wise).
7.Replace hose and new hose clamp.
8.Perform the
TO REPLACE REGULATOR
1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.
2.Unplug unit.
3.Using an adjustable wrench remove the gauges, quick connect, and safety valve from the regulator manifold.
4.Remove the hose by removing the hose clamp. NOTE: The hose clamp is not reusable. You must purchase a new hose clamp, see the Parts List Manual or purchase a standard hose clamp at a local hardware store.
Safety Gauges
Valve
Regulator | Quick Connect |
Manifold |
|
|
5.Remove pump mounting screws securing pump (one on each side).
6.Carefully slide pump from brackets and out of the way.
7.Using an adjustable wrench remove the regulator manifold.
8.Apply pipe sealant to new regulator manifold and assemble, tighten with wrench.
9.Reapply pipe sealant to gauges, quick connect, and safety valve.
10.Reassemble all components in reverse order of removal. Make sure to orient gauges to read correctly and use wrenches to tighten all components.
Hose |
| Pump Mounting Screw |
Clamp |
|
|
|
|
|
Regulator
Manifold
Pump shown moved out of the way
Regulator
Manifold
15 - ENG | 1000003754 |