CY7C67200
Receive Full (Bit 1)
The Receive Full bit indicates whether the receive buffer is full. It can be programmed to interrupt the CPU as interrupt #5 when the buffer is full. This can be done though the UART bit of the Interrupt Enable register (0xC00E). This bit will automat- ically be cleared when data is read from the UART Data register.
1:Receive buffer full
0:Receive buffer empty
Transmit Full (Bit 0)
The Transmit Full bit indicates whether the transmit buffer is full. It can be programmed to interrupt the CPU as interrupt #4 when the buffer is empty. This can be done though the UART bit of the Interrupt Enable register (0xC00E). This bit will automatically be set to ‘1’ after data is written by
1:Transmit buffer full (transmit busy)
0:Transmit buffer is empty and ready for a new byte of data
UART Data Register [0xC0E4] [R/W]
Figure 75. UART Data Register
Bit # | 15 | 14 | 13 | 12 |
| 11 | 10 | 9 | 8 |
Field |
|
|
|
| Reserved |
|
|
| |
Read/Write | - | - | - | - |
| - | - | - | - |
Default | 0 | 0 | 0 | 0 |
| 0 | 0 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
Bit # | 7 | 6 | 5 | 4 |
| 3 | 2 | 1 | 0 |
Field |
|
|
|
| Data |
|
|
| |
Read/Write | R/W | R/W | R/W | R/W |
| R/W | R/W | R/W | R/W |
Default | 0 | 0 | 0 | 0 |
| 0 | 0 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
Register Description
The UART Data register contains data to be transmitted or received from the UART port. Data written to this register will start a data transmission and also causes the UART Transmit Empty Flag of the UART Status register to set. When data received on the UART port is read from this register, the UART Receive Full Flag of the UART Status register will be cleared.
Data (Bits [7:0])
The Data field is where the UART data to be transmitted or received is located
Reserved
All reserved bits must be written as ‘0’.
Document #: | Page 62 of 78 |