ALARM RECORDING

Alarm Recording Reset Function

To stop the recording of an alarm, close the connection between the ALARM RESET IN terminal and the COM terminal during alarm recording.

Alarm Recording Counter Display

œDuring alarm recording, “A” will be flashing on the digital display.

œIf a superimpose display is being displayed and “ALARM COUNT” has been set to “Y” in the (DISPLAY/SW OUT SET) menu, the number of alarm recordings will flash on the monitor screen.

œThe maximum display number of alarm recordings is “999”. At the next alarm recording the counter will indicate “000”.

œWhen the (ALARM LOG) menu appears, press the MENU RESET button to reset the alarm counter to “000” (all the data of the (ALARM LOG) menu is reset).

Connections to the ALARM IN Terminal

œAlarm input signal

Connect a make-contact (no voltage) switch between the ALARM IN and COM terminals.

Checking the Alarm Recordings Time

1Press the MENU button to display the MAIN MENU.

2Turn the JOG dial to select the “9.OTHERS” line, then turn the SHUTTLE ring clockwise.

øThe (OTHERS) menu appears.

<OTHERS>

*ALARM@LOG

*POWER@FAILURE/DEW

*TERMINAL@SET@@@@SET1

3Turn the JOG dial to select the “ALARM LOG” line, then turn the SHUTTLE ring clockwise.

øThe (ALARM LOG) menu appears.

øThe number of alarm recordings, and the 10 most recent alarm recording times are displayed.

<ALARM@LOG>@@@@@@@@@010

@@@001@@@12-25@19:00

@@@002@@@11-25@23:00

@@@003@@@10-25@15:00

@@@004@@@10-25@08:00

@@@005@@@10-25@06:00

@@@006@@@10-22@19:00

@@@007@@@10-22@17:15

@@@008@@@10-22@15:45

@@@009@@@10-20@10:00

@@@010@@@10-18@12:00

œContinue turning the JOG dial to display the next (or previous) 10 alarm recording entries. When the number of alarm recording entries reaches 100, the older ones are erased as new ones are memorized.

4Press the MENU EXIT button.

NOTE:

œIf the MENU RESET button is pressed while the (ALARM LOG) menu is displayed, the displayed data is erased. “AL” will be erased from the digital display.

English

25

Image 26
Contents SRT-8960 SRT-8168 SRT-8040 Precautions For customers in CanadaLocation PrecautionsMoisture Condensation Problems Avoiding Electrical Shock and FireAccessory ContentsFeatures Locations of Controls and Indicators Front PanelOperation Mode Indicator Locations of Controls and IndicatorsOperation Indicators Digital DisplayWith the RS-485/232C interface board Back Panel With the RS-485/232C interface board B C DPower Cord Installation ConnectionsMain Menu Using the JOG dial and Shuttle ring for settingsON-SCREEN Menu Sub-menusON-SCREEN Menu Clock setting Setting the Language and ClockLanguage Setting Factory setting Setting the Language and ClockAutomatic Daylight Saving Time Adjustment Changing the Superimpose Display Position Superimpose DisplaySelecting the Superimpose Display Video Cassette Tapes Video Cassette Tapes Setting the Action to Take When a Cassette is LoadedSetting the Type of Tape Used Correct tape thread check functionIf no tape management data is present on the tape Tape ManagementOperation If tape management data is present on the tapeTape Management menu appears Setting the Tape Management FunctionTape Management Tape Management Conflict Display Conflict display sampleNormal Recording Recording Speed ModeNormal Recording Before startingRecord Pause Pause/still indicator N flashesNormal Recording Recording CheckClog Detection Setting the clog detectionAction to Take when the Video Signal Deteriorates Setting when not using Autorepeat recording Setting the Mode at the End of the TapeSetting the video input signal Setting when using Autorepeat recordingAutorepeat Recording Repeat indicator lightsAutorepeat Recording ALARM/SERIES REC SET menu appears Alarm RecordingAlarm Recording Setting Alarm Recording Counter Display Alarm RecordingAlarm Recording Reset Function Connections to the Alarm in TerminalAlarm Search Alarm ScanProgram Timer Recording Program Timer Recording Timer SET menu appearsTo Cancel a Program Timer Recording Setting the HolidaysChanging a Program Timer Recording To cancel all program timer recordingsThese portions will not be recorded Recording Using AN External Timer Input Operation Series Recording SetupSeries Recording Loop recordingSingle Image Recording Setup Single Image RecordingNormal Playback Special Playback Special Playback Shuttle Ring OperationDay/Time Search DAY/TIME SearchTape Counter Security Lock Setting the 4 digit security lockCancel the 4 digit security lock Quick Method Security LockConnection Clock AdjustmentSelecting Input and Output Terminals Eject output Timer OUT terminal Setting the Cassette Eject ModeCassette Eject Setup Eject input Series in terminalOperator Mode Synchronization ControlSynchronization Control Setting the Cassette Eject ModeAdministrator/Installer Mode SC will flash on the digital displaySettings when using RS-485 Setting for RS-485 or RS-232C USESetting the Address and Data Transfer Speed Power FAILURE/DEW/USED Time menu appears Output Terminals Timer OUT terminalTape END OUT Terminal Output Setting Tape END OUT TerminalSW OUT Terminal SW OUT Terminal Output SettingOutput Terminals ALARM@@@@@@@@@@@@Y NON@REC@@@@@@@@@@N Remote control setting Remote JackMaintenance Maintaining and Checking The Mechanism MaintenanceMaintenance Table System Down Troubleshooting GuideAfter a Power Failure Connectors SpecificationsGeneral Specifications VideoConnectors When the Terminal SET is set to SET2 SpecificationsOther Specifications Sanyo Industrial VCR Warranty Weekdays 830 AM 500 PM Pacific Time