Sharp SRT-8040 Setting for RS-485 or RS-232C USE, Setting the Address and Data Transfer Speed

Page 44

RF4QR/NA (SRT-8960 GB) Wed. May, 08/2002

SETTING FOR RS-485 OR RS-232C USE

The RS-485 interface can be used to operate the VCR using a SANYO brand system controller. Furthermore, the RS-232C interface can be used to operate the VCR using a computer.

NOTES:

œThis can only be used when the RS-485/232C interface board (VZU-485/232C) is installed.

œRefer to the instruction manuals for the VZU-485/232C, the system controller and/or the computer.

Setting the Address and Data Transfer Speed

œMake this setting without a cassette tape inserted.

1Press the COUNTER RESET button for 3 seconds or more.

ø“485” or “232” appears on the digital display.

2Turn the JOG dial to select the interface being used, RS-232C or RS-485.

ø“232” or “485” appears on the digital display.

œWhen setting “232”, carry out step 3 and then step 6.

3Turn the SHUTTLE ring clockwise.

4Turn the JOG dial to set the VCR address (from 000 to 127).

øThe address set appears on the digital display.

5Turn the SHUTTLE ring clockwise.

6Turn the JOG dial to set the data transfer speed (19200, 2400, 4800, 9600).

øThe data transfer speed set appears on the digital display.

7When finished, Press the COUNTER RESET button.

NOTE:

œWhen the MENU RESET button is pressed, the setting appearing on the digital display is reset to the default setting.

Settings when using RS-485

1Press the MENU button to display the MAIN MENU.

2Turn the JOG dial to select the “9.OTHERS” line, then turn the SHUTTLE ring clockwise.

øThe (OTHERS) menu appears.

<OTHERS>

*ALARM@LOG

*POWER@FAILURE/DEW

*TERMINAL@SET@@@@SET1 *RS-485@SET @@STATUS@INFO.@@@Y @@ALARM@INFO.@@@@Y

3Turn the JOG dial until the “STATUS INFO.” setting is highlighted, then turn the SHUTTLE ring clockwise.

4Turn the JOG dial to set the “STATUS INFO.” setting, then turn the SHUTTLE ring clockwise.

Y. . . . . . . . . . The VCR status information is output at the RS-485 connector.

N. . . . . . . . . The status information is not output at the RS-485 connector.

5Turn the JOG dial until the “ALARM INFO.” setting is highlighted, then turn the SHUTTLE ring clockwise.

6Turn the JOG dial to set the “ALARM INFO.” setting, then turn the SHUTTLE ring clockwise.

Y. . . . . . . . . . The VCR alarm information (alarm recording start and stop) and video loss information are output at the RS-485 connector.

N. . . . . . . . . The VCR alarm information (alarm recording start and stop) and video loss information are not output at the RS-485 connector.

7Press the MENU EXIT button.

8Set the TERMINATE switch on the back panel to the “ON” or “OFF” position

OFF side . . . Not terminated

ON side . . . . Terminated

NOTE:

œWhen a warning state (non-recording, mechanical problem or clog detection) occurs, the warning state is output from the RS-485 connector. However, non-recording warning states are not output if “NON REC” is set to “N” in the (WARNING OUT/CONTROL SET) menu. In addition, the clog detection warning state is not output if “CLOG DETECT.” is set to “N” in the (GENERAL SET) menu.

English

43

Image 44
Contents SRT-8960 SRT-8168 SRT-8040 Precautions For customers in CanadaPrecautions Moisture Condensation ProblemsLocation Avoiding Electrical Shock and FireAccessory ContentsFeatures Locations of Controls and Indicators Front PanelLocations of Controls and Indicators Operation IndicatorsOperation Mode Indicator Digital DisplayWith the RS-485/232C interface board Back Panel With the RS-485/232C interface board B C DPower Cord Installation ConnectionsUsing the JOG dial and Shuttle ring for settings ON-SCREEN MenuMain Menu Sub-menusON-SCREEN Menu Clock setting Setting the Language and ClockLanguage Setting Factory setting Setting the Language and ClockAutomatic Daylight Saving Time Adjustment Changing the Superimpose Display Position Superimpose DisplaySelecting the Superimpose Display Video Cassette Tapes Setting the Action to Take When a Cassette is Loaded Setting the Type of Tape UsedVideo Cassette Tapes Correct tape thread check functionTape Management OperationIf no tape management data is present on the tape If tape management data is present on the tapeTape Management menu appears Setting the Tape Management FunctionTape Management Tape Management Conflict Display Conflict display sampleRecording Speed Mode Normal RecordingNormal Recording Before startingPause/still indicator N flashes Normal RecordingRecord Pause Recording CheckClog Detection Setting the clog detectionAction to Take when the Video Signal Deteriorates Setting the Mode at the End of the Tape Setting the video input signalSetting when not using Autorepeat recording Setting when using Autorepeat recordingAutorepeat Recording Repeat indicator lightsAutorepeat Recording ALARM/SERIES REC SET menu appears Alarm RecordingAlarm Recording Setting Alarm Recording Alarm Recording Reset FunctionAlarm Recording Counter Display Connections to the Alarm in TerminalAlarm Search Alarm ScanProgram Timer Recording Program Timer Recording Timer SET menu appearsSetting the Holidays Changing a Program Timer RecordingTo Cancel a Program Timer Recording To cancel all program timer recordingsThese portions will not be recorded Recording Using AN External Timer Input Series Recording Setup Series RecordingOperation Loop recordingSingle Image Recording Setup Single Image RecordingNormal Playback Special Playback Special Playback Shuttle Ring OperationDay/Time Search DAY/TIME SearchTape Counter Setting the 4 digit security lock Cancel the 4 digit security lockSecurity Lock Quick Method Security LockConnection Clock AdjustmentSelecting Input and Output Terminals Setting the Cassette Eject Mode Cassette Eject SetupEject output Timer OUT terminal Eject input Series in terminalOperator Mode Synchronization ControlSetting the Cassette Eject Mode Administrator/Installer ModeSynchronization Control SC will flash on the digital displaySettings when using RS-485 Setting for RS-485 or RS-232C USESetting the Address and Data Transfer Speed Power FAILURE/DEW/USED Time menu appears Timer OUT terminal Tape END OUT Terminal Output SettingOutput Terminals Tape END OUT TerminalSW OUT Terminal SW OUT Terminal Output SettingOutput Terminals ALARM@@@@@@@@@@@@Y NON@REC@@@@@@@@@@N Remote control setting Remote JackMaintenance Maintaining and Checking The Mechanism MaintenanceMaintenance Table System Down Troubleshooting GuideAfter a Power Failure Specifications General SpecificationsConnectors VideoConnectors When the Terminal SET is set to SET2 SpecificationsOther Specifications Sanyo Industrial VCR Warranty Weekdays 830 AM 500 PM Pacific Time