Bosch Appliances ICP-CC404 manual Glossary Of Terms

Page 79

ICP-CC404 Installation Guide 20.0 Terminals and Descriptions

20.2Glossary Of Terms

Table 65: Glossary

 

Term

Description

 

 

24-hour zone

A monitored input where tamper switches and emergency switches can be connected.

 

 

 

If one of these switches is violated at any time (whether the system is armed or

 

 

 

disarmed), an alarm is reported.

 

 

alarm condition

The status when an alarm system is armed and one of the detection devices is violated.

 

 

 

A 24-Hour zone (for example, a smoke detector) can activate when the system is

 

 

 

armed or disarmed.

 

 

answering machine

A condition that enables connection with the control panel for remote arming or remote

 

 

bypass

programming operations when there is an answering machine or facsimile machine on

 

 

 

the same telephone line.

 

 

Armed (System ON)

A status in which the system is ready to accept alarms.

 

 

automatic arming

Programming that allows the system to arm automatically at the same time each day in

 

 

 

AWAY Mode or STAY Mode 1.

 

 

automatic disarming

Programming that allows the system to disarm automatically at the same time each day

 

 

 

in AWAY Mode or STAY Mode 1.

 

 

AWAY or #

A codepad button used to execute any given command.

 

 

AWAY Mode

The mode used to arm your system when you leave your premises.

 

 

codepad

A device that allows you to perform all functions such as arming, disarming, and

 

 

 

programming of your alarm system.

 

 

day alarm

Programming that allows a combination of zones to be monitored while the system is

 

 

 

disarmed.

 

 

detector

A unit installed as a satellite component in a security system designed to detect an

 

 

 

intruder within a protected area. Some common forms of detection devices are passive

 

 

 

infrared, smoke, photo electric beams, reed switches, and vibration sensors.

 

 

dialer

An electronic device that uses tones or pulses to dial an electronic receiver such as a

 

 

 

monitoring station, mobile phone, or pocket pager. It uses the public switched

 

 

 

telephone network to send alarm or supervisory signals.

 

 

disarmed

A system status that does not accept alarms, except for 24-hour zones.

 

 

dual reporting

Reporting that allows your control panel to transmit alarm signals in two different

 

 

 

reporting formats (for example, the control panel can transmit to a monitoring station

 

 

 

and to a mobile phone, or to two different monitoring stations).

 

 

dynamic battery

A method used to monitor and test the condition of your backup battery.

 

 

testing

 

 

 

EDMSAT satellite

A self-contained siren unit complete with flashing blue strobe light and a backup

 

 

siren

battery that provides a higher level of security for an alarm system.

 

 

entry delay

A programmed delay of the system alarm responses that allows a person to enter a

 

 

 

building through the entry door to turn the system off.

 

 

entry warning

The beeping from a codepad during an entry delay as a reminder to disarm the system.

 

 

exit delay

A programmed delay of the system alarm responses that allows a person to leave a

 

 

 

building after turning the system on.

 

 

external equipment

Any device connected to a security system, such as a detector, codepad, or siren.

 

 

force arming

A method of overriding the safety feature that prevents arming with a faulted zone on a

 

 

 

control panel.

 

 

hand-over delay

If a system is armed and Zone 1 is violated, the entry delay starts timing. If Zone 2 is

 

 

 

violated, the entry delay time is handed over to the Zone 2 and so on, to Zones 3 and

 

 

 

4. This is known as sequential hand-over delay.

 

 

hand-held radio

A device used to arm and disarm a security system or to cause a panic alarm.

 

 

remote control

 

 

 

lockout dialer

A dialer that activates only once per zone per arming cycle.

 

 

lockout siren

A siren that activates only once per zone per arming cycle.

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. 12/08 F01U089401-02

79

Image 79
Contents ICP-CC404 Installation GuideCopyright Notice ICP-CC404 Installation Guide Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Quick Start FeaturesICP-CC404 Installation Guide 1.0 Introduction IntroductionZone Types Setting the Date and TimeZone Defaults ExampleProgramming with the Remote Codepad ICP-CC404 Installation Guide 2.0 ProgrammingCodepad Indicators ProgrammingProgramming Option Bits Installer’s Programming CommandsInstaller’s Programming Mode Commands Programming with the Programming KeyCommand 959 Test the Programming Key Command 958 Enable/Disable Zone Status ModeCommand 963 Copy the Programming Key to the Control Panel Command 960 Exit from the Installers Programming ModeCommand 965 Set Up Domestic Dialing Format Command 964 Erase the Programming KeyCommand 966 Enable or Disable Auto Step Mode Programming Command 965 DefaultsExample Auto Step Mode Enabled Example Auto Step Mode DisabledUsing this feature is not recommended Disable Factory DefaultsICP-CC404 Installation Guide 3.0 Codepad Indicators Codepad IndicatorsICP-CP508W Eight Zone LED Codepad ICP-CP508LW Eight Zone LCD Codepad Audible IndicatorsSystem Disarmed System Operations Disarming the System from Away ModeArming the System in Away Mode ICP-CC404 Installation Guide 4.0 System OperationsDisarming the System from Stay Mode Arming the System in Stay ModeEntry Guard Timer for Stay Mode Arming the System in Stay Mode Codepad Medical Alarm Codepad Duress AlarmCodepad Panic Alarm Codepad Fire AlarmLow Battery Fault Analysis ModeFault Descriptions Fault IndicatorsHorn Speaker Monitor Telephone Line FaultDate and Time Sensor WatchChanging or Deleting Remote Radio User Codes Remote Radio Transmitter OperationsIndications from Remote Radio Transmitter Operations Remote Radio User Code Priority LevelsArming in Stay Mode Codepad Indicators for Remote Radio User NumbersArming in Away Mode Disarming from Away ModePanic Alarm Disarming from Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations ICP-CC404 Installation Guide 6.0 System Functions Installer Code FunctionsSystem Functions Change Telco Arming or Disarming Sequence Codepad Indicators When Changing Phone NumbersChanging Domestic Phone Numbers Domestic Dialing DigitsSequence Codepad Indicators When ChangingTelco Arming or Disarming Dialing Digits Telco Arming or DisarmingSatellite Siren Service Mode Setting Stay Mode 2 ZonesMaster Code Functions Turning Telephone Monitor Mode On and OffTelephone Monitor Mode Indications Event Memory Recall ModeChanging and Deleting Remote Radio User Codes Remote Radio Numbers Displayed by the Codepad IndicatorsMaster Code Functions Changing and Deleting User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions Remote Arming by Telephone ICP-CC404 Installation Guide 7.0 Remote Arming by TelephoneICP-CC404 Installation Guide 8.0 Alarm Link Software Alarm Link SoftwareRemote Connect Domestic Dialing Function Alarm Link OptionsICP-CC404 Installation Guide 9.0 Domestic Dialing Domestic DialingSetting Up and Programming Domestic Reporting Contact ID Format ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsDialer Reporting Formats Transmission Formats+ 2 Express Reporting Format Point ID Codes10.1.3 4 + 2 Express Reporting Format Example Reporting in 4 + 2 Express FormatBasic Pager Reporting Format +2 Express Transmission Code DescriptionsZone Status Display Descriptions Basic Pager Display InformationSubscriber ID Number Zone StatusSystem Status ICP-CC404 Installation Guide 11.0 Dialer InformationDialer Information Primary Telephone Number for Receiver 1 and ReceiverSubscriber ID Number for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Transmission Format for Receiver 1 and ReceiverTelco Arming Sequence Dialing FormatTelco Disarming Sequence Answering Machine Bypass Telephone Line Fault OptionsCall Back Telephone Number Ring CountDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options User Codes Access CodeInstaller Code ICP-CC404 Installation Guide 13.0 Access CodeUser Code Priority EOL Resistor Value Day Alarm InformationICP-CC404 Installation Guide 14.0 Zone Information Zone InformationZone Reporting Information Zone ProgrammingZone Operating Information Zone OptionsZone Types Instant Zone Zone Programming DefaultsDelay-1 Zone Delay-2 Zone12 24-Hour Burglary Zone Keyswitch ZoneHour Holdup Zone Hour Tamper ZoneLatching Arm and Disarm in Away Mode Delay Alarm ReportingSilent Alarm Keyswitch Zone OptionsLatching Disarm from Stay Mode 1 or Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm and Disarm in Stay Mode Latching Arm in Stay ModeSwinger Shutdown Count for Dialer Swinger Shutdown Count for SirenZone Status Trouble Reports Zone Status Alarm Restore CodeSystem Reporting Information Zone Status Bypass ReportsCodepad Duress Report Zone Status Reporting OptionsOpen/Close Reports Open/Close Reporting OptionsSystem Status Low Battery Report System Status AUX Power Supply Fail ReportSystem Status AUX Power Supply Fail Restore Report System Status AC Fail Restore ReportTest Reporting Time System Status Low Battery Restore ReportSystem Status Access Denied System Status Reporting OptionsRedirecting Outputs to the Codepad Buzzer ICP-CC404 Installation Guide 16.0 Programmable OutputsProgrammable Outputs Test Reporting Dialer OptionsOutput Event Types Codepad Medical Alarm Day Alarm EnabledAUX Power Supply Fail Sensor Watch AlarmMimic System Fault Codepad Tamper Access DeniedAlarm When in Stay Mode Alarm When in Away ModeOutput Polarity Event Type Polarities Normally Open, One-Shot Low with ResetNormally Open, One-Shot Low with Alarm Normally Low, One-Shot Open with ResetSystem Event Timers Sensor Watch Time Entry Guard Timer for Stay ModeDelay Alarm Reporting Time Exit TimeKiss-Off Wait Time Auto Arming Pre-Alert TimerAuto Arming Time Auto Disarming TimeSystem Options System and Consumer OptionsArm/Disarm Tracking on Power Up Silent Access Denied Code RetriesSequential Handover Delay Panel Powers Up DisarmedConsumer Options Optional Equipment 19.10 TF008 Plug Pack TF008 19.9 PS101 Power Supply Module19.7 CP5 Eight Zone LCD Codepad CP508LW 19.8 CP105A Night Arm StationTerminal Descriptions Terminals and DescriptionsGlossary Of Terms This mode. Only the installer can program these zones Domestic alarm reportsThat an alarm was sent out Stay ModeICP-CC404 Wiring Diagram DiagramsICP-CC404 Component Overlay 4 not connected ICP-CC404 Installation Guide 21.0 Specifications SpecificationsWarranty Statement Advice to UsersProgramming Sheets ICP-CC404 Installation Guide 22.0 Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones Programming Sheets 22.0ICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets PRC Country CodesICP-CC404 Installation Guide Contents Index ICP-CC404 Installation Guide IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02