Bosch Appliances ICP-CC404 19.7 CP5 Eight Zone LCD Codepad CP508LW, 19.8 CP105A Night Arm Station

Page 77

ICP-CC404 Installation Guide 19.0 Optional Equipment

19.7CP5 Eight Zone LCD Codepad (CP508LW)

This codepad operates with the range of control panels. This codepad has a fixed icon display and provides indications for up to eight zones.

19.8CP105A Night Arm Station

The night arm station has a panic button and allows the user to arm and disarm the system in STAY Mode 1 from a bedroom or sitting room. Enable the night arm station to operate with the system by selecting Option 8 in Location 427 (refer to Section 18.4 System Options 4 on page 74).

19.9PS101 Power Supply Module

The PS101 Power Supply Module provides 13.8 VDC at currents up to 1 A. Use the module with the TF008 18 VAC plug pack.

The module provides standard, fully short-circuit proof, power out, and battery charging terminals, and a DC LED indicator. If the application requires an uninterruptible power supply, a rechargeable sealed lead-acid battery can be installed. If there is a mains failure, the power supply switches to battery power without interrupting the supply to the load.

19.10 TF008 Plug Pack (TF008)

The TF008 plug pack is used with control panels. The plug pack includes built-in thermal fuses that blow during overload or fault conditions to eliminate a possible fire threat due to excessive heat buildup inside the casing.

The plug pack incorporates a three-wire flying lead that enables a mains earth connection between the equipment and the plug pack. This connection might be required for lightning protection on equipment connected to phone lines or for safety reasons such as earthing of metal enclosures.

Bosch Security Systems, Inc. 12/08 F01U089401-02

77

Image 77
Contents ICP-CC404 Installation GuideCopyright Notice ICP-CC404 Installation Guide Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables ICP-CC404 Installation Guide 1.0 Introduction FeaturesIntroduction Quick StartZone Defaults Setting the Date and TimeExample Zone TypesCodepad Indicators ICP-CC404 Installation Guide 2.0 ProgrammingProgramming Programming with the Remote CodepadInstaller’s Programming Mode Commands Installer’s Programming CommandsProgramming with the Programming Key Programming Option BitsCommand 959 Test the Programming Key Command 958 Enable/Disable Zone Status ModeCommand 963 Copy the Programming Key to the Control Panel Command 960 Exit from the Installers Programming ModeCommand 966 Enable or Disable Auto Step Mode Command 964 Erase the Programming KeyCommand 965 Set Up Domestic Dialing Format Example Auto Step Mode Enabled Command 965 DefaultsExample Auto Step Mode Disabled ProgrammingUsing this feature is not recommended Disable Factory DefaultsICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC404 Installation Guide 3.0 Codepad Indicators System Disarmed Audible IndicatorsICP-CP508LW Eight Zone LCD Codepad Arming the System in Away Mode Disarming the System from Away ModeICP-CC404 Installation Guide 4.0 System Operations System OperationsEntry Guard Timer for Stay Mode Arming the System in Stay ModeDisarming the System from Stay Mode Arming the System in Stay Mode Codepad Panic Alarm Codepad Duress AlarmCodepad Fire Alarm Codepad Medical AlarmFault Descriptions Fault Analysis ModeFault Indicators Low BatteryDate and Time Telephone Line FaultSensor Watch Horn Speaker MonitorIndications from Remote Radio Transmitter Operations Remote Radio Transmitter OperationsRemote Radio User Code Priority Levels Changing or Deleting Remote Radio User CodesArming in Away Mode Codepad Indicators for Remote Radio User NumbersDisarming from Away Mode Arming in Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations Disarming from Stay ModePanic Alarm System Functions Installer Code FunctionsICP-CC404 Installation Guide 6.0 System Functions Changing Domestic Phone Numbers Codepad Indicators When Changing Phone NumbersDomestic Dialing Digits Change Telco Arming or Disarming SequenceTelco Arming or Disarming Dialing Digits Codepad Indicators When ChangingTelco Arming or Disarming SequenceSatellite Siren Service Mode Setting Stay Mode 2 ZonesTelephone Monitor Mode Indications Turning Telephone Monitor Mode On and OffEvent Memory Recall Mode Master Code FunctionsMaster Code Functions Remote Radio Numbers Displayed by the Codepad IndicatorsChanging and Deleting User Codes Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions Remote Arming by Telephone ICP-CC404 Installation Guide 7.0 Remote Arming by TelephoneRemote Connect Alarm Link SoftwareICP-CC404 Installation Guide 8.0 Alarm Link Software ICP-CC404 Installation Guide 9.0 Domestic Dialing Alarm Link OptionsDomestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting Dialer Reporting Formats ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsTransmission Formats Contact ID Format10.1.3 4 + 2 Express Reporting Format Point ID CodesExample Reporting in 4 + 2 Express Format + 2 Express Reporting FormatBasic Pager Reporting Format +2 Express Transmission Code DescriptionsSubscriber ID Number Basic Pager Display InformationZone Status Zone Status Display DescriptionsDialer Information ICP-CC404 Installation Guide 11.0 Dialer InformationPrimary Telephone Number for Receiver 1 and Receiver System StatusHandshake Tone for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverTransmission Format for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverTelco Disarming Sequence Dialing FormatTelco Arming Sequence Call Back Telephone Number Telephone Line Fault OptionsRing Count Answering Machine BypassDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options Installer Code Access CodeICP-CC404 Installation Guide 13.0 Access Code User CodesUser Code Priority ICP-CC404 Installation Guide 14.0 Zone Information Day Alarm InformationZone Information EOL Resistor ValueZone Operating Information Zone ProgrammingZone Options Zone Reporting InformationDelay-1 Zone Zone Programming DefaultsDelay-2 Zone Zone Types Instant ZoneHour Holdup Zone Keyswitch ZoneHour Tamper Zone 12 24-Hour Burglary ZoneSilent Alarm Delay Alarm ReportingKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Arm and Disarm in Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Dialer Swinger Shutdown Count for SirenSystem Reporting Information Zone Status Alarm Restore CodeZone Status Bypass Reports Zone Status Trouble ReportsOpen/Close Reports Zone Status Reporting OptionsOpen/Close Reporting Options Codepad Duress ReportSystem Status AUX Power Supply Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AC Fail Restore Report System Status Low Battery ReportSystem Status Access Denied System Status Low Battery Restore ReportSystem Status Reporting Options Test Reporting TimeProgrammable Outputs ICP-CC404 Installation Guide 16.0 Programmable OutputsTest Reporting Dialer Options Redirecting Outputs to the Codepad BuzzerOutput Event Types AUX Power Supply Fail Day Alarm EnabledSensor Watch Alarm Codepad Medical AlarmAlarm When in Stay Mode Codepad Tamper Access DeniedAlarm When in Away Mode Mimic System FaultOutput Polarity Normally Open, One-Shot Low with Alarm Normally Open, One-Shot Low with ResetNormally Low, One-Shot Open with Reset Event Type PolaritiesSystem Event Timers Delay Alarm Reporting Time Entry Guard Timer for Stay ModeExit Time Sensor Watch TimeAuto Arming Time Auto Arming Pre-Alert TimerAuto Disarming Time Kiss-Off Wait TimeSystem Options System and Consumer OptionsSequential Handover Delay Silent Access Denied Code RetriesPanel Powers Up Disarmed Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.7 CP5 Eight Zone LCD Codepad CP508LW 19.9 PS101 Power Supply Module19.8 CP105A Night Arm Station 19.10 TF008 Plug Pack TF008Terminal Descriptions Terminals and DescriptionsGlossary Of Terms That an alarm was sent out Domestic alarm reportsStay Mode This mode. Only the installer can program these zonesICP-CC404 Wiring Diagram DiagramsICP-CC404 Component Overlay 4 not connected Warranty Statement SpecificationsAdvice to Users ICP-CC404 Installation Guide 21.0 SpecificationsProgramming Sheets ICP-CC404 Installation Guide 22.0 Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones Programming Sheets 22.0ICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets PRC Country CodesICP-CC404 Installation Guide Contents Index ICP-CC404 Installation Guide IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02