SPRS292A − OCTOBER 2005 − REVISED NOVEMBER 2005
absolute maximum ratings over operating case temperature range (unless otherwise noted)†
Supply voltage range, CVDD (see Note 2) | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . . . − 0.3 V to 1.8 | V |
Supply voltage range, DVDD (see Note 2) | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . . . . . −0.3 V to 4 | V |
Input voltage range | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to DV DD + 0.5 V | ||
Output voltage range | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to DV DD + 0.5 V | ||
Operating case temperature ranges, TC | (default) | . . . . . . 0_C to 90_C | |
| (A version) [C6711DGDPA and C6711DZDPA] | . . . −40 _C to105_C | |
Storage temperature range, Tstg | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | . . . −65 _C to 150_C |
†Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to
NOTE 2: All voltage values are with respect to VSS.
recommended operating conditions‡
|
|
|
|
|
|
| MIN | NOM | MAX | UNIT |
|
|
|
|
|
|
|
|
|
|
|
CVDD | Supply voltage, Core | −250 only | 1.33 | 1.4 | 1.47 | V | ||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 1.14§ | 1.20§ | 1.32 | V | ||
DVDD | Supply voltage, I/O |
|
|
|
|
| 3.13 | 3.3 | 3.47 | V |
VSS | Supply ground |
|
|
|
|
| 0 | 0 | 0 | V |
VIH | All signals except CLKS1, DR1, and | RESET |
| 2 |
|
| V | |||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |||
CLKS1, DR1, and RESET | 2 |
|
| |||||||
|
|
|
|
| ||||||
|
|
|
|
|
|
| ||||
|
| All signals except CLKS1, DR1, and |
|
|
|
| 0.8 |
| ||
VIL | RESET |
|
|
| V | |||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |||
CLKS1, DR1, and RESET |
|
| 0.3*DVDD | |||||||
|
|
|
|
| ||||||
|
| All signals except ECLKOUT, CLKOUT2, CLKS1, and |
|
|
| |||||
IOH | DR1 |
|
| mA | ||||||
|
|
| ||||||||
|
| ECLKOUT and CLKOUT2 |
|
|
| |||||
|
|
|
|
|
|
| ||||
|
| All signals except ECLKOUT, CLKOUT2, CLKS1, and |
|
| 8 | mA | ||||
|
| DR1 |
|
| ||||||
|
|
|
|
| ||||||
I |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
OL |
| ECLKOUT and CLKOUT2 |
|
| 16 | mA | ||||
|
|
|
| |||||||
|
| CLKS1 and DR1 |
|
| 3 | mA | ||||
|
|
|
|
|
|
|
|
|
|
|
TC | Operating case | Default | 0 |
| 90 | _C | ||||
temperature |
| |||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||||
V | Maximum voltage during overshoot (See Figure 19) |
|
| 4# | V | |||||
OS |
|
|
|
|
|
|
|
|
|
|
V | Maximum voltage during undershoot (See Figure 20) |
|
| −0.7 # | V | |||||
US |
|
|
|
|
|
|
|
|
|
|
TC | Operating case | A version (C6711DGDPA and C6711DZDPA) |
| 105 | _C | |||||
temperature |
| |||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
‡The core supply should be powered up prior to (and powered down after), the I/O supply. Systems should be designed to ensure that neither supply is powered up for an extended period of time if the other supply is below the proper operating voltage.
§These values are compatible with existing 1.26−V designs.
¶Refers to DC (or steady state) currents only, actual switching currents are higher. For more details, see the
# The absolute maximum ratings should not be exceeded for more than 30% of the cycle period.