SPECIFICATIONS

General Specifications

Video head system

Dual-azimuth 4-head rotating helical scanning system:

 

Dual azimuth 2-head for record and standard playback

 

Dual azimuth 4-head for forward picture search, reverse picture search

 

and still mode

Audio recording

In 8-, 24- and 40-hour modes (when using T-160 tape)

 

In 6-, 18- and 30-hour modes (when using T-120 tape)

Tape speed

11.12 mm /sec (8-hour mode)

Specified video cassette tape

VHS 1/2 inch video cassette tape

Recording/playback time (SRT-8960 only)

8, 24, 40, 64, 96, 128, 160, 224, 320, 480, 640, 960 and 1280 hours (when

 

using T-160 tape)

 

6, 18, 30, 48, 72, 96, 120, 168, 240, 360, 480, 720 and 960 hours (when

 

using T-120 tape)

Recording/playback time (SRT-8168 only)

8, 24, 40, 64, 96, 128, 160 and 224 hours (when using T-160 tape)

 

6, 18, 30, 48, 72, 96, 120 and 168 hours (when using T-120 tape)

Recording/playback time (SRT-8040 only)

8, 24 and 40 hours (when using T-160 tape)

 

6, 18 and 30 hours (when using T-120 tape)

Fast forward/rewind time

approximately 2 minutes 35 seconds (when using T-160 tape)

 

approximately 2 minutes (when using T-120 tape)

Television system

NTSC color TV system

Video

Recording method

Luminance signal: FM recording

 

Chrominance signal: Down-converted direct recording

Video input

1 V(p-p), BNC, 75 , unbalanced

Video output

1 V(p-p), BNC, 75 , unbalanced

Horizontal resolution

Black & white mode

350 line or more

 

Color mode

300 line or more

Audio

Input

–8 dBs, RCA pin jack, 27 k, unbalanced

Output

–8 dBs, RCA pin jack, 600 , unbalanced

Connectors

Alarm (1 shot) input

No voltage, make-contact switch input (Low input 100ms or more,

 

Normally 5 V)

Control input

Key code (pulse signal) (Normally 5 V)

Series input

No voltage, make-contact switch input (Low input 1s or more, Normally 5 V)

Ext timer (alarm reset) input

No voltage, make-contact switch input (Low input 100ms or more,

 

Normally 5 V)

Common

0 V (GND)

Warning output

Open collector Max. 500 mA (Active Low 0 V, Normally open)

Control output

Key code (pulse signal) (Normally 5 V)

Tape end output

Open collector Max. 50 mA (Active Low 0 V, Normally open)

Timer output

DC 5 V, 5.7k, (Low output)

Switch output

Pulse signal (Normally 5 V)

Remote control input

3.5 mm mini jack

52

English

Image 53
Contents SRT-8960 SRT-8168 SRT-8040 For customers in Canada PrecautionsMoisture Condensation Problems PrecautionsLocation Avoiding Electrical Shock and FireAccessory ContentsFeatures Front Panel Locations of Controls and IndicatorsOperation Indicators Locations of Controls and IndicatorsOperation Mode Indicator Digital DisplayWith the RS-485/232C interface board B C D Back Panel With the RS-485/232C interface boardConnections Power Cord InstallationON-SCREEN Menu Using the JOG dial and Shuttle ring for settingsMain Menu Sub-menusON-SCREEN Menu Clock setting Setting the Language and ClockLanguage Setting Factory setting Setting the Language and ClockAutomatic Daylight Saving Time Adjustment Changing the Superimpose Display Position Superimpose DisplaySelecting the Superimpose Display Video Cassette Tapes Setting the Type of Tape Used Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes Correct tape thread check functionOperation Tape ManagementIf no tape management data is present on the tape If tape management data is present on the tapeTape Management menu appears Setting the Tape Management FunctionTape Management Conflict display sample Tape Management Conflict DisplayNormal Recording Recording Speed ModeNormal Recording Before startingNormal Recording Pause/still indicator N flashesRecord Pause Recording CheckClog Detection Setting the clog detectionAction to Take when the Video Signal Deteriorates Setting the video input signal Setting the Mode at the End of the TapeSetting when not using Autorepeat recording Setting when using Autorepeat recordingAutorepeat Recording Repeat indicator lightsAutorepeat Recording ALARM/SERIES REC SET menu appears Alarm RecordingAlarm Recording Setting Alarm Recording Reset Function Alarm RecordingAlarm Recording Counter Display Connections to the Alarm in TerminalAlarm Scan Alarm SearchProgram Timer Recording Timer SET menu appears Program Timer RecordingChanging a Program Timer Recording Setting the HolidaysTo Cancel a Program Timer Recording To cancel all program timer recordingsThese portions will not be recorded Recording Using AN External Timer Input Series Recording Series Recording SetupOperation Loop recordingSingle Image Recording Single Image Recording SetupNormal Playback Special Playback Shuttle Ring Operation Special PlaybackDay/Time Search DAY/TIME SearchTape Counter Cancel the 4 digit security lock Setting the 4 digit security lockSecurity Lock Quick Method Security LockConnection Clock AdjustmentSelecting Input and Output Terminals Cassette Eject Setup Setting the Cassette Eject ModeEject output Timer OUT terminal Eject input Series in terminalSynchronization Control Operator ModeAdministrator/Installer Mode Setting the Cassette Eject ModeSynchronization Control SC will flash on the digital displaySettings when using RS-485 Setting for RS-485 or RS-232C USESetting the Address and Data Transfer Speed Power FAILURE/DEW/USED Time menu appears Tape END OUT Terminal Output Setting Timer OUT terminalOutput Terminals Tape END OUT TerminalSW OUT Terminal SW OUT Terminal Output SettingOutput Terminals ALARM@@@@@@@@@@@@Y NON@REC@@@@@@@@@@N Remote Jack Remote control settingMaintenance Maintaining and Checking The Mechanism MaintenanceMaintenance Table System Down Troubleshooting GuideAfter a Power Failure General Specifications SpecificationsConnectors VideoConnectors When the Terminal SET is set to SET2 SpecificationsOther Specifications Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR Warranty