Bosch Appliances ICP-CC404 manual System Operations, Disarming the System from Away Mode

Page 18

ICP-CC404 Installation Guide 4.0 System Operations

Zone Isolating Mode

 

This indicator (the person) flashes once

 

every 3 sec when you attempt to isolate

 

zones or program zones to automatically

Flashing

isolate for STAY Mode 2.

 

For more information, refer to:

Section 4.11 on page 21 to manually isolate zones.

Section 6.1.4 on page 30 to use the Installer Code to set zones to automatically isolated in STAY Mode 2.

Section 6.2.5 on page 35 to use the Master Code to set zones to automatically isolate in STAY Mode 2.

Fault Indicator

The fault indicator lights when the system detects a system fault (refer to Table 12 on page 17). Refer to Section

4.12Fault Analysis Mode on page 22 for more information on system faults.

Each time a new system fault is detected (the fault indicator flashes), the codepad beeps once per minute. Press [AWAY] to stop the beeping and acknowledge the fault.

Programming Mode

These two indicators flash when you enter Installer’s Programming Mode or use any Master Code function.

Flashing

OFF Indicator/Zone Sealed

The OFF indicator lights when the system is disarmed and flashes when a zone becomes unsealed when disarmed. The indicator stops flashing when all zones are sealed.

ON Indicator/Zone in Alarm

The ON indicator lights when the system is armed and flashes when an alarm occurs. The indicator resets after a valid User Code is entered.

Audible Indicators

The codepad provides a number of audible indications. Refer to Table 13 on page 17.

4.0 System Operations

There are two different methods to arm the system in AWAY Mode. You can always use the first method. You can use the other method only if Option 2 is enabled in Location 429 (refer to Section 18.6 Consumer Options 2 on page 75).

If you must isolate a zone(s) before arming the system in AWAY Mode, refer to Section 4.11 Isolating Zones on page 21.

Single button arming in AWAY Mode reports as User Code number 16.

To arm the system in AWAY Mode (method one): Enter your code and press [AWAY].

Two beeps sound, the AWAY indicator lights, and Exit Time starts.

To arm the system in AWAY Mode (method two):

Select Option 2 in Location 429 to enable single button arming in AWAY Mode (refer to Section 18.6 Consumer Options 2 on page 75).

1.Press and hold [AWAY].

2.When two beeps sound, release the button.

The AWAY indicator lights and Exit Time starts.

If a zone is not sealed at the end of Exit Time, the zone is automatically isolated and its indicator lights on the remote codepad. The zone becomes an active part of the system again after it is resealed. For example, if a window is open when Exit Time expires, the window is not an active part of the system until it is closed. Opening the window after Exit Time expires causes an alarm.

Forced Arming

Arming the system when a zone is not sealed is known as forced arming. Refer to Section 14.3.6 Zone Options 2 on page 58 to enable forced arming for each zone.

If the AWAY indicator does not light and a long beep sounds when you attempt to arm the system in AWAY Mode, forced arming is not permitted. If this is the case, you seal all zones or manually isolate them before you can arm the system.

4.2Disarming the System from AWAY Mode

This section explains the general operations of the system: arming and disarming the system in the three modes, isolating zones, initiating codepad alarms, and determining a fault.

4.1Arming the System in AWAY Mode

Arming the system in AWAY Mode is normally performed when you leave the premises and want all zones ready to detect an intrusion.

When you enter the premises after the system is armed in AWAY Mode, you must disarm the system from AWAY Mode to disable detection devices that activate the siren, strobe, and bell outputs.

If there was an alarm before disarming the system from AWAY Mode, a zone indicator flashes to indicate a previous alarm in that zone.

To disarm the system from AWAY Mode:

Enter your code and press [AWAY].

18

Bosch Security Systems, Inc. 12/08 F01U089401-02

Image 18
Contents Installation Guide ICP-CC404ICP-CC404 Installation Guide Copyright Notice Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Introduction FeaturesICP-CC404 Installation Guide 1.0 Introduction Quick StartExample Setting the Date and TimeZone Defaults Zone TypesProgramming ICP-CC404 Installation Guide 2.0 ProgrammingCodepad Indicators Programming with the Remote CodepadProgramming with the Programming Key Installer’s Programming CommandsInstaller’s Programming Mode Commands Programming Option BitsCommand 958 Enable/Disable Zone Status Mode Command 959 Test the Programming KeyCommand 960 Exit from the Installers Programming Mode Command 963 Copy the Programming Key to the Control PanelCommand 964 Erase the Programming Key Command 965 Set Up Domestic Dialing FormatCommand 966 Enable or Disable Auto Step Mode Example Auto Step Mode Disabled Command 965 DefaultsExample Auto Step Mode Enabled ProgrammingDisable Factory Defaults Using this feature is not recommendedCodepad Indicators ICP-CC404 Installation Guide 3.0 Codepad IndicatorsICP-CP508W Eight Zone LED Codepad Audible Indicators ICP-CP508LW Eight Zone LCD CodepadSystem Disarmed ICP-CC404 Installation Guide 4.0 System Operations Disarming the System from Away ModeArming the System in Away Mode System OperationsArming the System in Stay Mode Disarming the System from Stay ModeEntry Guard Timer for Stay Mode Arming the System in Stay Mode Codepad Fire Alarm Codepad Duress AlarmCodepad Panic Alarm Codepad Medical AlarmFault Indicators Fault Analysis ModeFault Descriptions Low BatterySensor Watch Telephone Line FaultDate and Time Horn Speaker MonitorRemote Radio User Code Priority Levels Remote Radio Transmitter OperationsIndications from Remote Radio Transmitter Operations Changing or Deleting Remote Radio User CodesDisarming from Away Mode Codepad Indicators for Remote Radio User NumbersArming in Away Mode Arming in Stay ModeDisarming from Stay Mode Panic AlarmFour-Channel Remote Radio Hand- Held Transmitter Operations Installer Code Functions ICP-CC404 Installation Guide 6.0 System FunctionsSystem Functions Domestic Dialing Digits Codepad Indicators When Changing Phone NumbersChanging Domestic Phone Numbers Change Telco Arming or Disarming SequenceTelco Arming or Disarming Codepad Indicators When ChangingTelco Arming or Disarming Dialing Digits SequenceSetting Stay Mode 2 Zones Satellite Siren Service ModeEvent Memory Recall Mode Turning Telephone Monitor Mode On and OffTelephone Monitor Mode Indications Master Code FunctionsChanging and Deleting User Codes Remote Radio Numbers Displayed by the Codepad IndicatorsMaster Code Functions Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions ICP-CC404 Installation Guide 7.0 Remote Arming by Telephone Remote Arming by TelephoneAlarm Link Software ICP-CC404 Installation Guide 8.0 Alarm Link SoftwareRemote Connect Domestic Dialing Alarm Link OptionsICP-CC404 Installation Guide 9.0 Domestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting Transmission Formats ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsDialer Reporting Formats Contact ID FormatExample Reporting in 4 + 2 Express Format Point ID Codes10.1.3 4 + 2 Express Reporting Format + 2 Express Reporting Format+2 Express Transmission Code Descriptions Basic Pager Reporting FormatZone Status Basic Pager Display InformationSubscriber ID Number Zone Status Display DescriptionsPrimary Telephone Number for Receiver 1 and Receiver ICP-CC404 Installation Guide 11.0 Dialer InformationDialer Information System StatusTransmission Format for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverDialing Format Telco Arming SequenceTelco Disarming Sequence Ring Count Telephone Line Fault OptionsCall Back Telephone Number Answering Machine BypassICP-CC404 Installation Guide 12.0 Dialer Options Dialer OptionsDialer Options ICP-CC404 Installation Guide 13.0 Access Code Access CodeInstaller Code User CodesUser Code Priority Zone Information Day Alarm InformationICP-CC404 Installation Guide 14.0 Zone Information EOL Resistor ValueZone Options Zone ProgrammingZone Operating Information Zone Reporting InformationDelay-2 Zone Zone Programming DefaultsDelay-1 Zone Zone Types Instant ZoneHour Tamper Zone Keyswitch ZoneHour Holdup Zone 12 24-Hour Burglary ZoneKeyswitch Zone Options Delay Alarm ReportingSilent Alarm Latching Arm and Disarm in Away ModeLatching Arm in Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm and Disarm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Siren Swinger Shutdown Count for DialerZone Status Bypass Reports Zone Status Alarm Restore CodeSystem Reporting Information Zone Status Trouble ReportsOpen/Close Reporting Options Zone Status Reporting OptionsOpen/Close Reports Codepad Duress ReportSystem Status AC Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AUX Power Supply Fail Restore Report System Status Low Battery ReportSystem Status Reporting Options System Status Low Battery Restore ReportSystem Status Access Denied Test Reporting TimeTest Reporting Dialer Options ICP-CC404 Installation Guide 16.0 Programmable OutputsProgrammable Outputs Redirecting Outputs to the Codepad BuzzerOutput Event Types Sensor Watch Alarm Day Alarm EnabledAUX Power Supply Fail Codepad Medical AlarmAlarm When in Away Mode Codepad Tamper Access DeniedAlarm When in Stay Mode Mimic System FaultOutput Polarity Normally Low, One-Shot Open with Reset Normally Open, One-Shot Low with ResetNormally Open, One-Shot Low with Alarm Event Type PolaritiesSystem Event Timers Exit Time Entry Guard Timer for Stay ModeDelay Alarm Reporting Time Sensor Watch TimeAuto Disarming Time Auto Arming Pre-Alert TimerAuto Arming Time Kiss-Off Wait TimeSystem and Consumer Options System OptionsPanel Powers Up Disarmed Silent Access Denied Code RetriesSequential Handover Delay Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.8 CP105A Night Arm Station 19.9 PS101 Power Supply Module19.7 CP5 Eight Zone LCD Codepad CP508LW 19.10 TF008 Plug Pack TF008Terminals and Descriptions Terminal DescriptionsGlossary Of Terms Stay Mode Domestic alarm reportsThat an alarm was sent out This mode. Only the installer can program these zonesDiagrams ICP-CC404 Wiring DiagramICP-CC404 Component Overlay 4 not connected Advice to Users SpecificationsWarranty Statement ICP-CC404 Installation Guide 21.0 SpecificationsICP-CC404 Installation Guide 22.0 Programming Sheets Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones 22.0 Programming SheetsICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets Country Codes PRCICP-CC404 Installation Guide Contents ICP-CC404 Installation Guide Index IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02