Bosch Appliances ICP-CC404 manual Output Polarity

Page 68

ICP-CC404 Installation Guide 16.0 Programmable Outputs

2,13 Radio Control Output 1 – Not in AWAY Mode

This output operates when the [DOOR] button on the four-channel hand-held transmitter is activated. The output does not operate when the system is armed in AWAY Mode.

2,14 Radio Control Output 2 – Not in AWAY Mode

This output operates when the [AUX] button on the four-channel hand-held transmitter is activated. The output does not operate when the system is armed in AWAY Mode.

2,15 Communications Failure after Three Unsuccessful Calls

This output operates after the communication dialer makes three unsuccessful calls to the base station receiver. The output resets when all messages are sent (that is, when the message buffer is empty or when all possible attempts are made).

3,0 Communications Failure

This output operates after the communication dialer makes all possible attempts to reach the base station receiver. The output resets when the first kiss-off is received. This output does not operate for domestic formats.

3,1 Dialer Disabled

This output operates when the Dialer reporting functions allowed Option 1 in Location 177 are not selected (refer to Section 12.1 Dialer Options 1 on page 50). The output resets when Option 1 is selected.

3,2 Dialer Active

This output operates when the communication dialer is online. The output resets when the communication dialer releases the telephone line.

3,3 Ring Detect

This output operates when the control panel detects an incoming call. The output resets when the ringing stops or when the call is answered.

3,5 Mimic Zone 1

3,6 Mimic Zone 2

3,7 Mimic Zone 3

3,8 Mimic Zone 4

3,9 Mimic Zone 5

3,10 Mimic Zone 6

3,11 Mimic Zone 7

3,12 Mimic Zone 8

These output types mimic the zone inputs. The output operates when the zone is unsealed and resets when the zone is sealed. They operate regardless of the selected zone type (for example, a zone programmed as Not Used can still operate a mimic output). This feature operates when the system is armed or disarmed.

4,5 Global Chime

This output operates when any Chime zones are activated. The output resets when the zone is resealed. Refer to Section 14.3.1 Zone Types on page 55 for more information.

4,6 Zone Not Sealed

This output operates when a Burglary Zone is unsealed. Chime zones do not operate this output.

4,7 Zone Not Sealed after Exit Time

This output operates at the end of Exit Time if a Burglary Zone is unsealed. The output resets when all zones are sealed or the system is disarmed. Chime zones do not operate this output.

4,9 AC Mains 60 Hz or 50 Hz

This output is activated when the AC mains supply frequency is 60 Hz. The output resets if the AC mains supply returns to 50 Hz.

16.3Output Polarity

There are fifteen different polarities. Each polarity is designated by a number that you program into the third location for the output.

68

Bosch Security Systems, Inc. 12/08 F01U089401-02

Image 68
Contents Installation Guide ICP-CC404ICP-CC404 Installation Guide Copyright Notice Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Features ICP-CC404 Installation Guide 1.0 IntroductionIntroduction Quick StartSetting the Date and Time Zone DefaultsExample Zone TypesICP-CC404 Installation Guide 2.0 Programming Codepad IndicatorsProgramming Programming with the Remote CodepadInstaller’s Programming Commands Installer’s Programming Mode CommandsProgramming with the Programming Key Programming Option BitsCommand 958 Enable/Disable Zone Status Mode Command 959 Test the Programming KeyCommand 960 Exit from the Installers Programming Mode Command 963 Copy the Programming Key to the Control PanelCommand 966 Enable or Disable Auto Step Mode Command 964 Erase the Programming KeyCommand 965 Set Up Domestic Dialing Format Command 965 Defaults Example Auto Step Mode EnabledExample Auto Step Mode Disabled ProgrammingDisable Factory Defaults Using this feature is not recommendedICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC404 Installation Guide 3.0 Codepad Indicators System Disarmed Audible IndicatorsICP-CP508LW Eight Zone LCD Codepad Disarming the System from Away Mode Arming the System in Away ModeICP-CC404 Installation Guide 4.0 System Operations System OperationsEntry Guard Timer for Stay Mode Arming the System in Stay ModeDisarming the System from Stay Mode Arming the System in Stay Mode Codepad Duress Alarm Codepad Panic AlarmCodepad Fire Alarm Codepad Medical AlarmFault Analysis Mode Fault DescriptionsFault Indicators Low BatteryTelephone Line Fault Date and TimeSensor Watch Horn Speaker MonitorRemote Radio Transmitter Operations Indications from Remote Radio Transmitter OperationsRemote Radio User Code Priority Levels Changing or Deleting Remote Radio User CodesCodepad Indicators for Remote Radio User Numbers Arming in Away ModeDisarming from Away Mode Arming in Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations Disarming from Stay ModePanic Alarm System Functions Installer Code FunctionsICP-CC404 Installation Guide 6.0 System Functions Codepad Indicators When Changing Phone Numbers Changing Domestic Phone NumbersDomestic Dialing Digits Change Telco Arming or Disarming SequenceCodepad Indicators When Changing Telco Arming or Disarming Dialing DigitsTelco Arming or Disarming SequenceSetting Stay Mode 2 Zones Satellite Siren Service ModeTurning Telephone Monitor Mode On and Off Telephone Monitor Mode IndicationsEvent Memory Recall Mode Master Code FunctionsRemote Radio Numbers Displayed by the Codepad Indicators Master Code FunctionsChanging and Deleting User Codes Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions ICP-CC404 Installation Guide 7.0 Remote Arming by Telephone Remote Arming by TelephoneRemote Connect Alarm Link SoftwareICP-CC404 Installation Guide 8.0 Alarm Link Software Alarm Link Options ICP-CC404 Installation Guide 9.0 Domestic DialingDomestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting ICP-CC404 Installation Guide 10.0 Dialer Reporting Formats Dialer Reporting FormatsTransmission Formats Contact ID FormatPoint ID Codes 10.1.3 4 + 2 Express Reporting FormatExample Reporting in 4 + 2 Express Format + 2 Express Reporting Format+2 Express Transmission Code Descriptions Basic Pager Reporting FormatBasic Pager Display Information Subscriber ID NumberZone Status Zone Status Display DescriptionsICP-CC404 Installation Guide 11.0 Dialer Information Dialer InformationPrimary Telephone Number for Receiver 1 and Receiver System StatusSecondary Telephone Number for Receiver 1 and Receiver Handshake Tone for Receiver 1 and ReceiverTransmission Format for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverTelco Disarming Sequence Dialing FormatTelco Arming Sequence Telephone Line Fault Options Call Back Telephone NumberRing Count Answering Machine BypassDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options Access Code Installer CodeICP-CC404 Installation Guide 13.0 Access Code User CodesUser Code Priority Day Alarm Information ICP-CC404 Installation Guide 14.0 Zone InformationZone Information EOL Resistor ValueZone Programming Zone Operating InformationZone Options Zone Reporting InformationZone Programming Defaults Delay-1 ZoneDelay-2 Zone Zone Types Instant ZoneKeyswitch Zone Hour Holdup ZoneHour Tamper Zone 12 24-Hour Burglary ZoneDelay Alarm Reporting Silent AlarmKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Disarm from Away Mode, Stay Mode 1, or Stay Mode Latching Arm and Disarm in Stay ModeLatching Arm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Siren Swinger Shutdown Count for DialerZone Status Alarm Restore Code System Reporting InformationZone Status Bypass Reports Zone Status Trouble ReportsZone Status Reporting Options Open/Close ReportsOpen/Close Reporting Options Codepad Duress ReportSystem Status AUX Power Supply Fail Report System Status AUX Power Supply Fail Restore ReportSystem Status AC Fail Restore Report System Status Low Battery ReportSystem Status Low Battery Restore Report System Status Access DeniedSystem Status Reporting Options Test Reporting TimeICP-CC404 Installation Guide 16.0 Programmable Outputs Programmable OutputsTest Reporting Dialer Options Redirecting Outputs to the Codepad BuzzerOutput Event Types Day Alarm Enabled AUX Power Supply FailSensor Watch Alarm Codepad Medical AlarmCodepad Tamper Access Denied Alarm When in Stay ModeAlarm When in Away Mode Mimic System FaultOutput Polarity Normally Open, One-Shot Low with Reset Normally Open, One-Shot Low with AlarmNormally Low, One-Shot Open with Reset Event Type PolaritiesSystem Event Timers Entry Guard Timer for Stay Mode Delay Alarm Reporting TimeExit Time Sensor Watch TimeAuto Arming Pre-Alert Timer Auto Arming TimeAuto Disarming Time Kiss-Off Wait TimeSystem and Consumer Options System OptionsSilent Access Denied Code Retries Sequential Handover DelayPanel Powers Up Disarmed Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.9 PS101 Power Supply Module 19.7 CP5 Eight Zone LCD Codepad CP508LW19.8 CP105A Night Arm Station 19.10 TF008 Plug Pack TF008Terminals and Descriptions Terminal DescriptionsGlossary Of Terms Domestic alarm reports That an alarm was sent outStay Mode This mode. Only the installer can program these zonesDiagrams ICP-CC404 Wiring DiagramICP-CC404 Component Overlay 4 not connected Specifications Warranty StatementAdvice to Users ICP-CC404 Installation Guide 21.0 SpecificationsICP-CC404 Installation Guide 22.0 Programming Sheets Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones 22.0 Programming SheetsICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets Country Codes PRCICP-CC404 Installation Guide Contents ICP-CC404 Installation Guide Index IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02