Bosch Appliances ICP-CC404 manual Turning Outputs On/Off, Setting the Date and Time

Page 36

ICP-CC404 Installation Guide 6.0 System Functions

You can disable all zones selected to automatically isolate for STAY Mode 2 at any time.

To disable STAY Mode 2 zones:

Enter your Master Code and press [4][AWAY] [AWAY].

6.2.6Turning Outputs On/Off

If an output is programmed for remote operation, you can turn the remote output on or off using this Master Code function or remotely using the Alarm Link Software.

To use this Master Code function, you must program one or more of the outputs with these Output Event Types:

Output 1 = Output Event Type 2,8 (page 67) Output 2 = Output Event Type 2,9 (page 67) Output 3 = Output Event Type 2,10 (page 67)

To turn an output on from the remote codepad:

1.Enter your Master Code and press [5][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the number of the output (1 to 3) and press [AWAY].

Three beeps sound and the output turns on.

3.Repeat Step 2 to turn on another output.

4.Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY indicators turn off.

Example

If Output 2 is programmed as 291000 in Locations 374 to 379, the Master Code holder can turn on this output by entering:

[2 5 8 0 5][AWAY][2][AWAY][AWAY]

To turn off an output from the remote codepad:

1.Enter your Master Code and press [5][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the number of the output (1 to 3) and press [STAY].

Two beeps sound and the output turns off.

3.Repeat Step 2 to turn off another output.

4.Press [AWAY] button to exit from this function. Two beeps sound and the STAY and AWAY indicators turn off.

Example

If Output 2 is programmed as 291000 in Locations 374 to 379, the Master Code holder can turn off this output by entering:

[2 5 8 0 5][AWAY][2][STAY][AWAY]

6.2.7Setting the Date and Time

Use this function to change the date and time or if power was removed from the system.

If the date and time are not set, the date and time fault is shown only when the Auto Arming Time is programmed in Locations 414 to 417 (refer to Section

17.12Auto Arming Time on page 72), or when you enter Fault Analysis Mode by holding down [5].

To set the new date and time:

1.Enter your Master Code and press [6][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the day, month, year, hour, and minute in DD, MM, YY, HH, MM format (where DD is the day of the month, MM is the month of the year, YY is the year, HH is the hour of the day, and MM minute of the day) and press [AWAY].

Use 24:00 hour format when programming the hour of the day.

Two beeps sound and the STAY and AWAY indicators turn off. If a long beep sounds, there was an error when you entered the date and time.

Example

To set the date and time for the 1st January 20064 at 10:30 PM, enter:

[2 5 8 0 6][AWAY][0 1 0 1 0 6 2 2 3 0][AWAY]

6.2.8Walk Test Mode

Walk Test Mode allows you to test detection devices to ensure they are functioning correctly. Before activating Walk Test Mode, isolate any zones that are not required for testing. Refer to Section 4.11 Isolating Zones on page 21 for more information.

To enter Walk Test Mode:

1.Enter your Master Code and press [7][AWAY]. Three beeps sound and the STAY and AWAY indicators flash. The codepad beeps once per sec when Walk Test Mode is active.

2.Unseal and seal the zones to be tested.

The codepad sounds one long beep and the horn speaker sounds one short beep each time a zone is sealed or unsealed.

3.Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY indicators turn off. The system returns to the disarmed state.

6.2.9Event Memory Recall Mode

Event Memory Recall Mode allows you to play back the last forty system events. Event Memory Recall Mode shows all alarms and each arming or disarming of the system and helps with troubleshooting system faults. The events are shown using the codepad indicators.

36

Bosch Security Systems, Inc. 12/08 F01U089401-02

Image 36
Contents Installation Guide ICP-CC404ICP-CC404 Installation Guide Copyright Notice Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Features ICP-CC404 Installation Guide 1.0 IntroductionIntroduction Quick StartSetting the Date and Time Zone DefaultsExample Zone TypesICP-CC404 Installation Guide 2.0 Programming Codepad IndicatorsProgramming Programming with the Remote CodepadInstaller’s Programming Commands Installer’s Programming Mode CommandsProgramming with the Programming Key Programming Option BitsCommand 958 Enable/Disable Zone Status Mode Command 959 Test the Programming KeyCommand 960 Exit from the Installers Programming Mode Command 963 Copy the Programming Key to the Control PanelCommand 964 Erase the Programming Key Command 965 Set Up Domestic Dialing FormatCommand 966 Enable or Disable Auto Step Mode Command 965 Defaults Example Auto Step Mode EnabledExample Auto Step Mode Disabled ProgrammingDisable Factory Defaults Using this feature is not recommendedCodepad Indicators ICP-CC404 Installation Guide 3.0 Codepad IndicatorsICP-CP508W Eight Zone LED Codepad Audible Indicators ICP-CP508LW Eight Zone LCD CodepadSystem Disarmed Disarming the System from Away Mode Arming the System in Away ModeICP-CC404 Installation Guide 4.0 System Operations System OperationsArming the System in Stay Mode Disarming the System from Stay ModeEntry Guard Timer for Stay Mode Arming the System in Stay Mode Codepad Duress Alarm Codepad Panic AlarmCodepad Fire Alarm Codepad Medical AlarmFault Analysis Mode Fault DescriptionsFault Indicators Low BatteryTelephone Line Fault Date and TimeSensor Watch Horn Speaker MonitorRemote Radio Transmitter Operations Indications from Remote Radio Transmitter OperationsRemote Radio User Code Priority Levels Changing or Deleting Remote Radio User CodesCodepad Indicators for Remote Radio User Numbers Arming in Away ModeDisarming from Away Mode Arming in Stay ModeDisarming from Stay Mode Panic AlarmFour-Channel Remote Radio Hand- Held Transmitter Operations Installer Code Functions ICP-CC404 Installation Guide 6.0 System FunctionsSystem Functions Codepad Indicators When Changing Phone Numbers Changing Domestic Phone NumbersDomestic Dialing Digits Change Telco Arming or Disarming SequenceCodepad Indicators When Changing Telco Arming or Disarming Dialing DigitsTelco Arming or Disarming SequenceSetting Stay Mode 2 Zones Satellite Siren Service ModeTurning Telephone Monitor Mode On and Off Telephone Monitor Mode IndicationsEvent Memory Recall Mode Master Code FunctionsRemote Radio Numbers Displayed by the Codepad Indicators Master Code FunctionsChanging and Deleting User Codes Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions ICP-CC404 Installation Guide 7.0 Remote Arming by Telephone Remote Arming by TelephoneAlarm Link Software ICP-CC404 Installation Guide 8.0 Alarm Link SoftwareRemote Connect Alarm Link Options ICP-CC404 Installation Guide 9.0 Domestic DialingDomestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting ICP-CC404 Installation Guide 10.0 Dialer Reporting Formats Dialer Reporting FormatsTransmission Formats Contact ID FormatPoint ID Codes 10.1.3 4 + 2 Express Reporting FormatExample Reporting in 4 + 2 Express Format + 2 Express Reporting Format+2 Express Transmission Code Descriptions Basic Pager Reporting FormatBasic Pager Display Information Subscriber ID NumberZone Status Zone Status Display DescriptionsICP-CC404 Installation Guide 11.0 Dialer Information Dialer InformationPrimary Telephone Number for Receiver 1 and Receiver System StatusSecondary Telephone Number for Receiver 1 and Receiver Handshake Tone for Receiver 1 and ReceiverTransmission Format for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverDialing Format Telco Arming SequenceTelco Disarming Sequence Telephone Line Fault Options Call Back Telephone NumberRing Count Answering Machine BypassICP-CC404 Installation Guide 12.0 Dialer Options Dialer OptionsDialer Options Access Code Installer CodeICP-CC404 Installation Guide 13.0 Access Code User CodesUser Code Priority Day Alarm Information ICP-CC404 Installation Guide 14.0 Zone InformationZone Information EOL Resistor ValueZone Programming Zone Operating InformationZone Options Zone Reporting InformationZone Programming Defaults Delay-1 ZoneDelay-2 Zone Zone Types Instant ZoneKeyswitch Zone Hour Holdup ZoneHour Tamper Zone 12 24-Hour Burglary ZoneDelay Alarm Reporting Silent AlarmKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Disarm from Away Mode, Stay Mode 1, or Stay Mode Latching Arm and Disarm in Stay ModeLatching Arm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Siren Swinger Shutdown Count for DialerZone Status Alarm Restore Code System Reporting InformationZone Status Bypass Reports Zone Status Trouble ReportsZone Status Reporting Options Open/Close ReportsOpen/Close Reporting Options Codepad Duress ReportSystem Status AUX Power Supply Fail Report System Status AUX Power Supply Fail Restore ReportSystem Status AC Fail Restore Report System Status Low Battery ReportSystem Status Low Battery Restore Report System Status Access DeniedSystem Status Reporting Options Test Reporting TimeICP-CC404 Installation Guide 16.0 Programmable Outputs Programmable OutputsTest Reporting Dialer Options Redirecting Outputs to the Codepad BuzzerOutput Event Types Day Alarm Enabled AUX Power Supply FailSensor Watch Alarm Codepad Medical AlarmCodepad Tamper Access Denied Alarm When in Stay ModeAlarm When in Away Mode Mimic System FaultOutput Polarity Normally Open, One-Shot Low with Reset Normally Open, One-Shot Low with AlarmNormally Low, One-Shot Open with Reset Event Type PolaritiesSystem Event Timers Entry Guard Timer for Stay Mode Delay Alarm Reporting TimeExit Time Sensor Watch TimeAuto Arming Pre-Alert Timer Auto Arming TimeAuto Disarming Time Kiss-Off Wait TimeSystem and Consumer Options System OptionsSilent Access Denied Code Retries Sequential Handover DelayPanel Powers Up Disarmed Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.9 PS101 Power Supply Module 19.7 CP5 Eight Zone LCD Codepad CP508LW19.8 CP105A Night Arm Station 19.10 TF008 Plug Pack TF008Terminals and Descriptions Terminal DescriptionsGlossary Of Terms Domestic alarm reports That an alarm was sent outStay Mode This mode. Only the installer can program these zonesDiagrams ICP-CC404 Wiring DiagramICP-CC404 Component Overlay 4 not connected Specifications Warranty StatementAdvice to Users ICP-CC404 Installation Guide 21.0 SpecificationsICP-CC404 Installation Guide 22.0 Programming Sheets Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones 22.0 Programming SheetsICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets Country Codes PRCICP-CC404 Installation Guide Contents ICP-CC404 Installation Guide Index IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02