Bosch Appliances ICP-CC404 Programming, Command 965 Defaults, Example Auto Step Mode Enabled

Page 14

 

ICP-CC404 Installation Guide

2.0

Programming

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 6:

Command 965 Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location

 

Description

 

Default Value

Setting

 

 

 

 

 

 

 

 

 

032

 

Handshake Tone for Receiver 1

1

(Handshake Tone)

 

 

033

 

Transmission Format

 

4

(Domestic)

 

 

 

 

 

 

 

 

 

 

034 to 039

 

Subscriber ID Number

 

0, 0, 0, 0, 0, 1

(1 Beep)

 

 

332

 

Zone Status Reporting Options

2

(Receiver 2 only)

 

 

333 and 334

 

Open/Close Reports

 

11, 12

(Open/Close Reports)

 

 

335

 

Open/Close Reporting Options

2

(Receiver 2 only)

 

 

 

 

 

 

 

 

 

356 to 358

 

System Status – Access Denied

6, 7, 12

(Access Denied)

 

 

359

 

System Status Reporting Options

2

(Receiver 2 only)

 

 

360 to 366

 

Test Report Time

 

0, 0, 0, 0, 7, 1, 0

(Test Reports)

 

 

367

 

Test Reporting Dialer Options

1

(Receiver 1 only)

 

Example (Auto Step Mode Enabled)

To enter the Primary Telephone Number 02 (pause)

9672 1055 when Auto Step Mode is enabled:

1.Press [0 #].

You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).

2.To program the number, press:

[10 * 2 * 13 * 9 * 6 * 7 * 2 * 1 * 10 * 5 * 5 * 0*]

Example (Auto Step Mode Disabled)

To enter the Primary Telephone Number 02 (pause)

9672 1055 when Auto Step Mode is disabled:

1.Press [0 #].

You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).

2.To program the number, press:

[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * # 10 * # 5 * # 5 * # 0 *]

2.4.10Command 999 – Display the Panel Type or Software Version Number

When using the remote codepad, this command shows the version of the control panel. Because different control panels use the same printed circuit board (PCB), it is difficult to determine the control panel the PCB is set to.

To show the control panel type or software version number:

1.Enter the Installer Code (the default is 1234) and press [#] to enter Installer’s Programming Mode. Two beeps sound and the remote codepad shows the data programmed in Location 000.

If you are using the remote codepad, the STAY and AWAY indicators flash to indicate you entered Installer’s Programming Mode.

2.Enter [9 9 9 #]. Two beeps sound.

If you are using the remote codepad, the codepad displays a zone indicator corresponding to the control panel type. Refer to Table 7 for more information.

Table 7: Control Panel Type

Indicator

Control Panel Type

4ICP-CC404

8ICP-CC408 ICP-CC488

3.Press [#] to exit from this command and return to the Installer’s Programming Mode.

4.Enter [9 6 0 #] to exit from the Installer's Programming Mode.

Two sound and the system returns to the disarmed state.

If you are using the remote codepad, the STAY and AWAY indicators turn off to indicate the system is disarmed.

14

Bosch Security Systems, Inc. 12/08 F01U089401-02

Image 14
Contents Installation Guide ICP-CC404ICP-CC404 Installation Guide Copyright Notice Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Introduction FeaturesICP-CC404 Installation Guide 1.0 Introduction Quick StartExample Setting the Date and TimeZone Defaults Zone TypesProgramming ICP-CC404 Installation Guide 2.0 ProgrammingCodepad Indicators Programming with the Remote CodepadProgramming with the Programming Key Installer’s Programming CommandsInstaller’s Programming Mode Commands Programming Option BitsCommand 958 Enable/Disable Zone Status Mode Command 959 Test the Programming KeyCommand 960 Exit from the Installers Programming Mode Command 963 Copy the Programming Key to the Control PanelCommand 966 Enable or Disable Auto Step Mode Command 964 Erase the Programming KeyCommand 965 Set Up Domestic Dialing Format Example Auto Step Mode Disabled Command 965 DefaultsExample Auto Step Mode Enabled ProgrammingDisable Factory Defaults Using this feature is not recommendedICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC404 Installation Guide 3.0 Codepad Indicators System Disarmed Audible IndicatorsICP-CP508LW Eight Zone LCD Codepad ICP-CC404 Installation Guide 4.0 System Operations Disarming the System from Away ModeArming the System in Away Mode System OperationsEntry Guard Timer for Stay Mode Arming the System in Stay ModeDisarming the System from Stay Mode Arming the System in Stay Mode Codepad Fire Alarm Codepad Duress AlarmCodepad Panic Alarm Codepad Medical AlarmFault Indicators Fault Analysis ModeFault Descriptions Low BatterySensor Watch Telephone Line FaultDate and Time Horn Speaker MonitorRemote Radio User Code Priority Levels Remote Radio Transmitter OperationsIndications from Remote Radio Transmitter Operations Changing or Deleting Remote Radio User CodesDisarming from Away Mode Codepad Indicators for Remote Radio User NumbersArming in Away Mode Arming in Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations Disarming from Stay ModePanic Alarm System Functions Installer Code FunctionsICP-CC404 Installation Guide 6.0 System Functions Domestic Dialing Digits Codepad Indicators When Changing Phone NumbersChanging Domestic Phone Numbers Change Telco Arming or Disarming SequenceTelco Arming or Disarming Codepad Indicators When ChangingTelco Arming or Disarming Dialing Digits SequenceSetting Stay Mode 2 Zones Satellite Siren Service ModeEvent Memory Recall Mode Turning Telephone Monitor Mode On and OffTelephone Monitor Mode Indications Master Code FunctionsChanging and Deleting User Codes Remote Radio Numbers Displayed by the Codepad IndicatorsMaster Code Functions Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions ICP-CC404 Installation Guide 7.0 Remote Arming by Telephone Remote Arming by TelephoneRemote Connect Alarm Link SoftwareICP-CC404 Installation Guide 8.0 Alarm Link Software Domestic Dialing Alarm Link OptionsICP-CC404 Installation Guide 9.0 Domestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting Transmission Formats ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsDialer Reporting Formats Contact ID FormatExample Reporting in 4 + 2 Express Format Point ID Codes10.1.3 4 + 2 Express Reporting Format + 2 Express Reporting Format+2 Express Transmission Code Descriptions Basic Pager Reporting FormatZone Status Basic Pager Display InformationSubscriber ID Number Zone Status Display DescriptionsPrimary Telephone Number for Receiver 1 and Receiver ICP-CC404 Installation Guide 11.0 Dialer InformationDialer Information System StatusTransmission Format for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverTelco Disarming Sequence Dialing FormatTelco Arming Sequence Ring Count Telephone Line Fault OptionsCall Back Telephone Number Answering Machine BypassDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options ICP-CC404 Installation Guide 13.0 Access Code Access CodeInstaller Code User CodesUser Code Priority Zone Information Day Alarm InformationICP-CC404 Installation Guide 14.0 Zone Information EOL Resistor ValueZone Options Zone ProgrammingZone Operating Information Zone Reporting InformationDelay-2 Zone Zone Programming DefaultsDelay-1 Zone Zone Types Instant ZoneHour Tamper Zone Keyswitch ZoneHour Holdup Zone 12 24-Hour Burglary ZoneKeyswitch Zone Options Delay Alarm ReportingSilent Alarm Latching Arm and Disarm in Away ModeLatching Arm in Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm and Disarm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Siren Swinger Shutdown Count for DialerZone Status Bypass Reports Zone Status Alarm Restore CodeSystem Reporting Information Zone Status Trouble ReportsOpen/Close Reporting Options Zone Status Reporting OptionsOpen/Close Reports Codepad Duress ReportSystem Status AC Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AUX Power Supply Fail Restore Report System Status Low Battery ReportSystem Status Reporting Options System Status Low Battery Restore ReportSystem Status Access Denied Test Reporting TimeTest Reporting Dialer Options ICP-CC404 Installation Guide 16.0 Programmable OutputsProgrammable Outputs Redirecting Outputs to the Codepad BuzzerOutput Event Types Sensor Watch Alarm Day Alarm EnabledAUX Power Supply Fail Codepad Medical AlarmAlarm When in Away Mode Codepad Tamper Access DeniedAlarm When in Stay Mode Mimic System FaultOutput Polarity Normally Low, One-Shot Open with Reset Normally Open, One-Shot Low with ResetNormally Open, One-Shot Low with Alarm Event Type PolaritiesSystem Event Timers Exit Time Entry Guard Timer for Stay ModeDelay Alarm Reporting Time Sensor Watch TimeAuto Disarming Time Auto Arming Pre-Alert TimerAuto Arming Time Kiss-Off Wait TimeSystem and Consumer Options System OptionsPanel Powers Up Disarmed Silent Access Denied Code RetriesSequential Handover Delay Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.8 CP105A Night Arm Station 19.9 PS101 Power Supply Module19.7 CP5 Eight Zone LCD Codepad CP508LW 19.10 TF008 Plug Pack TF008Terminals and Descriptions Terminal DescriptionsGlossary Of Terms Stay Mode Domestic alarm reportsThat an alarm was sent out This mode. Only the installer can program these zonesDiagrams ICP-CC404 Wiring DiagramICP-CC404 Component Overlay 4 not connected Advice to Users SpecificationsWarranty Statement ICP-CC404 Installation Guide 21.0 SpecificationsICP-CC404 Installation Guide 22.0 Programming Sheets Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones 22.0 Programming SheetsICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets Country Codes PRCICP-CC404 Installation Guide Contents ICP-CC404 Installation Guide Index IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02