Porter-Cable 1000003754 instruction manual Risk of Electrical Shock, Electrical Grounding Failure

Page 5

 

 

 

 

 

 

HAZARD

 

 

 

 

 

 

RISK OF ELECTRICAL SHOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHAT CAN HAPPEN

HOW TO PREVENT IT

 

• Your air compressor is pow-

• Never operate the compres-

 

ered by electricity. Like any

sor outdoors when it is rain-

 

other electrically powered

ing or in wet conditions.

 

device, If it is not used properly

• Never operate compres-

 

it may cause electric shock.

sor with protective covers

 

 

 

 

 

 

 

removed or damaged.

 

• Repairs attempted by unqualified

• Any electrical wiring or repairs

 

personnel can result in serious

required on this product should be

 

injury or death by electrocution.

performed by authorized service

 

 

 

 

 

 

 

center personnel in accordance with

 

 

 

 

 

 

 

national and local electrical codes.

 

Electrical Grounding: Failure

• Make certain that the electrical

 

to provide adequate grounding

circuit to which the compressor

 

to this product could result in

is connected provides proper

 

serious injury or death from

electrical grounding, correct voltage

 

electrocution. Refer to "Grounding

and adequate fuse protection.

 

Instructions" paragraph in

 

 

the "Installation" section.

 

 

 

 

 

 

 

HAZARD

 

 

 

 

 

 

RISK FROM FLYING OBJECTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHAT CAN HAPPEN

HOW TO PREVENT IT

 

• The compressed air stream can

• Always wear certified safety equip-

 

cause soft tissue damage to

ment: ANSI Z87.1 eye protection

 

exposed skin and can propel dirt,

(CAN/CSA Z94.3) with side shields

 

chips, loose particles, and small

when using the compressor.

 

objects at high speed, resulting in

• Never point any nozzle or sprayer

 

property damage or personal injury.

toward any part of the body or

 

 

 

 

 

 

 

at other people or animals.

 

 

 

 

 

 

 

• Always turn the compressor

 

 

 

 

 

 

 

off and bleed pressure from

 

 

 

 

 

 

 

the air hose and air tank before

 

 

 

 

 

 

 

attempting maintenance, attach-

 

 

 

 

 

 

 

ing tools or accessories.

5 - ENG

1000003754

Image 5
Contents C2005 Important Safety Instructions Safety Guidelines Definitions What can Happen HOW to Prevent IT HazardRisk to Breathing Asphyxiation Risk of Bursting Attachments & accessoriesRisk from Flying Objects Risk of Electrical ShockElectrical Grounding Failure Risk from Moving Parts Risk of HOT Surfaces What can Happen HOW to Prevent ITRisk from Noise Risk of Unsafe Operation What can Happen HOW to Prevent ITRisk of Falling Accessories SpecificationsGlossary Duty CycleInstallation AssemblyHOW to SET UP Your Unit Grounding InstructionsVoltage and Circuit Protection Extension CordsDescription of Operation OperationKnow Your AIR Compressor Before Each Start-Up How to StopMotor Overload Protector not shown To Check Safety Valve MaintenanceHow to Start Customer ResponsibilitiesTo Drain Tank Service and AdjustmentsTo Replace or Clean Check Valve To Replace Regulator Storage ServiceProblem Cause Correction TroubleshootingProblem Cause Correction Problem Cause Correction Incorrect USE can Cause HAZARDS. Follow These Instructions Full ONE Year WarrantyConsignes DE Sécurité Importantes Mesures DE Sécurité DéfinitionsÉvité, pourrait causer de graves Blessures ou la mort Dommages à la propriétéCe qui peut se produire Comment l’Éviter Risque D’EXPLOSION OU D’INCENDIECE QUI Peut SE Produire Comment L’ÉVITER Risque D’ÉCLATEMENTPneus AccessoiresDirectives relatives à la mise à la Risque DE Choc ÉlectriqueMise à la terre électrique le fait de Pièces Mobiles Risque Associé AUXRisque DE Chute Modèle no C2005 LexiqueRisque Associé AU Bruit Accessoires Cycle DE ServiceAssemblage Montage DE LappareilProtection Contre LA Surtension ET Protection DU Circuit RallongesDescription DU Fonctionnement UtilisationFAMILIARISEZ-VOUS Avec Votre Compresseur Dair Arrêt de lappareil Utilisation DE LappareilMise en marche Avant chaque mise en marcheResponsabilités DU Client EntretienVérification DE LA Soupape DE Sûreté Vidange DU RéservoirRemplacement OU Nettoyage DE LA Soupape DE Retenue Pour Remplacer LE Régulateu Entretien ET Réparation RangementPièces DE Rechange Problème Cause Correction DépannageRemarque Ajustez Fusibles et remplacez-le Garantie Complète D’UN 1 AN Instrucciones Importantes DE Seguridad Definiciones DE Normas DE SeguridadMenores o moderadas Lesiones seriasPeligro ¿QUÉ Puede SUCEDER? Cómo Evitarlo Riesgo DE ExplosiónNeumáticos Elementos y accesoriosRiesgo DE Objetos Despedidos Riesgo POR Piezas Móviles Riesgo POR Ruidos ¿QUÉ Puede SUCEDER? Cómo Evitarlo Riesgo DE Caídas ¿QUÉ Puede SUCEDER? Cómo EvitarloGlosario Cuadro DE EspecificacionesCiclo DE Servicio Modelo Nº C2005Instalación EnsamblajeDesempaque Ubicación DEL Compresor DE AireProtección DEL Voltaje Y DEL Circuito Cables DE Extensión EléctricaDescripción DE Operaciones OperaciónConozca SU Compresor DE Aire Cómo detenerla Cómo Utilizar SU UnidadResponsabilidades DEL Cliente MantenimientoAntes de cada puesta en marcha Cómo poner en marchaCómo Drenar EL Tanque Cómo Verificar LA Válvula DE SeguridadPara Reemplazar O Limpiar LA Válvula Retención Servicio Y AjustesPara Reemplazar EL Regulador Servicio AlmacenajePiezas DE Repuesto Mantenimiento Y ReparacionesProblema Causa Guía DE Diagnóstico DE ProblemasAccesorios CorrecciónUsando el accesorio El motor no funciona Fusible fundido inter Garantía Completa DE UN AÑO 1000003754 Deltaportercable.com