Sharp SRT-8960 Normal Recording, Record Pause, Recording Check, Pause/still indicator N flashes

Page 21

RF4QR/NA (SRT-8960 GB) Wed. May, 08/2002

NORMAL RECORDING

Record Pause

Recording can be interrupted temporarily.

1Press the STILL/PAUSE button during recording.

øThe pause/still indicator Nflashes.

NOTES:

œThe image appears on-screen but it is not recorded.

œIf a recording pause continues for 5 minutes or more, the VCR will switch to stop mode to avoid damaging the tape.

2To resume recording, press the REC button, or press the STILL/PAUSE button again.

Recording Check

The image being recorded can be checked.

1During recording, press the REC CHECK button.

øThe tape will be rewound and then played back. The VCR will then return to the previous recording mode.

NOTE:

œDuring recording check operations, recording is suspended momentarily.

Concerning the Number of Times Tapes can be Rerecorded on

Depending on the recording speed mode, the tape must be replaced after a certain number of recording times.

Refer to the table below for the maximum number of times a tape can be recorded on.

Recording speed mode

Maximum number of

(hour mode)

recording times

 

 

(with a standard grade

 

 

tape)

6,

8

100

 

 

 

18,

24

50

 

 

 

30,

40

50

 

 

 

48,

64

25

 

 

 

72,

96

10

 

 

96, 128

6

 

 

 

120,

160

5

 

 

 

168,

224

3

 

 

 

240,

320

3

 

 

 

360,

480

3

 

 

 

480,

640

2

 

 

720

1

 

 

960

1

 

 

000

1

 

 

 

NOTES:

œThe maximum number of recording times will vary depending on the location and kind of tape used. Verify the recording quality and replace the tape when the quality starts to deteriorate.

The maximum number of recording times indicated above are based on test tapes (T-120 and T-160) used by the company.

œIt is recommended that tape be changed at least as often as in the above table to provide good picture quality in the mode above.

20

English

Image 21
Contents SRT-8960 SRT-8168 SRT-8040 For customers in Canada PrecautionsMoisture Condensation Problems PrecautionsLocation Avoiding Electrical Shock and FireContents FeaturesAccessory Front Panel Locations of Controls and IndicatorsOperation Indicators Locations of Controls and IndicatorsOperation Mode Indicator Digital DisplayWith the RS-485/232C interface board B C D Back Panel With the RS-485/232C interface boardConnections Power Cord InstallationON-SCREEN Menu Using the JOG dial and Shuttle ring for settingsMain Menu Sub-menusON-SCREEN Menu Setting the Language and Clock Language SettingClock setting Setting the Language and Clock Automatic Daylight Saving Time AdjustmentFactory setting Superimpose Display Selecting the Superimpose DisplayChanging the Superimpose Display Position Video Cassette Tapes Setting the Type of Tape Used Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes Correct tape thread check functionOperation Tape ManagementIf no tape management data is present on the tape If tape management data is present on the tapeSetting the Tape Management Function Tape ManagementTape Management menu appears Conflict display sample Tape Management Conflict DisplayNormal Recording Recording Speed ModeNormal Recording Before startingNormal Recording Pause/still indicator N flashesRecord Pause Recording CheckSetting the clog detection Action to Take when the Video Signal DeterioratesClog Detection Setting the video input signal Setting the Mode at the End of the TapeSetting when not using Autorepeat recording Setting when using Autorepeat recordingRepeat indicator lights Autorepeat RecordingAutorepeat Recording Alarm Recording Alarm Recording SettingALARM/SERIES REC SET menu appears Alarm Recording Reset Function Alarm RecordingAlarm Recording Counter Display Connections to the Alarm in TerminalAlarm Scan Alarm SearchProgram Timer Recording Timer SET menu appears Program Timer RecordingChanging a Program Timer Recording Setting the HolidaysTo Cancel a Program Timer Recording To cancel all program timer recordingsThese portions will not be recorded Recording Using AN External Timer Input Series Recording Series Recording SetupOperation Loop recordingSingle Image Recording Single Image Recording SetupNormal Playback Special Playback Shuttle Ring Operation Special PlaybackDAY/TIME Search Tape CounterDay/Time Search Cancel the 4 digit security lock Setting the 4 digit security lockSecurity Lock Quick Method Security LockClock Adjustment Selecting Input and Output TerminalsConnection Cassette Eject Setup Setting the Cassette Eject ModeEject output Timer OUT terminal Eject input Series in terminalSynchronization Control Operator ModeAdministrator/Installer Mode Setting the Cassette Eject ModeSynchronization Control SC will flash on the digital displaySetting for RS-485 or RS-232C USE Setting the Address and Data Transfer SpeedSettings when using RS-485 Power FAILURE/DEW/USED Time menu appears Tape END OUT Terminal Output Setting Timer OUT terminalOutput Terminals Tape END OUT TerminalSW OUT Terminal Output Setting Output TerminalsSW OUT Terminal ALARM@@@@@@@@@@@@Y NON@REC@@@@@@@@@@N Remote Jack Remote control settingMaintenance Maintenance Maintenance TableMaintaining and Checking The Mechanism Troubleshooting Guide After a Power FailureSystem Down General Specifications SpecificationsConnectors VideoSpecifications Other SpecificationsConnectors When the Terminal SET is set to SET2 Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR Warranty