Bosch Appliances ICP-CC404 manual Remote Arming by Telephone

Page 38

ICP-CC404 Installation Guide 7.0 Remote Arming by Telephone

6.3.7Turning Day Alarm On and Off

Pressing and holding [4] turns Day Alarm on or off. If you want the STAY indicator to indicate the status of Day Alarm operation (enabled or disabled), select Option 8 in Location 428 (refer to Section 18.5 Consumer Options 1 on page 75). When this option is selected, the STAY indicator flashes once every 3 sec when Day Alarm is active.

To turn Day Alarm on:

Press and hold [4] until three beeps sound.

To turn Day Alarm off:

Press and hold [4] until two beeps sound.

6.3.8Fault Analysis Mode

There are a number of system faults that can be detected by the control panel. When any of these faults are present, the FAULT indicator flashes and the codepad beeps once per minute. Refer to Section

4.12Fault Analysis Mode on page 22 for more information on each fault type.

To determine the type of fault:

Press and hold [5] until two beeps sound.

The STAY, AWAY, and FAULT indicators flash. One or more zone indicators (1 to 8) light to indicate the type of fault that occurred. Refer to Table 14 on page 22.

To Exit from Fault Analysis Mode:

Press [AWAY].

The STAY and AWAY indicators turn off and the system returns to the disarmed state.

6.3.9Initiate a Modem Call

Pressing and holding [6] until two beeps sound forces the control panel to dial the callback telephone number programmed in Locations 159 to 174 (refer to Section 11.9 Call Back Telephone Number on page 49) in an attempt to connect to the installer’s remote computer.

The remote computer must be running the CC816 Alarm Link Software and must be set to Waiting for an Incoming Call. If no callback telephone number is programmed, pressing and holding [6] has no effect.

6.3.10 Reset Latching Outputs

Pressing and holding [7] until two beeps sound resets any output that is programmed to remain on after it is activated.

The output must be programmed with a latching polarity. Refer to Section 16.3 Output Polarity on page 68 for more information.

6.3.11 Codepad Buzzer Tone Change

Pressing and holding [8] down continuously changes the tone of the buzzer in the remote codepad. There are fifty different tones from 1500 Hz to 5000 Hz. In an installation with multiple codepads, you can set a different tone for each codepad.

To change the buzzer tone:

1.Press and hold [8] continuously.

The tone of the buzzer increases in pitch.

2.Release [8] button when you hear the desired tone.

Every time power is removed from the system, you must reset each codepad to its individual tone using this function.

6.3.12 Send Test Report

Pressing and holding [9] until two beeps sound sends a Test Report (Contact ID Event Code 602) to test the dialing and reporting capabilities of the system without activating the sirens.

7.0Remote Arming by

Telephone

You can arm your system from any remote location by telephone. For security reasons, you cannot disarm the system using this method. A touch-tone telephone is required to use this feature.

To remotely arm your system by telephone:

1.Call the telephone number to which your control panel is connected.

When the control panel answers the incoming call, a short jingle sounds.

If you hear a number of unusual tones when the control panel answers the incoming call, the system is programmed for remote programming functions. Wait for a pause in the tones and follow Step 2 to arm the system remotely.

2.Hold the phone controller to the mouthpiece of the telephone and press and hold the button on the side of the unit for 3 sec.

You can also press and hold [*] on the touch-tone telephone for 3 sec to arm the system.

Two beeps sound to indicate that the system is armed in AWAY Mode.

3.Hang up the telephone. The system remains armed.

38

Bosch Security Systems, Inc. 12/08 F01U089401-02

Image 38
Contents Installation Guide ICP-CC404ICP-CC404 Installation Guide Copyright Notice Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Introduction FeaturesICP-CC404 Installation Guide 1.0 Introduction Quick StartExample Setting the Date and TimeZone Defaults Zone TypesProgramming ICP-CC404 Installation Guide 2.0 ProgrammingCodepad Indicators Programming with the Remote CodepadProgramming with the Programming Key Installer’s Programming CommandsInstaller’s Programming Mode Commands Programming Option BitsCommand 958 Enable/Disable Zone Status Mode Command 959 Test the Programming KeyCommand 960 Exit from the Installers Programming Mode Command 963 Copy the Programming Key to the Control PanelCommand 966 Enable or Disable Auto Step Mode Command 964 Erase the Programming KeyCommand 965 Set Up Domestic Dialing Format Example Auto Step Mode Disabled Command 965 DefaultsExample Auto Step Mode Enabled ProgrammingDisable Factory Defaults Using this feature is not recommendedICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC404 Installation Guide 3.0 Codepad Indicators System Disarmed Audible IndicatorsICP-CP508LW Eight Zone LCD Codepad ICP-CC404 Installation Guide 4.0 System Operations Disarming the System from Away ModeArming the System in Away Mode System OperationsEntry Guard Timer for Stay Mode Arming the System in Stay ModeDisarming the System from Stay Mode Arming the System in Stay Mode Codepad Fire Alarm Codepad Duress AlarmCodepad Panic Alarm Codepad Medical AlarmFault Indicators Fault Analysis ModeFault Descriptions Low BatterySensor Watch Telephone Line FaultDate and Time Horn Speaker MonitorRemote Radio User Code Priority Levels Remote Radio Transmitter OperationsIndications from Remote Radio Transmitter Operations Changing or Deleting Remote Radio User CodesDisarming from Away Mode Codepad Indicators for Remote Radio User NumbersArming in Away Mode Arming in Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations Disarming from Stay ModePanic Alarm System Functions Installer Code FunctionsICP-CC404 Installation Guide 6.0 System Functions Domestic Dialing Digits Codepad Indicators When Changing Phone NumbersChanging Domestic Phone Numbers Change Telco Arming or Disarming SequenceTelco Arming or Disarming Codepad Indicators When ChangingTelco Arming or Disarming Dialing Digits SequenceSetting Stay Mode 2 Zones Satellite Siren Service ModeEvent Memory Recall Mode Turning Telephone Monitor Mode On and OffTelephone Monitor Mode Indications Master Code FunctionsChanging and Deleting User Codes Remote Radio Numbers Displayed by the Codepad IndicatorsMaster Code Functions Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions ICP-CC404 Installation Guide 7.0 Remote Arming by Telephone Remote Arming by TelephoneRemote Connect Alarm Link SoftwareICP-CC404 Installation Guide 8.0 Alarm Link Software Domestic Dialing Alarm Link OptionsICP-CC404 Installation Guide 9.0 Domestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting Transmission Formats ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsDialer Reporting Formats Contact ID FormatExample Reporting in 4 + 2 Express Format Point ID Codes10.1.3 4 + 2 Express Reporting Format + 2 Express Reporting Format+2 Express Transmission Code Descriptions Basic Pager Reporting FormatZone Status Basic Pager Display InformationSubscriber ID Number Zone Status Display DescriptionsPrimary Telephone Number for Receiver 1 and Receiver ICP-CC404 Installation Guide 11.0 Dialer InformationDialer Information System StatusTransmission Format for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverTelco Disarming Sequence Dialing FormatTelco Arming Sequence Ring Count Telephone Line Fault OptionsCall Back Telephone Number Answering Machine BypassDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options ICP-CC404 Installation Guide 13.0 Access Code Access CodeInstaller Code User CodesUser Code Priority Zone Information Day Alarm InformationICP-CC404 Installation Guide 14.0 Zone Information EOL Resistor ValueZone Options Zone ProgrammingZone Operating Information Zone Reporting InformationDelay-2 Zone Zone Programming DefaultsDelay-1 Zone Zone Types Instant ZoneHour Tamper Zone Keyswitch ZoneHour Holdup Zone 12 24-Hour Burglary ZoneKeyswitch Zone Options Delay Alarm ReportingSilent Alarm Latching Arm and Disarm in Away ModeLatching Arm in Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm and Disarm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Siren Swinger Shutdown Count for DialerZone Status Bypass Reports Zone Status Alarm Restore CodeSystem Reporting Information Zone Status Trouble ReportsOpen/Close Reporting Options Zone Status Reporting OptionsOpen/Close Reports Codepad Duress ReportSystem Status AC Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AUX Power Supply Fail Restore Report System Status Low Battery ReportSystem Status Reporting Options System Status Low Battery Restore ReportSystem Status Access Denied Test Reporting TimeTest Reporting Dialer Options ICP-CC404 Installation Guide 16.0 Programmable OutputsProgrammable Outputs Redirecting Outputs to the Codepad BuzzerOutput Event Types Sensor Watch Alarm Day Alarm EnabledAUX Power Supply Fail Codepad Medical AlarmAlarm When in Away Mode Codepad Tamper Access DeniedAlarm When in Stay Mode Mimic System FaultOutput Polarity Normally Low, One-Shot Open with Reset Normally Open, One-Shot Low with ResetNormally Open, One-Shot Low with Alarm Event Type PolaritiesSystem Event Timers Exit Time Entry Guard Timer for Stay ModeDelay Alarm Reporting Time Sensor Watch TimeAuto Disarming Time Auto Arming Pre-Alert TimerAuto Arming Time Kiss-Off Wait TimeSystem and Consumer Options System OptionsPanel Powers Up Disarmed Silent Access Denied Code RetriesSequential Handover Delay Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.8 CP105A Night Arm Station 19.9 PS101 Power Supply Module19.7 CP5 Eight Zone LCD Codepad CP508LW 19.10 TF008 Plug Pack TF008Terminals and Descriptions Terminal DescriptionsGlossary Of Terms Stay Mode Domestic alarm reportsThat an alarm was sent out This mode. Only the installer can program these zonesDiagrams ICP-CC404 Wiring DiagramICP-CC404 Component Overlay 4 not connected Advice to Users SpecificationsWarranty Statement ICP-CC404 Installation Guide 21.0 SpecificationsICP-CC404 Installation Guide 22.0 Programming Sheets Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones 22.0 Programming SheetsICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets Country Codes PRCICP-CC404 Installation Guide Contents ICP-CC404 Installation Guide Index IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02