Bosch Appliances ICP-CC404 manual Setting Stay Mode 2 Zones

Page 35

ICP-CC404 Installation Guide 6.0 System Functions

If there is no Telco disarming sequence programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the sequence is shown.

3.Press [STAY][2 6 1][STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

You can suspend the Telco disarming sequence at any time.

To disable the Telco disarming sequence:

Enter your Master Code and press [3][AWAY][2] [AWAY][STAY][4][AWAY].

To program the Telco arming sequence – easy call forward (immediate on):

1.Enter your Master Code and press [3][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Press [1][AWAY] button to change the Telco arming sequence. Three beeps sound.

If a call forwarding sequence is already programmed, the sequence appears one digit at a time using the remote codepad indicators. Refer to Table 30 for the indicators and their meanings.

If there is no call forward sequence programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the call forward sequence is displayed.

3.Press [STAY][1 2 1] and enter the phone number to which you want calls from the control panel diverted.

4.Press [STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

Example

If you want to automatically divert all incoming calls to another telephone number (for example, 9672 1777) when the system is armed in AWAY Mode, enter:

[2 5 8 0 3][AWAY][1][AWAY][STAY] [1 2 1 9 6 7 2 1 7 7 7][STAY][2][AWAY]

You can suspend the Telco arming sequence at any time.

To disable the Telco arming sequence:

Enter your Master Code and press [3][AWAY][1] [AWAY][STAY][4][AWAY].

To program the Telco disarming sequence – easy call forward (immediate off):

1.Enter your Master Code and press [3][AWAY]. Three beeps sound and the STAY and AWAY indicators flash.

2.Press [2][AWAY] to change the Telco disarming sequence.

Three beeps sound.

If a Telco disarming sequence is already programmed, the sequence appears one digit at a time using the remote codepad indicators. Refer to Table 30 on page 34 for the indicators and their meanings.

If there is no Telco disarming sequence programmed, an additional two beeps sound after entering this mode. These two beeps normally sound after the last digit of the sequence is shown.

3.Press [STAY][2 2 1][STAY][2][AWAY].

Two beeps sound and the system returns to the disarmed state.

You can suspend the Telco disarming sequence at any time.

To disable the Telco disarming sequence:

Enter your Master Code and press [3][AWAY][2] [AWAY][STAY][4][AWAY].

6.2.5Setting STAY Mode 2 Zones

This function allows the Master Code holder to select the zones that are automatically isolated when the system is armed in STAY Mode 2.

To arm the system in STAY Mode 2, press and hold

[0]until two beeps sound. Refer to Section 6.3.3 on page 37 or Section 4.5 Arming the System in STAY Mode 2 on page 20 for more information.

To set STAY Mode 2 zones:

1.Enter your Master Code and press [4][AWAY]. Three beeps sound and the STAY indicator flashes.

2.Enter the number of the zone you want to automatically isolate and press [STAY]. The corresponding zone indicator flashes.

3.Repeat Step 2 to select each zone.

As you select each zone to isolate, the corresponding zone indicator flashes. If you make a mistake, enter the incorrect zone number and press [STAY]. This zone is no longer selected to be isolated and the zone indicator is extinguished.

4.Press [AWAY].

Two beeps sound and the system returns to the disarmed state.

The indicators for the zones you selected and the STAY indicator turn off.

Example

If you want to select zones 2, 5, and 6, enter:

[2 5 8 0 4][AWAY][2][STAY][5][STAY][6][STAY] [AWAY]

Bosch Security Systems, Inc. 12/08 F01U089401-02

35

Image 35
Contents ICP-CC404 Installation GuideCopyright Notice ICP-CC404 Installation Guide Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Quick Start FeaturesICP-CC404 Installation Guide 1.0 Introduction IntroductionZone Types Setting the Date and TimeZone Defaults ExampleProgramming with the Remote Codepad ICP-CC404 Installation Guide 2.0 ProgrammingCodepad Indicators ProgrammingProgramming Option Bits Installer’s Programming CommandsInstaller’s Programming Mode Commands Programming with the Programming KeyCommand 959 Test the Programming Key Command 958 Enable/Disable Zone Status ModeCommand 963 Copy the Programming Key to the Control Panel Command 960 Exit from the Installers Programming ModeCommand 966 Enable or Disable Auto Step Mode Command 964 Erase the Programming KeyCommand 965 Set Up Domestic Dialing Format Programming Command 965 DefaultsExample Auto Step Mode Enabled Example Auto Step Mode DisabledUsing this feature is not recommended Disable Factory DefaultsICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC404 Installation Guide 3.0 Codepad Indicators System Disarmed Audible IndicatorsICP-CP508LW Eight Zone LCD Codepad System Operations Disarming the System from Away ModeArming the System in Away Mode ICP-CC404 Installation Guide 4.0 System OperationsEntry Guard Timer for Stay Mode Arming the System in Stay ModeDisarming the System from Stay Mode Arming the System in Stay Mode Codepad Medical Alarm Codepad Duress AlarmCodepad Panic Alarm Codepad Fire AlarmLow Battery Fault Analysis ModeFault Descriptions Fault IndicatorsHorn Speaker Monitor Telephone Line FaultDate and Time Sensor WatchChanging or Deleting Remote Radio User Codes Remote Radio Transmitter OperationsIndications from Remote Radio Transmitter Operations Remote Radio User Code Priority LevelsArming in Stay Mode Codepad Indicators for Remote Radio User NumbersArming in Away Mode Disarming from Away ModeFour-Channel Remote Radio Hand- Held Transmitter Operations Disarming from Stay ModePanic Alarm System Functions Installer Code FunctionsICP-CC404 Installation Guide 6.0 System Functions Change Telco Arming or Disarming Sequence Codepad Indicators When Changing Phone NumbersChanging Domestic Phone Numbers Domestic Dialing DigitsSequence Codepad Indicators When ChangingTelco Arming or Disarming Dialing Digits Telco Arming or DisarmingSatellite Siren Service Mode Setting Stay Mode 2 ZonesMaster Code Functions Turning Telephone Monitor Mode On and OffTelephone Monitor Mode Indications Event Memory Recall ModeChanging and Deleting Remote Radio User Codes Remote Radio Numbers Displayed by the Codepad IndicatorsMaster Code Functions Changing and Deleting User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions Remote Arming by Telephone ICP-CC404 Installation Guide 7.0 Remote Arming by TelephoneRemote Connect Alarm Link SoftwareICP-CC404 Installation Guide 8.0 Alarm Link Software Domestic Dialing Function Alarm Link OptionsICP-CC404 Installation Guide 9.0 Domestic Dialing Domestic DialingSetting Up and Programming Domestic Reporting Contact ID Format ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsDialer Reporting Formats Transmission Formats+ 2 Express Reporting Format Point ID Codes10.1.3 4 + 2 Express Reporting Format Example Reporting in 4 + 2 Express FormatBasic Pager Reporting Format +2 Express Transmission Code DescriptionsZone Status Display Descriptions Basic Pager Display InformationSubscriber ID Number Zone StatusSystem Status ICP-CC404 Installation Guide 11.0 Dialer InformationDialer Information Primary Telephone Number for Receiver 1 and ReceiverSubscriber ID Number for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Transmission Format for Receiver 1 and ReceiverTelco Disarming Sequence Dialing FormatTelco Arming Sequence Answering Machine Bypass Telephone Line Fault OptionsCall Back Telephone Number Ring CountDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options User Codes Access CodeInstaller Code ICP-CC404 Installation Guide 13.0 Access CodeUser Code Priority EOL Resistor Value Day Alarm InformationICP-CC404 Installation Guide 14.0 Zone Information Zone InformationZone Reporting Information Zone ProgrammingZone Operating Information Zone OptionsZone Types Instant Zone Zone Programming DefaultsDelay-1 Zone Delay-2 Zone12 24-Hour Burglary Zone Keyswitch ZoneHour Holdup Zone Hour Tamper ZoneLatching Arm and Disarm in Away Mode Delay Alarm ReportingSilent Alarm Keyswitch Zone OptionsLatching Disarm from Stay Mode 1 or Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm and Disarm in Stay Mode Latching Arm in Stay ModeSwinger Shutdown Count for Dialer Swinger Shutdown Count for SirenZone Status Trouble Reports Zone Status Alarm Restore CodeSystem Reporting Information Zone Status Bypass ReportsCodepad Duress Report Zone Status Reporting OptionsOpen/Close Reports Open/Close Reporting OptionsSystem Status Low Battery Report System Status AUX Power Supply Fail ReportSystem Status AUX Power Supply Fail Restore Report System Status AC Fail Restore ReportTest Reporting Time System Status Low Battery Restore ReportSystem Status Access Denied System Status Reporting OptionsRedirecting Outputs to the Codepad Buzzer ICP-CC404 Installation Guide 16.0 Programmable OutputsProgrammable Outputs Test Reporting Dialer OptionsOutput Event Types Codepad Medical Alarm Day Alarm EnabledAUX Power Supply Fail Sensor Watch AlarmMimic System Fault Codepad Tamper Access DeniedAlarm When in Stay Mode Alarm When in Away ModeOutput Polarity Event Type Polarities Normally Open, One-Shot Low with ResetNormally Open, One-Shot Low with Alarm Normally Low, One-Shot Open with ResetSystem Event Timers Sensor Watch Time Entry Guard Timer for Stay ModeDelay Alarm Reporting Time Exit TimeKiss-Off Wait Time Auto Arming Pre-Alert TimerAuto Arming Time Auto Disarming TimeSystem Options System and Consumer OptionsArm/Disarm Tracking on Power Up Silent Access Denied Code RetriesSequential Handover Delay Panel Powers Up DisarmedConsumer Options Optional Equipment 19.10 TF008 Plug Pack TF008 19.9 PS101 Power Supply Module19.7 CP5 Eight Zone LCD Codepad CP508LW 19.8 CP105A Night Arm StationTerminal Descriptions Terminals and DescriptionsGlossary Of Terms This mode. Only the installer can program these zones Domestic alarm reportsThat an alarm was sent out Stay ModeICP-CC404 Wiring Diagram DiagramsICP-CC404 Component Overlay 4 not connected ICP-CC404 Installation Guide 21.0 Specifications SpecificationsWarranty Statement Advice to UsersProgramming Sheets ICP-CC404 Installation Guide 22.0 Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones Programming Sheets 22.0ICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets PRC Country CodesICP-CC404 Installation Guide Contents Index ICP-CC404 Installation Guide IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02