Bosch Appliances ICP-CC404 Zone Programming Defaults, Zone Types Instant Zone, Handover Zone

Page 55

ICP-CC404 Installation Guide 14.0 Zone Information

The Zone Report Code determines whether the control panel sends Alarm Reports for the zone. Refer to Section 14.3.7 Zone Report Code on page 59 for more information.

The Zone Dialer Options location enables you to specify how a zone sends a report to a base station receiver. Refer to Section 14.3.8 Zone Dialer Options on page 59 for more information.

Zone Defaults

The default zone parameters for the ICP-CC404 Control Panel are listed in Table 43. You can program Zones 1 to 4 as any Zone Type, but you can only program Zones 5 to 8 as a 24-Hour Zone Type.

Table 43: Zone Programming Defaults

 

 

 

 

 

 

 

 

 

 

Zone

Default

 

Zone

Pulse

Pulse

Zone

Zone

Report

Dialer

Number

Type

Locations

Type

Count

Time

Options 1

Options 2

Code

Options

Zone 1

Delay 1

267 to 273

2

0

0

1

14

1

1

Zone 2

Handover

274 to 280

1

0

0

1

14

1

1

Zone 3

Handover

281 to 287

1

0

0

1

14

1

1

Zone 4

Instant

288 to 294

0

0

0

1

14

1

1

Zone 5

Fixed 24-hr burglary

295 to 301

12

0

0

1

12

1

1

Zone 6

Fixed 24-hr burglary

302 to 308

12

0

0

1

12

1

1

Zone 7

Fixed 24-hr fire

309 to 315

13

0

0

1

12

1

1

Zone 8

Fixed 24-hr tamper

316 to 322

9

0

0

1

12

1

1

14.3.1Zone Types

0 – Instant Zone

An Instant Zone (Contact ID Event Code 130) immediately sounds the sirens and operates the dialer when it is unsealed after the Exit Timer expires.

If an Instant Zone is not restored when the system is disarmed, a Zone Restore Report is automatically sent to the receiving party.

1 – Handover Zone

A Handover Zone (Contact ID Event Code 130) acts as an Instant Zone if it is activated by itself. If a Handover Zone is activated after a Delay Zone, the remaining Delay Time is handed over from the Delay Zone to the Handover Zone.

Handover can be sequential or non-sequential. The default settings is sequential handover. You can disable sequential handover by disabling Option 8 in Location 426 (refer to Section 18.3 System Options 3 on page 74).

If a Handover Zone is not restored when the system is disarmed, a Zone Restore Report is automatically sent to the receiving party.

2 – Delay-1 Zone

A Delay-1 Zone (Contact ID Event Code 130) has a delay time determined by the value in Locations 398 and 399 (refer to Section 17.2 Entry Timer 1 on

page 70). After Entry Time expires, the system activates an alarm.

If a Delay-1 Zone is not restored when the system is disarmed, a Zone Restore Report is sent to the receiving party.

3 – Delay-2 Zone

A Delay-2 Zone (Contact ID Event Code 130) has a delay time determined by the value in Locations 400 and 401 (refer to Section 17.3 Entry Timer 2 on

page 71). After Entry Time expires, the system activates an alarm.

If a Delay-2 Zone is not restored when the system is disarmed, a Zone Restore Report is sent to the receiving party.

4 – Reserved

5 – Reserved

6 – 24-Hour Medical Zone

A24-Hour Medical Zone (Contact ID Event Code

100) is always ready to activate the dialer, horn speaker, bell, and strobe, regardless of whether the system is armed or disarmed. A Medical Report is sent to the base station receiver. A 24-Hour Medical Zone does not send a Restore Report until the zone is restored.

7 – 24-Hour Panic Zone

A 24-Hour Panic Zone (Contact ID Event Code 120) is always ready to activate the dialer, horn speaker, bell, and strobe, regardless of whether the system is armed or disarmed. A Panic Report is sent to the base station receiver. A 24-Hour Panic Zone does not send a Restore Report until the zone is restored.

Bosch Security Systems, Inc. 12/08 F01U089401-02

55

Image 55
Contents ICP-CC404 Installation GuideCopyright Notice ICP-CC404 Installation Guide Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Quick Start FeaturesICP-CC404 Installation Guide 1.0 Introduction IntroductionZone Types Setting the Date and TimeZone Defaults ExampleProgramming with the Remote Codepad ICP-CC404 Installation Guide 2.0 ProgrammingCodepad Indicators ProgrammingProgramming Option Bits Installer’s Programming CommandsInstaller’s Programming Mode Commands Programming with the Programming KeyCommand 959 Test the Programming Key Command 958 Enable/Disable Zone Status ModeCommand 963 Copy the Programming Key to the Control Panel Command 960 Exit from the Installers Programming ModeCommand 965 Set Up Domestic Dialing Format Command 964 Erase the Programming KeyCommand 966 Enable or Disable Auto Step Mode Programming Command 965 DefaultsExample Auto Step Mode Enabled Example Auto Step Mode DisabledUsing this feature is not recommended Disable Factory DefaultsICP-CC404 Installation Guide 3.0 Codepad Indicators Codepad IndicatorsICP-CP508W Eight Zone LED Codepad ICP-CP508LW Eight Zone LCD Codepad Audible IndicatorsSystem Disarmed System Operations Disarming the System from Away ModeArming the System in Away Mode ICP-CC404 Installation Guide 4.0 System OperationsDisarming the System from Stay Mode Arming the System in Stay ModeEntry Guard Timer for Stay Mode Arming the System in Stay Mode Codepad Medical Alarm Codepad Duress AlarmCodepad Panic Alarm Codepad Fire AlarmLow Battery Fault Analysis ModeFault Descriptions Fault IndicatorsHorn Speaker Monitor Telephone Line FaultDate and Time Sensor WatchChanging or Deleting Remote Radio User Codes Remote Radio Transmitter OperationsIndications from Remote Radio Transmitter Operations Remote Radio User Code Priority LevelsArming in Stay Mode Codepad Indicators for Remote Radio User NumbersArming in Away Mode Disarming from Away ModePanic Alarm Disarming from Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations ICP-CC404 Installation Guide 6.0 System Functions Installer Code FunctionsSystem Functions Change Telco Arming or Disarming Sequence Codepad Indicators When Changing Phone NumbersChanging Domestic Phone Numbers Domestic Dialing DigitsSequence Codepad Indicators When ChangingTelco Arming or Disarming Dialing Digits Telco Arming or DisarmingSatellite Siren Service Mode Setting Stay Mode 2 ZonesMaster Code Functions Turning Telephone Monitor Mode On and OffTelephone Monitor Mode Indications Event Memory Recall ModeChanging and Deleting Remote Radio User Codes Remote Radio Numbers Displayed by the Codepad IndicatorsMaster Code Functions Changing and Deleting User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions Remote Arming by Telephone ICP-CC404 Installation Guide 7.0 Remote Arming by TelephoneICP-CC404 Installation Guide 8.0 Alarm Link Software Alarm Link SoftwareRemote Connect Domestic Dialing Function Alarm Link OptionsICP-CC404 Installation Guide 9.0 Domestic Dialing Domestic DialingSetting Up and Programming Domestic Reporting Contact ID Format ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsDialer Reporting Formats Transmission Formats+ 2 Express Reporting Format Point ID Codes10.1.3 4 + 2 Express Reporting Format Example Reporting in 4 + 2 Express FormatBasic Pager Reporting Format +2 Express Transmission Code DescriptionsZone Status Display Descriptions Basic Pager Display InformationSubscriber ID Number Zone StatusSystem Status ICP-CC404 Installation Guide 11.0 Dialer InformationDialer Information Primary Telephone Number for Receiver 1 and ReceiverSubscriber ID Number for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Transmission Format for Receiver 1 and ReceiverTelco Arming Sequence Dialing FormatTelco Disarming Sequence Answering Machine Bypass Telephone Line Fault OptionsCall Back Telephone Number Ring CountDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options User Codes Access CodeInstaller Code ICP-CC404 Installation Guide 13.0 Access CodeUser Code Priority EOL Resistor Value Day Alarm InformationICP-CC404 Installation Guide 14.0 Zone Information Zone InformationZone Reporting Information Zone ProgrammingZone Operating Information Zone OptionsZone Types Instant Zone Zone Programming DefaultsDelay-1 Zone Delay-2 Zone12 24-Hour Burglary Zone Keyswitch ZoneHour Holdup Zone Hour Tamper ZoneLatching Arm and Disarm in Away Mode Delay Alarm ReportingSilent Alarm Keyswitch Zone OptionsLatching Disarm from Stay Mode 1 or Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm and Disarm in Stay Mode Latching Arm in Stay ModeSwinger Shutdown Count for Dialer Swinger Shutdown Count for SirenZone Status Trouble Reports Zone Status Alarm Restore CodeSystem Reporting Information Zone Status Bypass ReportsCodepad Duress Report Zone Status Reporting OptionsOpen/Close Reports Open/Close Reporting OptionsSystem Status Low Battery Report System Status AUX Power Supply Fail ReportSystem Status AUX Power Supply Fail Restore Report System Status AC Fail Restore ReportTest Reporting Time System Status Low Battery Restore ReportSystem Status Access Denied System Status Reporting OptionsRedirecting Outputs to the Codepad Buzzer ICP-CC404 Installation Guide 16.0 Programmable OutputsProgrammable Outputs Test Reporting Dialer OptionsOutput Event Types Codepad Medical Alarm Day Alarm EnabledAUX Power Supply Fail Sensor Watch AlarmMimic System Fault Codepad Tamper Access DeniedAlarm When in Stay Mode Alarm When in Away ModeOutput Polarity Event Type Polarities Normally Open, One-Shot Low with ResetNormally Open, One-Shot Low with Alarm Normally Low, One-Shot Open with ResetSystem Event Timers Sensor Watch Time Entry Guard Timer for Stay ModeDelay Alarm Reporting Time Exit TimeKiss-Off Wait Time Auto Arming Pre-Alert TimerAuto Arming Time Auto Disarming TimeSystem Options System and Consumer OptionsArm/Disarm Tracking on Power Up Silent Access Denied Code RetriesSequential Handover Delay Panel Powers Up DisarmedConsumer Options Optional Equipment 19.10 TF008 Plug Pack TF008 19.9 PS101 Power Supply Module19.7 CP5 Eight Zone LCD Codepad CP508LW 19.8 CP105A Night Arm StationTerminal Descriptions Terminals and DescriptionsGlossary Of Terms This mode. Only the installer can program these zones Domestic alarm reportsThat an alarm was sent out Stay ModeICP-CC404 Wiring Diagram DiagramsICP-CC404 Component Overlay 4 not connected ICP-CC404 Installation Guide 21.0 Specifications SpecificationsWarranty Statement Advice to UsersProgramming Sheets ICP-CC404 Installation Guide 22.0 Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones Programming Sheets 22.0ICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets PRC Country CodesICP-CC404 Installation Guide Contents Index ICP-CC404 Installation Guide IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02