Table 34 shows the thermal characteristics of the 25 mm × 25 mm BGA_ED package. All parameters are based on a
Table 34. Thermal Characteristics for 25 mm × 25 mm Package
Parameter | Condition | Typical | Unit |
θJA1 | Airflow = 0 m/s | 12.92 | °C/W |
| Airflow = 1 m/s | 10.2 | °C/W |
| Airflow = 2 m/s | 9.0 | °C/W |
| Airflow = 3 m/s | 8.0 | °C/W |
θJB3 | — | 7.7 | °C/W |
θJC4 | — | 0.7 | °C/W |
1θJA measured per JEDEC standard
2θJA = 12.9°C/W for 0 m/s is for vertically mounted boards. For horizontally mounted boards, use 17.0°C/W for 0 m/s.
3θJB measured per JEDEC standard
4θJC measured by cold plate test method (no approved JEDEC standard).