Bostitch BTFP02006 instruction manual Storage and Transporting, Maintenance, Lifting

Page 14

5.Allow the compressor to cool down.

6.Wipe air compressor clean and store in a safe, non-freezing area.

STORAGE AND TRANSPORTING

Risk of property damage. In order to avoid damaging the air compressor, do not allow the unit to be tilted more than 10º when operating.

Place the air compressor in a clean, dry and well ventilated area at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air. Keep the compressor away from areas that have dirt and/or volatile fumes in the atmosphere. These impurities may clog the intake filter and valves, causing inefficient operation.

The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

Place the air compressor on a flat surface resting on the rubber feet.

Transporting

When transporting the compressor in a vehicle, trailer, etc., ensure that the tank is drained and the unit is secured and placed on a flat horizontal surface. NOTE: Use recommended tie down straps when transporting. Use care when driving so to avoid tipping the unit over in the vehicle.Damage can occur to the unit or surrounding items if unit is tipped.

Lifting

Always use two people when lifting and lift from the recommended lift points

(M & V).

 

M

 

 

 

The handle provided on a unit with

 

 

 

 

 

 

 

 

 

wheels is only intended for the purpose of pushing or

 

 

 

pulling the product.

 

 

 

MOVING

 

 

 

 

 

 

The wheels and handle do not provide

 

 

 

adequate clearance, stability, or support for pulling the

 

 

 

unit up and down stairs or steps. The unit must be lifted

v

or pushed up a ramp.

1.Grasp Handle (M) and tilt compressor so unit can be rolled on the tires.

Risk of unsafe operation. Ensure proper

footing and use caution when rolling compressor so that unit does not tip or cause loss of balance.

2.When location is reached slowly lower compressor to ground. Always store compressor in a horizontal position. NOTE: Should the unit tip over, hard starting and smoking will occur due to oil spillage.

Maintenance

The following procedures must be followed when maintenance or service is performed on the air compressor.

1.Ensure On/Off switch is in the OFF position.

2.Remove air compressor plug from outlet.

3.Drain air tank.

4.Allow air compressor to cool down before starting service.

NOTE: All compressed air systems contain maintenance parts (e.g., oil, filters, separators) that are periodically replaced. These used parts may contain substances that are regulated and must be disposed of in accordance with local, state, and federal laws and regulations.

NOTE: Take note of the positions and locations of parts during disassembly to make reassembly

14

Image 14
Contents Guide Dutilisation Manual DE Instrucciones Never place objects against or on top of compressor Risk of explosion or fire How to prevent itProperty damage What can happen Risk to Breathing Asphyxiation What can happen What can happen How to prevent itAttachments & accessories Risk of BurstingTires Risk from Flying Objects How to prevent itAlways wear certified safety equipment Risk of Unsafe Operation How to prevent it Risk of Hot surfaces How to prevent itRisk from Moving Parts How to prevent it Never stand on the compressorRisk of Falling Risk from NoiseHot Surfaces Handle Save These Instructions for Future USEAir Intake Filter Features Fig Installation AssemblyLubrication and Oil Installing HosesDisconnecting Hoses Grounding InstructionsVoltage and Circuit Protection Pre-Start Checklist FigPreparation For Use CompatibilityInitial Set-up Fig Operating ProceduresBreak-in Procedure Start-up FigTransporting MaintenanceStorage and Transporting LiftingChecking Air Filter Element Fig Maintenance ChartChecking Safety Valve Fig EasierCompressor Pump Oil Fig Valve can then be removed, cleaned and reinstalledDraining Air Tank Fig Checking oilFull One Year Warranty AccessoriesService Information RepairsGlossary Troubleshooting GuideProblem Code Weld or otherwise modify air tank or it will Solution. Do Not OvertightenCode Possible cause See Extension Cords under Installation Possible SolutionSee Motor Overload under Features La mort ou des blessures graves Définitions lignes directrices en matière de sécuritéConserver ces directives Pourrait se solder par des blessures mineures ou modéréesRisque d’Éclatement Risque Repiratoire AsphyxieComment l’Éviter Risque de choc Électrique ÉlectricitÉ Accessoires Pneus Votre compresseur d’air est alimentéRisque Provenant DES Objets Projetés EN L’AIR Risque DE Chute EmplacementInstaller un extincteur dans la zone de travail Risque associÉ au bruit Remarques À propos du bruitFiche technique Surfaces chaudesPressostat Jauge dhuile de la pompe Filtre dadmission dair L PoignéeCaractÉristiques Fig Robinet de purge Manomètre de pression réguléeRÉgulateur SystÈme de refroidissement non illustréRaccordement des tuyaux Installation des rouesAssemblage DÉconnexion des tuyauxProtection de la tension et du circuit Directives relatives à la mise à la terreRallonges La terre QListe de vérification de pré-démarrage Fig Mode d’emploiCompatibilité Procédure de rodage Procédures de fonctionnementRéglage initial Fig Démarrage FigTransport Rangement ET TransportEntretien LevageProgramme d’entretien Vérification de la soupape de sûreté FigHuile de la pompe du compresseur Fig Vérification des éléments du filtre d’air FigVidange du réservoir d’air Fig Fermer la soupape de purge dès la fin de l’opérationVidange d’huile Accesorios100/SAE40, huile non-détergente et suivez les Étapes 4 Fecha y lugar de compraCalificado. Utilice siempre piezas de repuesto idénticas Póliza de GarantíaGarantía completa de un año Esta garantía no será válida en los siguientes casosGuide de dépannage Obtenir le remplacement gratuitGlossaire Problème CodeCode Cause possible Solution ProbableCodes de dépannage ’air, ni le souder ouCaractéristiques InstallationCause possible ’enclenchementGuarde estas instrucciones Riesgo de explosión o incendioNunca coloque objetos contra o sobre el compresor Riesgo Respiratorio asfixiaRiesgo de explosión Siempre apague y desenchufe la unidad cuando no esté en usoNeumáticos Modificaciones o intento de reparación del tanque de aireElementos y accesorios Reemplácelo con un tanque de aire nuevoRiesgo DE superficies calientes Riesgo de descarga eléctricaRiesgo de objetos despedidos InstalaciónRiesgo de operación insegura Riesgo por piezas móvilesEspecificaciones Riesgo por ruidosCiclo DE Trabajo Superficies calientesTipo DE Conexión Rápida E Minutos ApagadoCaracterísticas Fig Válvula aliviadora de presión no se muestra Interruptor de Encendido/ApagadoInterruptor de presión Válvula de seguridadBomba del compresor de aire Válvula de drenajeSistema de enfriamiento no se muestra Protector DE Sobrecarga DEL Motor no se muestraInstalación EnsamblajeCables prolongadores Voltaje y protección del circuitoCompatibilidad Configuración inicial FigPreparación para el uso LugarPuesta en marcha Fig Procedimientos operativosAlmacenamiento Y Transporte Apagado FigTransporte MantenimientoConsideraciones sobre el ruido Leva ntar la unidadControlar el elemento del filtro de aire Fig Tabla de mantenimientoControlar la válvula de seguridad Fig El mantenimiento Drenar el tanque de aire FigAceite de la bomba del compresor Fig Controlar el aceiteCambio de aceite AccesoriosInformación del servicio técnico Reparaciones Guía de detección de problemas GlosarioSolución Posible Códigos de detección de problemasCódigo causa posible Ni modifique elInstalación Sión del interruptor de presión Tor de presiónColoque el interruptor Encendido De servicio de fábrica