ICP-CC404 Installation Guide 14.0 Zone Information
The Zone Report Code determines whether the control panel sends Alarm Reports for the zone. Refer to Section 14.3.7 Zone Report Code on page 59 for more information.
The Zone Dialer Options location enables you to specify how a zone sends a report to a base station receiver. Refer to Section 14.3.8 Zone Dialer Options on page 59 for more information.
Zone Defaults
The default zone parameters for the
Table 43: Zone Programming Defaults
|
|
|
|
|
|
|
|
|
|
Zone | Default |
| Zone | Pulse | Pulse | Zone | Zone | Report | Dialer |
Number | Type | Locations | Type | Count | Time | Options 1 | Options 2 | Code | Options |
Zone 1 | Delay 1 | 267 to 273 | 2 | 0 | 0 | 1 | 14 | 1 | 1 |
Zone 2 | Handover | 274 to 280 | 1 | 0 | 0 | 1 | 14 | 1 | 1 |
Zone 3 | Handover | 281 to 287 | 1 | 0 | 0 | 1 | 14 | 1 | 1 |
Zone 4 | Instant | 288 to 294 | 0 | 0 | 0 | 1 | 14 | 1 | 1 |
Zone 5 | Fixed | 295 to 301 | 12 | 0 | 0 | 1 | 12 | 1 | 1 |
Zone 6 | Fixed | 302 to 308 | 12 | 0 | 0 | 1 | 12 | 1 | 1 |
Zone 7 | Fixed | 309 to 315 | 13 | 0 | 0 | 1 | 12 | 1 | 1 |
Zone 8 | Fixed | 316 to 322 | 9 | 0 | 0 | 1 | 12 | 1 | 1 |
14.3.1Zone Types
0 – Instant Zone
An Instant Zone (Contact ID Event Code 130) immediately sounds the sirens and operates the dialer when it is unsealed after the Exit Timer expires.
If an Instant Zone is not restored when the system is disarmed, a Zone Restore Report is automatically sent to the receiving party.
1 – Handover Zone
A Handover Zone (Contact ID Event Code 130) acts as an Instant Zone if it is activated by itself. If a Handover Zone is activated after a Delay Zone, the remaining Delay Time is handed over from the Delay Zone to the Handover Zone.
Handover can be sequential or
If a Handover Zone is not restored when the system is disarmed, a Zone Restore Report is automatically sent to the receiving party.
2 – Delay-1 Zone
A
page 70). After Entry Time expires, the system activates an alarm.
If a
3 – Delay-2 Zone
A
page 71). After Entry Time expires, the system activates an alarm.
If a
4 – Reserved
5 – Reserved
6 – 24-Hour Medical Zone
A
100) is always ready to activate the dialer, horn speaker, bell, and strobe, regardless of whether the system is armed or disarmed. A Medical Report is sent to the base station receiver. A
7 – 24-Hour Panic Zone
A