPour Nettoyer le Générateur RemisageEntretien de la Batterie 26Problème Cause Solution DépannageGarantie Limitée Page Caractéristiques du produit Pièces d’entretien courant