ICP-CC404 Installation Guide 4.0 System Operations

4.5Arming the System in STAY Mode 2

Use STAY Mode 2 to arm the perimeter and unused areas of the premises to detect an intruder, while at the same time being able to move freely within an automatically isolated area.

You can program zones to automatically isolate in STAY Mode 2 using an Installer Code function (refer to Section 6.1.4 on page 30) or a Master Code function (Section 6.2.5 on page 35).

Entry Guard Timer for STAY Mode

When arming the system in STAY Mode 2, you can use an optional entry timer called Entry Guard Timer for STAY Mode to delay the siren, strobe, and bell outputs if a zone that is not automatically isolated activates an alarm. Entry Guard Timer for STAY Mode is the delay time used for all zones, except 24- Hour zones, when the system is armed in STAY Mode 1 or STAY Mode 2.

If the Entry Guard Timer for STAY Mode is programmed and a zone that was not automatically isolated is activated, the codepad beeps twice per sec until the Entry Guard Timer for STAY Mode expires or the system is disarmed. If the alarm is not reset before Entry Guard Timer for STAY Mode expires, the strobe, bell, and siren outputs are activated into alarm.

Single button disarming from STAY

Mode 2 reports as User Code 16.

To arm the system in STAY Mode 2:

1.Press and hold [0].

2.When two beeps sound, release the button. The STAY indicator lights and the Exit Time starts.

The indicators for any zones programmed to automatically isolate in STAY Mode 2 flash until the Exit Time expires. At the end of Exit Time, the zone indicators turn off and the codepad sounds one short beep.

If a zone is not sealed at the end of Exit Time, the zone is automatically isolated and lights constantly on the remote codepad. The zone becomes an active part of the system again after it is resealed. For example, if a window is open when Exit Time expires, the window does not become an active part of the system until it is closed. Opening the window after Exit Time expires causes an alarm.

Forced Arming

Arming the system when a zone is not sealed is known as forced arming. Refer to Section 14.3.6 Zone Options 2 on page 58 to enable forced arming for each zone.

If the STAY indicator does not light and a long beep sounds when attempting to arm the system, forced arming is not permitted. If this is the case, you must seal all zones or manually isolate them before you can arm the system.

4.6Disarming the System from STAY Mode 2

There are two methods to disarm the system from STAY Mode 2. You can always use the first method. You can use the other method only if Option 4 is enabled in Location 429 (refer to Section 18.6 Consumer Options 2 on page 75).

You cannot use method two unless both

Options 2 and 4 are enabled in

Location 429.

To disarm the system from STAY Mode 2 (method one):

Enter your code and press [STAY].

Two beeps sound and the STAY indicator turns off. The system is now disarmed.

To disarm the system from STAY Mode 2 (method two):

A flashing zone indicator represents a previous alarm in that zone. If this is the case, a valid User Code is required to disarm the system using method one. To enable method two, select Option 4 in Location 429 (refer to Section 18.6 Consumer Options 2 on page 75).

1.Press and hold [0].

2.When two beeps sound, release the button. The STAY indicator turns off and the system is disarmed.

Single button disarming from STAY

Mode 2 reports as User Code16.

20

Bosch Security Systems, Inc. 12/08 F01U089401-02

Image 20
Contents Installation Guide ICP-CC404ICP-CC404 Installation Guide Copyright Notice Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Features ICP-CC404 Installation Guide 1.0 IntroductionIntroduction Quick StartSetting the Date and Time Zone DefaultsExample Zone TypesICP-CC404 Installation Guide 2.0 Programming Codepad IndicatorsProgramming Programming with the Remote CodepadInstaller’s Programming Commands Installer’s Programming Mode CommandsProgramming with the Programming Key Programming Option BitsCommand 958 Enable/Disable Zone Status Mode Command 959 Test the Programming KeyCommand 960 Exit from the Installers Programming Mode Command 963 Copy the Programming Key to the Control PanelCommand 966 Enable or Disable Auto Step Mode Command 964 Erase the Programming KeyCommand 965 Set Up Domestic Dialing Format Command 965 Defaults Example Auto Step Mode EnabledExample Auto Step Mode Disabled ProgrammingDisable Factory Defaults Using this feature is not recommendedICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC404 Installation Guide 3.0 Codepad Indicators System Disarmed Audible IndicatorsICP-CP508LW Eight Zone LCD Codepad Disarming the System from Away Mode Arming the System in Away ModeICP-CC404 Installation Guide 4.0 System Operations System OperationsEntry Guard Timer for Stay Mode Arming the System in Stay ModeDisarming the System from Stay Mode Arming the System in Stay Mode Codepad Duress Alarm Codepad Panic AlarmCodepad Fire Alarm Codepad Medical AlarmFault Analysis Mode Fault DescriptionsFault Indicators Low BatteryTelephone Line Fault Date and TimeSensor Watch Horn Speaker MonitorRemote Radio Transmitter Operations Indications from Remote Radio Transmitter OperationsRemote Radio User Code Priority Levels Changing or Deleting Remote Radio User CodesCodepad Indicators for Remote Radio User Numbers Arming in Away ModeDisarming from Away Mode Arming in Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations Disarming from Stay ModePanic Alarm System Functions Installer Code FunctionsICP-CC404 Installation Guide 6.0 System Functions Codepad Indicators When Changing Phone Numbers Changing Domestic Phone NumbersDomestic Dialing Digits Change Telco Arming or Disarming SequenceCodepad Indicators When Changing Telco Arming or Disarming Dialing DigitsTelco Arming or Disarming SequenceSetting Stay Mode 2 Zones Satellite Siren Service ModeTurning Telephone Monitor Mode On and Off Telephone Monitor Mode IndicationsEvent Memory Recall Mode Master Code FunctionsRemote Radio Numbers Displayed by the Codepad Indicators Master Code FunctionsChanging and Deleting User Codes Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions ICP-CC404 Installation Guide 7.0 Remote Arming by Telephone Remote Arming by TelephoneRemote Connect Alarm Link SoftwareICP-CC404 Installation Guide 8.0 Alarm Link Software Alarm Link Options ICP-CC404 Installation Guide 9.0 Domestic DialingDomestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting ICP-CC404 Installation Guide 10.0 Dialer Reporting Formats Dialer Reporting FormatsTransmission Formats Contact ID FormatPoint ID Codes 10.1.3 4 + 2 Express Reporting FormatExample Reporting in 4 + 2 Express Format + 2 Express Reporting Format+2 Express Transmission Code Descriptions Basic Pager Reporting FormatBasic Pager Display Information Subscriber ID NumberZone Status Zone Status Display DescriptionsICP-CC404 Installation Guide 11.0 Dialer Information Dialer InformationPrimary Telephone Number for Receiver 1 and Receiver System StatusSecondary Telephone Number for Receiver 1 and Receiver Handshake Tone for Receiver 1 and ReceiverTransmission Format for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverTelco Disarming Sequence Dialing FormatTelco Arming Sequence Telephone Line Fault Options Call Back Telephone NumberRing Count Answering Machine BypassDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options Access Code Installer CodeICP-CC404 Installation Guide 13.0 Access Code User CodesUser Code Priority Day Alarm Information ICP-CC404 Installation Guide 14.0 Zone InformationZone Information EOL Resistor ValueZone Programming Zone Operating InformationZone Options Zone Reporting InformationZone Programming Defaults Delay-1 ZoneDelay-2 Zone Zone Types Instant ZoneKeyswitch Zone Hour Holdup ZoneHour Tamper Zone 12 24-Hour Burglary ZoneDelay Alarm Reporting Silent AlarmKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Disarm from Away Mode, Stay Mode 1, or Stay Mode Latching Arm and Disarm in Stay ModeLatching Arm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Siren Swinger Shutdown Count for DialerZone Status Alarm Restore Code System Reporting InformationZone Status Bypass Reports Zone Status Trouble ReportsZone Status Reporting Options Open/Close ReportsOpen/Close Reporting Options Codepad Duress ReportSystem Status AUX Power Supply Fail Report System Status AUX Power Supply Fail Restore ReportSystem Status AC Fail Restore Report System Status Low Battery ReportSystem Status Low Battery Restore Report System Status Access DeniedSystem Status Reporting Options Test Reporting TimeICP-CC404 Installation Guide 16.0 Programmable Outputs Programmable OutputsTest Reporting Dialer Options Redirecting Outputs to the Codepad BuzzerOutput Event Types Day Alarm Enabled AUX Power Supply FailSensor Watch Alarm Codepad Medical AlarmCodepad Tamper Access Denied Alarm When in Stay ModeAlarm When in Away Mode Mimic System FaultOutput Polarity Normally Open, One-Shot Low with Reset Normally Open, One-Shot Low with AlarmNormally Low, One-Shot Open with Reset Event Type PolaritiesSystem Event Timers Entry Guard Timer for Stay Mode Delay Alarm Reporting TimeExit Time Sensor Watch TimeAuto Arming Pre-Alert Timer Auto Arming TimeAuto Disarming Time Kiss-Off Wait TimeSystem and Consumer Options System OptionsSilent Access Denied Code Retries Sequential Handover DelayPanel Powers Up Disarmed Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.9 PS101 Power Supply Module 19.7 CP5 Eight Zone LCD Codepad CP508LW19.8 CP105A Night Arm Station 19.10 TF008 Plug Pack TF008Terminals and Descriptions Terminal DescriptionsGlossary Of Terms Domestic alarm reports That an alarm was sent outStay Mode This mode. Only the installer can program these zonesDiagrams ICP-CC404 Wiring DiagramICP-CC404 Component Overlay 4 not connected Specifications Warranty StatementAdvice to Users ICP-CC404 Installation Guide 21.0 SpecificationsICP-CC404 Installation Guide 22.0 Programming Sheets Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones 22.0 Programming SheetsICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets Country Codes PRCICP-CC404 Installation Guide Contents ICP-CC404 Installation Guide Index IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02