Bosch Appliances ICP-CC404 Setting Up and Programming Domestic Reporting, Domestic Dialing Digits

Page 41

ICP-CC404 Installation Guide 9.0 Domestic Dialing

If a busy tone is not detected, the control panel assumes that the telephone was answered and sends its transmission. The transmission sequence consists of an identification beep, followed by a siren tone and a long pause. The transmission sequence is repeated until the control panel receives an acknowledgment tone during the pause. The control panel automatically hangs up after 2 min. If more than one control panel sends reports to the same telephone number, the identification beep allows the customer to identify the control panel that called. The identification beep is programmed in Location 039 of the Subscriber ID Number for Receiver 1 or Location 079 of the Subscriber ID Number for Receiver 2.

When set up for Domestic Dialing Format, the control panel attempts up to six calls per alarm event. This count includes any unsuccessful calls. The counter is reset if the zone is reactivated and the control panel attempts six additional calls. The control panel stops dialing after six attempts or three successful calls. The control panel also stops dialing if a valid User Code is entered at the remote codepad.

If both Receiver 1 and Receiver 2 are programmed for domestic dialing, the maximum number of calls per alarm event is twelve.

To acknowledge domestic dialing:

If the received call is not acknowledged during any of the transmission pauses by pressing the [*] button on

atouch-tone telephone or by using the CC911 Phone Controller, the control panel continues to send its transmission for 2 min. It then hangs up and dials the next telephone number. If the call is successfully acknowledged, the control panel hangs up and makes no more calls for that event.

9.2Setting Up and Programming Domestic Reporting

Programming the control panel for domestic reporting is extremely simple when using the Installer’s Programming Command 965. Refer to Section 2.4.8 Command 965 – Set Up Domestic Dialing Format on page 13 for more information.

To set up the control panel for domestic dialing:

1.Enter the Installer Code and press [AWAY] to enter Installer’s Programming Mode.

Two beeps sound and the STAY and AWAY indicators flash.

2.Enter [9 6 5] and press [AWAY].

Two beeps sound. The control panel is now set up for Domestic Dialing Format.

3.Enter [9 6 0] and press [AWAY] to exit from the Installer’s Programming Mode.

Two beeps sound and the STAY and AWAY indicators turn off. The system returns to the disarmed state.

4.To program your telephone numbers, enter the Installer Code and press [2][AWAY].

Three beeps sound and the STAY and AWAY indicators flash.

If there are telephone numbers already programmed, they appear one digit at a time using the codepad indicators.

If there are no programmed telephone numbers, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the last phone number lights.

5.Enter the digits for telephone number 1, one digit at a time (refer to Table 31).

As you enter each digit, the corresponding codepad indicator lights.

Table 31: Domestic Dialing Digits

 

 

 

 

Digit

Number to

Digit

Number to

Required

Program

Required

Program

 

 

 

 

0

0

8

8

1

1

9

9

2

2

10

refer to 0

3

3

*

* 1

4

4

#

* 2

5

5

4 sec pause

* 3

 

 

 

 

6

6

break

* 4

7

7

15

* 5

6.After you enter all the digits of the first telephone number, press [STAY][4] to insert a break between the first telephone number and the second telephone number.

7.Repeat Step 6 for each additional phone number.

8.After the last digit of the last telephone number, press [AWAY] to exit from this mode.

Example

To program two separate telephone numbers (9672

1777 and 9672 1233), enter the following sequence:

[1 2 3 4 2][AWAY][9 6 7 2 1 7 7 7][STAY]

[4 9 6 7 2 1 2 3 3][[AWAY]

You can cancel domestic dialing at any time (for example, you are moving house and do not want the system to continue calling your work place or mobile phone).

To disable domestic dialing:

Enter the Installer Code and press [2][AWAY][STAY][4][AWAY].

Bosch Security Systems, Inc. 12/08 F01U089401-02

41

Image 41
Contents ICP-CC404 Installation GuideCopyright Notice ICP-CC404 Installation Guide Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables ICP-CC404 Installation Guide 1.0 Introduction FeaturesIntroduction Quick StartZone Defaults Setting the Date and TimeExample Zone TypesCodepad Indicators ICP-CC404 Installation Guide 2.0 ProgrammingProgramming Programming with the Remote CodepadInstaller’s Programming Mode Commands Installer’s Programming CommandsProgramming with the Programming Key Programming Option BitsCommand 959 Test the Programming Key Command 958 Enable/Disable Zone Status ModeCommand 963 Copy the Programming Key to the Control Panel Command 960 Exit from the Installers Programming ModeCommand 966 Enable or Disable Auto Step Mode Command 964 Erase the Programming KeyCommand 965 Set Up Domestic Dialing Format Example Auto Step Mode Enabled Command 965 DefaultsExample Auto Step Mode Disabled ProgrammingUsing this feature is not recommended Disable Factory DefaultsICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC404 Installation Guide 3.0 Codepad Indicators System Disarmed Audible IndicatorsICP-CP508LW Eight Zone LCD Codepad Arming the System in Away Mode Disarming the System from Away ModeICP-CC404 Installation Guide 4.0 System Operations System OperationsEntry Guard Timer for Stay Mode Arming the System in Stay ModeDisarming the System from Stay Mode Arming the System in Stay Mode Codepad Panic Alarm Codepad Duress AlarmCodepad Fire Alarm Codepad Medical AlarmFault Descriptions Fault Analysis ModeFault Indicators Low BatteryDate and Time Telephone Line FaultSensor Watch Horn Speaker MonitorIndications from Remote Radio Transmitter Operations Remote Radio Transmitter OperationsRemote Radio User Code Priority Levels Changing or Deleting Remote Radio User CodesArming in Away Mode Codepad Indicators for Remote Radio User NumbersDisarming from Away Mode Arming in Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations Disarming from Stay ModePanic Alarm System Functions Installer Code FunctionsICP-CC404 Installation Guide 6.0 System Functions Changing Domestic Phone Numbers Codepad Indicators When Changing Phone NumbersDomestic Dialing Digits Change Telco Arming or Disarming SequenceTelco Arming or Disarming Dialing Digits Codepad Indicators When ChangingTelco Arming or Disarming SequenceSatellite Siren Service Mode Setting Stay Mode 2 ZonesTelephone Monitor Mode Indications Turning Telephone Monitor Mode On and OffEvent Memory Recall Mode Master Code FunctionsMaster Code Functions Remote Radio Numbers Displayed by the Codepad IndicatorsChanging and Deleting User Codes Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions Remote Arming by Telephone ICP-CC404 Installation Guide 7.0 Remote Arming by TelephoneRemote Connect Alarm Link SoftwareICP-CC404 Installation Guide 8.0 Alarm Link Software ICP-CC404 Installation Guide 9.0 Domestic Dialing Alarm Link OptionsDomestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting Dialer Reporting Formats ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsTransmission Formats Contact ID Format10.1.3 4 + 2 Express Reporting Format Point ID CodesExample Reporting in 4 + 2 Express Format + 2 Express Reporting FormatBasic Pager Reporting Format +2 Express Transmission Code DescriptionsSubscriber ID Number Basic Pager Display InformationZone Status Zone Status Display DescriptionsDialer Information ICP-CC404 Installation Guide 11.0 Dialer InformationPrimary Telephone Number for Receiver 1 and Receiver System StatusHandshake Tone for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverTransmission Format for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverTelco Disarming Sequence Dialing FormatTelco Arming Sequence Call Back Telephone Number Telephone Line Fault OptionsRing Count Answering Machine BypassDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options Installer Code Access CodeICP-CC404 Installation Guide 13.0 Access Code User CodesUser Code Priority ICP-CC404 Installation Guide 14.0 Zone Information Day Alarm InformationZone Information EOL Resistor ValueZone Operating Information Zone ProgrammingZone Options Zone Reporting InformationDelay-1 Zone Zone Programming DefaultsDelay-2 Zone Zone Types Instant ZoneHour Holdup Zone Keyswitch ZoneHour Tamper Zone 12 24-Hour Burglary ZoneSilent Alarm Delay Alarm ReportingKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Arm and Disarm in Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Dialer Swinger Shutdown Count for SirenSystem Reporting Information Zone Status Alarm Restore CodeZone Status Bypass Reports Zone Status Trouble ReportsOpen/Close Reports Zone Status Reporting OptionsOpen/Close Reporting Options Codepad Duress ReportSystem Status AUX Power Supply Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AC Fail Restore Report System Status Low Battery ReportSystem Status Access Denied System Status Low Battery Restore ReportSystem Status Reporting Options Test Reporting TimeProgrammable Outputs ICP-CC404 Installation Guide 16.0 Programmable OutputsTest Reporting Dialer Options Redirecting Outputs to the Codepad BuzzerOutput Event Types AUX Power Supply Fail Day Alarm EnabledSensor Watch Alarm Codepad Medical AlarmAlarm When in Stay Mode Codepad Tamper Access DeniedAlarm When in Away Mode Mimic System FaultOutput Polarity Normally Open, One-Shot Low with Alarm Normally Open, One-Shot Low with ResetNormally Low, One-Shot Open with Reset Event Type PolaritiesSystem Event Timers Delay Alarm Reporting Time Entry Guard Timer for Stay ModeExit Time Sensor Watch TimeAuto Arming Time Auto Arming Pre-Alert TimerAuto Disarming Time Kiss-Off Wait TimeSystem Options System and Consumer OptionsSequential Handover Delay Silent Access Denied Code RetriesPanel Powers Up Disarmed Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.7 CP5 Eight Zone LCD Codepad CP508LW 19.9 PS101 Power Supply Module19.8 CP105A Night Arm Station 19.10 TF008 Plug Pack TF008Terminal Descriptions Terminals and DescriptionsGlossary Of Terms That an alarm was sent out Domestic alarm reportsStay Mode This mode. Only the installer can program these zonesICP-CC404 Wiring Diagram DiagramsICP-CC404 Component Overlay 4 not connected Warranty Statement SpecificationsAdvice to Users ICP-CC404 Installation Guide 21.0 SpecificationsProgramming Sheets ICP-CC404 Installation Guide 22.0 Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones Programming Sheets 22.0ICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets PRC Country CodesICP-CC404 Installation Guide Contents Index ICP-CC404 Installation Guide IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02