RF4QR/NA
SPECIFICATIONS
Other Specifications
Operating temperature range | 5°C to 40°C (41°F to 104°F) |
Operating humidity range | 80% or less |
Power requirements | 120V AC,60Hz |
Power consumption | 15 W |
Dimensions (W x H x D) | 420 mm x 99.5 mm x 306 mm (16.54″ x 3.92″ x 12.05″ ) |
Weight | approximately 4.0 kg |
Connectors (When the “TERMINAL SET” is set to “SET2”)
NOTES:
œThe terminal names and signals are different from the usual setting.
œNames in brackets apply to terminals on the rear panel.
Clock set input (CONTROL IN) | No voltage, |
| Normally 5 V) |
Clock set output (CONTROL OUT) | DC 5 V, 5.7kΩ, (Low output) |
Eject input (SERIES IN) | No voltage, |
| Normally 5 V) |
Eject output (TIMER OUT) | DC 5 V, 5.7kΩ, (Low output) |
NOTE: The specifications and external appearance of this unit are subject to change without notice.