Briggs & Stratton 206484GS manual Generator Maintenance

Page 24

Generator Maintenance

The generator warranty does not cover items that have been subjected to operator abuse or neglect. To receive full value from the warranty, the operator must maintain the system as instructed in the engine operator’s manual.

All adjustments should be made at least once each season. Follow the requirements in the engine operator’s manual.

Generator maintenance consists of keeping the unit clean. Operate the unit in an environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air louvers on the enclosure must not become clogged with snow, leaves, or any other foreign material. To prevent generator damage caused by overheating, keep the enclosure cooling inlets and outlets clean and unobstructed at all times.

Check the cleanliness of the unit frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior/interior surface. Inspect the air inlet and outlet openings inside and outside the enclosure to ensure air flow is not blocked.

NOTE: DO NOT use direct spray from a garden hose to clean generator. Water can enter the engine and generator and cause problems.

Engine Oil

The system is filled with synthetic oil (API SJ/CF 5W-30W). This allows for system operation in the widest range of temperature and climate conditions.

NOTE: The use of synthetic oil does not alter the required oil change intervals described in the engine operator’s manual.

Changing Engine Oil and Filter

Remove the two screws from each plastic access cover and remove both access covers from the two sides of the generator enclosure.

Changing Oil

1.Place the oil drain tube into an approved container.

2.Remove brass plug from tube opposite of engine.

3.When the oil has drained, replace brass plug into tube.

4.Slide the oil drain tube up into the beaded tie wrap on the fuel hose.

Changing Oil Filter

1.Place oil drain tray over tubing and slide it under oil filter.

2.Follow instructions given in engine operator’s manual for changing oil filter.

3.Remove oil drain tray from under oil filter and clean up any spilled oil.

caution

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON’T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

To fill your engine with oil:

Follow the synthetic oil grade recommendation and oil fill instructions given in the engine operator’s manual.

notice

Any attempt to crank or start the engine before it has been properly serviced with the recommended oil will result in equipment failure.

Refer to Maintenance and engine manual for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void engine and generator warranty.

Air Filter

The engine for this generator is equipped with a UL recognized air filter. When servicing the air filter, follow the instructions given in the engine operators manual. Replace ONLY with same type UL recognized air filter, P/N 790263.

24

BRIGGSandSTRATTON.COM

Image 24
Contents Watt Home Generator System Where to Find Us Date of Purchase GeneratorEngine Model Number Model Revision Serial NumberTable of Contents Safety Rules Hazard Symbols and MeaningsBRIGGSandSTRATTON.COM Page See Essential Circuits Installation Owner OrientationFuel Factors Lifting the GeneratorHome Generator Location Generator LocationGeneral Location Guidelines Essential Circuits Access Covers To Remove Access CoverTo Install Access Cover and Roof Fuel and Electrical Inlet LocationsGaseous Fuel System Manometer port should be provided BRIGGSandSTRATTON.COMNatural Gas LP Vapor Fuel ConsumptionFuel Pipe Sizing 10ft 15ft 20ft 30ft 40ft 50ft 60ft 70ft 80ft 90ft 100ftFuel Comparison Chart LP Vapor NaturalGas Required Propane Tank SizeSystem Connectors Pole Connector Plug+12 Volt DC, .5 Amp Output Internal auxiliary power supply Transfer Switch Communication Fault Detection SystemTo install the remote LED indicator Generator AC Connection SystemFinal Installation Considerations Initial Start-up No LoadFeatures and Controls Home GeneratorUnit Identification Label Identifies unit by serial number System Control Panel Operation Automatic Operation SequenceAutomatic Operation Setting Exercise Timer Maintenance Fault Detection SystemServicing the System High Temperature Transfer Switch FaultLow Voltage Generator Engine Fail To StartGenerator Maintenance Battery Charging the BatteryServicing the Battery To Clean the Generator When Calling the FactoryStorage Troubleshooting Problem Cause CorrectionDown when loads are connected AvailableSchematic Wiring Diagram Limited Warranty Page Product Specifications Common Service PartsAt 120 Volts At 240 VoltsWatt Dónde encontrarnos Fecha de compra GeneradorMotor Número de Modelo Revisión Número de SerieProblemas Garantía Especificaciones del producto Reglas de seguridadInstalación Controles y característicasReglas de seguridad Símbolos de Peligro y SignificadosTensión peligrosa Ate para arriba el pelo largo y quite la joyeríaInstala el fusible se puede producir el arranque del motor No modifique al generador en ninguna formaInstalación Orientación para el propietarioFactores Relacionados con el Combustible Precauciones al Momento del DesempaqueInspección al Momento de la Entrega Elevación del Generador Ubicación del Sistema de Generador de DomésticoUbicación del Generador Pautas Generales para la Ubicación del GeneradorCircuitos Fundamentales Selección de los Circuitos FundamentalesDispositivo Vatiaje de Dimensiones de la Entrada para Electricidad y Combustible Puertas de AccesoSistema de combustible gaseoso Se debe contar también con una abertura para manómetro Gas Natural Vapor de PL Vapor de GasConexiones de Sistema Cableado para toma bipolarCableado para toma de 10 polos Sistema de Conexión de c.a. del Generador Conexión a Tierra del GeneradorInterconexiones del Circuito de Control Comunicación del conectadorConsideraciones finales para la instalación Arranque inicial sin carga Instale el fusible de 15 Amperios en el panel de controlInspección posterior a la instalación Controles y características Generador DomésticoAjustes. Conserve este manual para referencias futuras Calcomanía de Datos de la Unidad Identifica a laPanel de control del sistema Utilización Secuencia de operación automáticaFuncionamiento Automático Temporizador de enfriamiento del motorConfiguración del temporizador de práctica Mantenimiento Paro del SistemaSistema de Detección de Fallas Baja Tensión El Motor no ArrancaBaja Frecuencia Sobrevelocidad del MotorMantenimiento del Generador Batería Cargar la BateríaServicio la Batería Almacenamiento Para Limpiar el GeneradorSi Llama a la Fábrica Problemas Problemas Causa CorrecciónGarantía Limitada Especificaciones del producto Servicio común despideWatt Groupe électrogène Où nous trouver Date d’achat GénératriceMoteur Numéro de modèle Révision Numéro de sérieFonctions et commandes Règles de sécuritéFonctionnement EntreitenSymboles de Danger et Moyens Règles de sécuritéSécurité Certains composants de ce produit ainsi que lesTension dangereuse Avis Responsabilités de l’installateur Conseils au propriétaireConservez ces instructions Responsabilités de l’acheteurFacteurs relatifs au combustible Précautions lors du déballageVérification de la livraison Emplacement du génératrice d’état d’attente Directives générales concernant l’emplacementInstallez l’unité à l’extérieur Seulement Soulèvement de la génératriceCircuits essentiels ’illustration suivante montre les dégagements Minimum10 Sélection des circuits essentielsScie circulaire 6,5 po 16,5 cm Sécheuse électrique 750 Sécheuse gazDéshumidificateur Couverture électriquePour installer la porte d’accès et le toit Portes d’accèsLe système de combustible gazeux Pour enlever le toitAucune fuite ne peut être tolérée Il faudrait inclure une sortie pour manomètreGas Naturel Vapeur PL Propane GazConnexions de système Interconnexions du Circuit de Commande Sécurité Système de Branchement C.A. de la GénératriceNiveau de la génératrice Mise à la Masse de la GénératriceConsidérations pour l’installation finale Vérification installation Démarrage initial sans chargeFonctions et commandes Sécurité Instalación Commandes FonctionnementEntretien Dépannage Garantie Tableau de commande de système Sécurité Instalación CommandesFonctionnement Séquence de fonctionnement automatiqueFonctionnement automatique Entreiten Arrêt du SystèmeSystème de Détection des Pannes Code de Nombre deAucun DEL Batterie déchargée Faible Tension de la BatterieFaible Pression d’Huile Basse TensionEntretien du Générateur Batterie Changement du filtre à huilePour mettre de l’huile dans le moteur Filtre à airRemisage Entretien de la BatteriePour Nettoyer le Générateur 26Problème Cause Solution DépannageGarantie Limitée Page Caractéristiques du produit Pièces d’entretien courant