22.0

Programming Sheets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location

 

Options/Notes

 

 

 

 

Default/

 

 

 

Function

 

 

 

 

Programming Entry

 

 

 

 

 

 

 

 

 

 

425

1

Codepad panic to be silent

 

0

 

 

System Options 2

2

Codepad fire to be silent

 

 

 

 

 

 

Refer to page 73

4

Codepad medical to be silent

 

 

 

 

 

 

 

8

Access denied (code retries) to be silent

 

 

 

 

 

426

1

AC fail after 1 hr (disabled = after 2 min)

 

8

 

 

System Options 3

2

Ignore AC fail

 

 

 

 

 

 

Refer to page 74

4

Pulse count handover allowed

 

 

 

 

 

 

 

8

Handover delay to be sequential

 

 

 

 

 

427

1

Control panel to power up disarmed (if power reset)

 

0

 

 

System Options 4

2

Arm/disarm tracking on power up

 

 

 

 

 

 

Refer to page 74

4

Internal crystal to keep time

 

 

 

 

 

 

 

8

Night arm station, or RE005E installed

 

 

 

 

 

428

1

Test reports only when armed

 

0

 

 

Consumer Options 1

2

Test report after siren reset

 

 

 

 

 

 

Refer to page 75

4

Auto arm in STAY Mode 1

 

 

 

 

 

 

 

8

STAY indicator to display day alarm status

 

 

 

 

 

429

1

Codepad display extinguish after 60 sec

 

2

 

 

Consumer Options 2

2

Single button arming allowed (AWAY/STAY Modes 1 and 2)

 

 

 

 

 

Refer to page 75

4

Single button disarming allowed (STAY Modes 1 and 2)

 

 

 

 

 

 

 

8

Alarm memory reset on disarm

 

 

 

 

 

430

1

Codepad fault beeps allowed

 

5

 

 

Consumer Options 3

2

Use digit 3 for codepad duress alarm (instead of digit 9)

 

 

 

 

 

 

Refer to page 75

4

Alarms activate sirens and strobe outputs in STAY Modes 1 and 2

 

 

 

 

 

 

8

Reserved

 

 

 

 

 

431

1

Radio receiver (WE800E)

 

0

 

 

Radio Input Options

2

Latching keyswitch input

 

 

 

 

 

 

Refer to page 76

3

Momentary keyswitch input

 

 

 

 

 

 

 

4

Reserved

 

 

 

 

 

 

466 to 513

 

 

 

 

 

 

 

 

 

 

Domestic Telephone Numbers

Refer to page 41

748 to 749 Reserved

750 to 781 Country Codes Refer to page 93

Location 750: Country Code (tens digit)

0 2

Location 751: Country Code (units digit)

 

 

 

 

 

 

 

900

0

Defaulting system allowed

0

Default Options

15

Defaulting system disabled

 

 

 

 

 

Refer to page 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

901 to 904

 

Location 901: Hour of day (tens digit)

0 0 0 0

System Time

 

Location 902: Hour of day (units digit)

 

 

 

 

 

Refer to page 72

 

Location 903: Minute of day (tens digit)

 

 

 

 

 

 

 

Location 904: Minute of day (units digit)

 

 

 

 

 

905 to 910

Location 905: Day of the month (tens digit)

 

 

 

 

 

 

System Date

Location 906: Day of the month (units digit)

0 1 0 1 0 1

Refer to page 72

Location 907: Month of the year (tens digit)

 

 

 

 

 

 

 

Location 908: Month of the year (units digit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location 909: Current year (tens digit)

 

 

 

 

 

 

 

Location 910: Current year (units digit)

 

 

 

 

 

 

92

Bosch Security Systems, Inc. 12/08 F01U089401-02

Image 92
Contents Installation Guide ICP-CC404ICP-CC404 Installation Guide Copyright Notice Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Features ICP-CC404 Installation Guide 1.0 IntroductionIntroduction Quick StartSetting the Date and Time Zone DefaultsExample Zone TypesICP-CC404 Installation Guide 2.0 Programming Codepad IndicatorsProgramming Programming with the Remote CodepadInstaller’s Programming Commands Installer’s Programming Mode CommandsProgramming with the Programming Key Programming Option BitsCommand 958 Enable/Disable Zone Status Mode Command 959 Test the Programming KeyCommand 960 Exit from the Installers Programming Mode Command 963 Copy the Programming Key to the Control PanelCommand 966 Enable or Disable Auto Step Mode Command 964 Erase the Programming KeyCommand 965 Set Up Domestic Dialing Format Command 965 Defaults Example Auto Step Mode EnabledExample Auto Step Mode Disabled ProgrammingDisable Factory Defaults Using this feature is not recommendedICP-CP508W Eight Zone LED Codepad Codepad IndicatorsICP-CC404 Installation Guide 3.0 Codepad Indicators System Disarmed Audible IndicatorsICP-CP508LW Eight Zone LCD Codepad Disarming the System from Away Mode Arming the System in Away ModeICP-CC404 Installation Guide 4.0 System Operations System OperationsEntry Guard Timer for Stay Mode Arming the System in Stay ModeDisarming the System from Stay Mode Arming the System in Stay Mode Codepad Duress Alarm Codepad Panic AlarmCodepad Fire Alarm Codepad Medical AlarmFault Analysis Mode Fault DescriptionsFault Indicators Low BatteryTelephone Line Fault Date and TimeSensor Watch Horn Speaker MonitorRemote Radio Transmitter Operations Indications from Remote Radio Transmitter OperationsRemote Radio User Code Priority Levels Changing or Deleting Remote Radio User CodesCodepad Indicators for Remote Radio User Numbers Arming in Away ModeDisarming from Away Mode Arming in Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations Disarming from Stay ModePanic Alarm System Functions Installer Code FunctionsICP-CC404 Installation Guide 6.0 System Functions Codepad Indicators When Changing Phone Numbers Changing Domestic Phone NumbersDomestic Dialing Digits Change Telco Arming or Disarming SequenceCodepad Indicators When Changing Telco Arming or Disarming Dialing DigitsTelco Arming or Disarming SequenceSetting Stay Mode 2 Zones Satellite Siren Service ModeTurning Telephone Monitor Mode On and Off Telephone Monitor Mode IndicationsEvent Memory Recall Mode Master Code FunctionsRemote Radio Numbers Displayed by the Codepad Indicators Master Code FunctionsChanging and Deleting User Codes Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions ICP-CC404 Installation Guide 7.0 Remote Arming by Telephone Remote Arming by TelephoneRemote Connect Alarm Link SoftwareICP-CC404 Installation Guide 8.0 Alarm Link Software Alarm Link Options ICP-CC404 Installation Guide 9.0 Domestic DialingDomestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting ICP-CC404 Installation Guide 10.0 Dialer Reporting Formats Dialer Reporting FormatsTransmission Formats Contact ID FormatPoint ID Codes 10.1.3 4 + 2 Express Reporting FormatExample Reporting in 4 + 2 Express Format + 2 Express Reporting Format+2 Express Transmission Code Descriptions Basic Pager Reporting FormatBasic Pager Display Information Subscriber ID NumberZone Status Zone Status Display DescriptionsICP-CC404 Installation Guide 11.0 Dialer Information Dialer InformationPrimary Telephone Number for Receiver 1 and Receiver System StatusSecondary Telephone Number for Receiver 1 and Receiver Handshake Tone for Receiver 1 and ReceiverTransmission Format for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverTelco Disarming Sequence Dialing FormatTelco Arming Sequence Telephone Line Fault Options Call Back Telephone NumberRing Count Answering Machine BypassDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options Access Code Installer CodeICP-CC404 Installation Guide 13.0 Access Code User CodesUser Code Priority Day Alarm Information ICP-CC404 Installation Guide 14.0 Zone InformationZone Information EOL Resistor ValueZone Programming Zone Operating InformationZone Options Zone Reporting InformationZone Programming Defaults Delay-1 ZoneDelay-2 Zone Zone Types Instant ZoneKeyswitch Zone Hour Holdup ZoneHour Tamper Zone 12 24-Hour Burglary ZoneDelay Alarm Reporting Silent AlarmKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Disarm from Away Mode, Stay Mode 1, or Stay Mode Latching Arm and Disarm in Stay ModeLatching Arm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Siren Swinger Shutdown Count for DialerZone Status Alarm Restore Code System Reporting InformationZone Status Bypass Reports Zone Status Trouble ReportsZone Status Reporting Options Open/Close ReportsOpen/Close Reporting Options Codepad Duress ReportSystem Status AUX Power Supply Fail Report System Status AUX Power Supply Fail Restore ReportSystem Status AC Fail Restore Report System Status Low Battery ReportSystem Status Low Battery Restore Report System Status Access DeniedSystem Status Reporting Options Test Reporting TimeICP-CC404 Installation Guide 16.0 Programmable Outputs Programmable OutputsTest Reporting Dialer Options Redirecting Outputs to the Codepad BuzzerOutput Event Types Day Alarm Enabled AUX Power Supply FailSensor Watch Alarm Codepad Medical AlarmCodepad Tamper Access Denied Alarm When in Stay ModeAlarm When in Away Mode Mimic System FaultOutput Polarity Normally Open, One-Shot Low with Reset Normally Open, One-Shot Low with AlarmNormally Low, One-Shot Open with Reset Event Type PolaritiesSystem Event Timers Entry Guard Timer for Stay Mode Delay Alarm Reporting TimeExit Time Sensor Watch TimeAuto Arming Pre-Alert Timer Auto Arming TimeAuto Disarming Time Kiss-Off Wait TimeSystem and Consumer Options System OptionsSilent Access Denied Code Retries Sequential Handover DelayPanel Powers Up Disarmed Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.9 PS101 Power Supply Module 19.7 CP5 Eight Zone LCD Codepad CP508LW19.8 CP105A Night Arm Station 19.10 TF008 Plug Pack TF008Terminals and Descriptions Terminal DescriptionsGlossary Of Terms Domestic alarm reports That an alarm was sent outStay Mode This mode. Only the installer can program these zonesDiagrams ICP-CC404 Wiring DiagramICP-CC404 Component Overlay 4 not connected Specifications Warranty StatementAdvice to Users ICP-CC404 Installation Guide 21.0 SpecificationsICP-CC404 Installation Guide 22.0 Programming Sheets Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones 22.0 Programming SheetsICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets Country Codes PRCICP-CC404 Installation Guide Contents ICP-CC404 Installation Guide Index IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02