Sharp SRT-8168, SRT-8960, SRT-8040 Alarm Recording Setting, ALARM/SERIES REC SET menu appears

Page 25

RF4QR/NA (SRT-8960 GB) Wed. May, 08/2002

ALARM RECORDING

By connecting the ALARM IN terminal to a normally open door switch, an interphone, etc., a recording can be done only when necessary.

Alarm Recording Setting

Alarm recording is performed when there is an input (trigger) at the ALARM IN terminal.

œMake all necessary connections.

œThe alarm triggers are received while in recording and stop modes.

œFollow the Before starting steps, under “NORMAL RECORDING”.

1Press the MENU button to display the MAIN MENU.

2Turn the JOG dial to select the “5.ALARM/SERIES REC SET” line, then turn the SHUTTLE ring clockwise.

øThe (ALARM/SERIES REC SET) menu appears.

<ALARM/SERIES@REC@SET>

*ALARM@SET

@@MODE@@@@@@@@@@@Y1

@@SPEED@@@@@@@@@@8H

@@DURATION@@@@@@@20S

*1@SHOT@SET

@@FIELD@@@@@@@@@@1

@@INTERVAL@@@@@@@1M

*SERIES@REC@@@@@@N

*TAPE@END@OUT@@@@8:00

3Turn the JOG dial until the “MODE” setting is highlighted, then turn the SHUTTLE ring clockwise.

4Turn the JOG dial to set the desired alarm recording mode, then turn the SHUTTLE ring clockwise.

Y1. . . . . . Alarm recording is done when there is an alarm trigger.

Y2. . . . . . Alarm recording is done only when there is an alarm trigger during duration of programmed timer recording.

Y3. . . . . . Alarm recording is done only if there is an alarm trigger and the VCR is not in programmed timer recording mode.

Y4. . . . . . Alarm recording is done only when there is an alarm trigger during programmed timer recording duration. VCR comes on records only for alarm duration. Timer recording is not possible.

N. . . . . . . Alarm recording is not performed even

if there is an alarm trigger.

5Turn the SHUTTLE ring clockwise.

6Turn the JOG dial to set the desired alarm recording speed, then turn the SHUTTLE ring clockwise.

8H (6H). . . . . . . . . . . . . 8-hour (6-hour) mode recording

24H (18H) . . . . . . . . . . 24-hour (18-hour) mode recording

40H (30H) . . . . . . . . . . 40-hour (30-hour) mode recording

NC . . . . . . . . . . . . . . . . Recording at the speed already set

œIndicated in brackets are the settings for when “TAPE” is set to “T-120” in the (GENERAL SET) menu.

7Turn the SHUTTLE ring clockwise.

8Turn the JOG dial to set the desired alarm recording duration (20S, 40S, 1M, 2M, 3M, 4M, 5M, or CC), then turn the SHUTTLE ring clockwise.

20S-5M. . Recording only for the displayed duration

CC. . . . . Recording as long as the alarm signal is being input (minimum 5 seconds)

9Press the MENU EXIT button.

NOTES:

œDuring alarm recording all buttons are disabled.

œIf “OFF” appears on the digital display, alarm recording is not possible in order to prevent the recorded tape to be recorded over. To cancel the “OFF” display, press the STOP, EJECT or PLAY button or turn the SHUTTLE ring.

œIf an alarm trigger is received while alarm recording is in progress, recording duration for the second alarm will be calculated from that point. The alarm counter will register the alarm, but it will not be found during an alarm scan and alarm search.

œIf there is a power failure during alarm recording, and the power is restored within the recording set duration, alarm recording will continue.

œIf the alarm recording duration is short, the alarms may not be found during an alarm scan or an alarm search. If the alarms are going to be reviewed using alarm scan or alarm search, then in 8-hour mode,

20-second or more recording duration should be used.

œTo do alarm recording during series recording, set “MODE” to “Y1” or “Y3”. Alarm recording will be conducted only if the VCR is recording.

œIf the recording speed mode is “000”, the recording will be in 8-hour mode irrespective of the alarm recording speed mode setting.

24

English

Image 25
Contents SRT-8960 SRT-8168 SRT-8040 For customers in Canada PrecautionsMoisture Condensation Problems PrecautionsLocation Avoiding Electrical Shock and FireFeatures ContentsAccessory Front Panel Locations of Controls and IndicatorsOperation Indicators Locations of Controls and IndicatorsOperation Mode Indicator Digital DisplayWith the RS-485/232C interface board B C D Back Panel With the RS-485/232C interface boardConnections Power Cord InstallationON-SCREEN Menu Using the JOG dial and Shuttle ring for settingsMain Menu Sub-menusON-SCREEN Menu Language Setting Setting the Language and ClockClock setting Automatic Daylight Saving Time Adjustment Setting the Language and ClockFactory setting Selecting the Superimpose Display Superimpose DisplayChanging the Superimpose Display Position Video Cassette Tapes Setting the Type of Tape Used Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes Correct tape thread check functionOperation Tape ManagementIf no tape management data is present on the tape If tape management data is present on the tapeTape Management Setting the Tape Management FunctionTape Management menu appears Conflict display sample Tape Management Conflict DisplayNormal Recording Recording Speed ModeNormal Recording Before startingNormal Recording Pause/still indicator N flashesRecord Pause Recording CheckAction to Take when the Video Signal Deteriorates Setting the clog detectionClog Detection Setting the video input signal Setting the Mode at the End of the TapeSetting when not using Autorepeat recording Setting when using Autorepeat recordingAutorepeat Recording Repeat indicator lightsAutorepeat Recording Alarm Recording Setting Alarm RecordingALARM/SERIES REC SET menu appears Alarm Recording Reset Function Alarm RecordingAlarm Recording Counter Display Connections to the Alarm in TerminalAlarm Scan Alarm SearchProgram Timer Recording Timer SET menu appears Program Timer RecordingChanging a Program Timer Recording Setting the HolidaysTo Cancel a Program Timer Recording To cancel all program timer recordingsThese portions will not be recorded Recording Using AN External Timer Input Series Recording Series Recording SetupOperation Loop recordingSingle Image Recording Single Image Recording SetupNormal Playback Special Playback Shuttle Ring Operation Special PlaybackTape Counter DAY/TIME SearchDay/Time Search Cancel the 4 digit security lock Setting the 4 digit security lockSecurity Lock Quick Method Security LockSelecting Input and Output Terminals Clock AdjustmentConnection Cassette Eject Setup Setting the Cassette Eject ModeEject output Timer OUT terminal Eject input Series in terminalSynchronization Control Operator ModeAdministrator/Installer Mode Setting the Cassette Eject ModeSynchronization Control SC will flash on the digital displaySetting the Address and Data Transfer Speed Setting for RS-485 or RS-232C USESettings when using RS-485 Power FAILURE/DEW/USED Time menu appears Tape END OUT Terminal Output Setting Timer OUT terminalOutput Terminals Tape END OUT TerminalOutput Terminals SW OUT Terminal Output SettingSW OUT Terminal ALARM@@@@@@@@@@@@Y NON@REC@@@@@@@@@@N Remote Jack Remote control settingMaintenance Maintenance Table MaintenanceMaintaining and Checking The Mechanism After a Power Failure Troubleshooting GuideSystem Down General Specifications SpecificationsConnectors VideoOther Specifications SpecificationsConnectors When the Terminal SET is set to SET2 Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR Warranty