BM 2610021316
Adjustments
Adjusting Bevel Scale pointer
Once you have adjusted the blade to the correct angle, make sure to adjust the Bevel Scale Pointer. To do so,
1.Loosen the screw which holds the pointer in place a quarter turn. (See Figure 13)
2.Align the pointer with the 0° line and retighten screw.
FIG. 13
Screw
Bevel Scale
pointer
Bevel Scale
lock Nut Bevel Stop Bolt
-2° Bevel Stop
Miter Detent System – Adjustment procedure Calibrating Miter Detent System
1.Engage the miter detent at the 0° position. Loosen the miter lock knob 1/2 turn.
2.Look for four round holes in the miter scale plate. In each hole is a screw. Use the small end of the 6/4mm hex key or a 4mm hex key to loosen all four screws 1 to 2 turns. This will loosen the miter detent plate (see Figure 14).
FIG. 14
3.Lock saw down using the head assembly lock pin (item 36 – page 8).
4.Hold one side of a 90° combination square against the fence and rotate the table (and de- tent plate) until the side of the saw blade is in full contact with the other side of the square. (See Figure 15)
FIG. 15 | Contacting |
| Blade |
Contacting
fence
Combination | Set Miter |
Square | Detent 0° |
5.Tighten all four screws – loosen and reset the miter scale pointer to the “0” position.
Miter Scale pointer Adjustment
1.Rotate table to 0° position and lock in place.
2.Raise the head assembly to the full UP position.
3.Loosen the pointer adjust screw that holds the miter scale pointer in place (see Figure 16).
pointer Adjust | FIG. 16 |
Screws |
|
Miter Scale
pointer
4.Position the pointer to align with the 0° line. Tighten the screw.
Screws | Detent plate |