CY7C67200
Table 41.DC Characteristics: Charge Pump (continued)
Parameter | Description | Conditions | Min. | Typ. | Max. | Unit |
VA_SESS_VALID |
| 0.8 |
| 2.0 | V | |
VB_SESS_VALID |
| 0.8 |
| 4.0 | V | |
VA_SESS_END |
| 0.2 |
| 0.8 | V | |
E | Efficiency When Loaded | ILOAD = 8 mA, VCC = 3.3V |
| 75 |
| % |
RPD | Data Line Pull Down |
| 14.25 |
| 24.8 | Ω |
RA_BUS_IN | VBUS is not being driven | 40 |
| 100 | kΩ | |
| to GND |
|
|
|
|
|
RB_SRP_UP | 281 |
|
| Ω | ||
RB_SRP_DWN |
| 656 |
|
| Ω |
USB Transceiver
USB
This product was tested as compliant to the
AC Timing Characteristics
Reset Timing
tRESET
nRESET
nRD or nWRL or nWRH
tIOACT
Reset Timing
Parameter | Description | Min. | Typ. | Max. | Unit |
tRESET | nRESET Pulse Width | 16 |
|
| clocks[9] |
tIOACT | nRESET HIGH to nRD or nWRx Active | 200 |
|
| µs |
Note
9. Clock is 12 MHz nominal.
Document #: | Page 67 of 78 |
[+] Feedback