ICP-CC404 Installation Guide 6.0 System Functions

To enter Event Memory Recall Mode:

Enter your Master Code and press [8][AWAY]. Three beeps sound. The events are played back by the codepad indicators in reverse chronological order.

Example

If the events occurred in the following order:

1.System armed in AWAY Mode

2.Alarm in Zone 3

3.Alarm in Zone 4

4.System disarmed

The alarm memory plays back in this order:

1.All indicators off except MAINS (System disarmed)

2.Zone 4 and AWAY indicators light (Alarm in Zone 4)

3.Zone 3 and AWAY indicators light (Alarm in Zone 3)

4.AWAY indicator lights (System armed in AWAY Mode)

Each event is indicated by a beep and a lit indicator. Resetting a disarmed 24-Hour Alarm is indicated by a beep only.

After the last event, three beeps sound to indicate the end of playback. You can stop the replay at any time by pressing [AWAY].

If the system is armed in STAY Mode 1 or STAY Mode 2, the STAY indicator shows the event memory playback. There is no differentiation between STAY Mode 1 and STAY Mode 2.

If the control panel is powered down, the memory of all events is lost.

6.3Hold-Down Functions

Hold-down functions allow easy activation of specific operations. When you press and hold a button for

2 sec, two beeps sound and the corresponding function operates. The hold-down functions are listed below.

6.3.1Arming the System in AWAY Mode

Pressing and holding [#] until two beeps sound arms the system in AWAY Mode. This function operates only if you select Option 2 in Location 429 (refer to Section 18.6 Consumer Options 2 on page 75).

6.3.2Arming the System in STAY Mode 1

Pressing and holding [*] until two beeps sound arms the system in STAY Mode 1. This function operates only if you select Option 2 in Location 429 (refer to Section 18.6 Consumer Options 2 on page 75).

If there was no alarm during the armed cycle, pressing and holding [*] a second time disarms the system from STAY Mode 1. To enable single button disarming from STAY Mode 1 using this function, select Option 4 in Location 429.

If an alarm occurred or entry warning was activated, a valid User Code is required to disarm the system.

Refer to Section 14.3.6 Zone Options 2 on page 58 for information on programming each zone to automatically isolate in STAY Mode 1.

6.3.3Arming the System in STAY Mode 2

Pressing and holding [0] until two beeps sound arms the system in STAY Mode 2. This function operates only if you select Option 2 in Location 429 (refer to Section 18.6 Consumer Options 2 on page 75).

If there was no alarm during the armed cycle, pressing and holding [0] a second time disarms the system from STAY Mode 2. To enable single button disarming from STAY Mode 2 using this function, select Option 4 in Location 429.

If an alarm occurred or entry warning was activated, a valid User Code is required to disarm the system.

For more information, refer to Section 6.1.4 Setting STAY Mode 2 Zones on page 30 (using the Installer Code function) or Section 6.2.5 Setting STAY Mode 2 Zones on page 35 (using the Master Code function).

6.3.4Horn Speaker Test

Pressing and holding [1] until two beeps sound activates the horn speaker for a two-sec burst. No other sounding device operates during this mode.

6.3.5Bell Test

Pressing and holding [2] until two beeps sound activates the internal screamers for a two-sec burst. No other sounding device operates during this mode.

If the SS914 Satellite Siren (EDMSAT) is connected to the control panel, this function tests both the horn speaker and the strobe connected to the satellite siren for a 2-sec burst.

6.3.6Strobe Test

Pressing and holding [3] operates the strobe. No other device operates during this mode.

If the SS914 Satellite Siren (EDMSAT) is connected to the control panel, this function also tests the strobe on the satellite siren.

To turn the strobe test on:

Press and hold [3] until three beeps sound.

The strobe flashes.

To turn the strobe test off:

Press and hold [3] until two beeps sound.

The strobe stops flashing.

Bosch Security Systems, Inc. 12/08 F01U089401-02

37

Image 37
Contents ICP-CC404 Installation GuideCopyright Notice ICP-CC404 Installation Guide Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables ICP-CC404 Installation Guide 1.0 Introduction FeaturesIntroduction Quick StartZone Defaults Setting the Date and TimeExample Zone TypesCodepad Indicators ICP-CC404 Installation Guide 2.0 ProgrammingProgramming Programming with the Remote CodepadInstaller’s Programming Mode Commands Installer’s Programming CommandsProgramming with the Programming Key Programming Option BitsCommand 959 Test the Programming Key Command 958 Enable/Disable Zone Status ModeCommand 963 Copy the Programming Key to the Control Panel Command 960 Exit from the Installers Programming ModeCommand 965 Set Up Domestic Dialing Format Command 964 Erase the Programming KeyCommand 966 Enable or Disable Auto Step Mode Example Auto Step Mode Enabled Command 965 DefaultsExample Auto Step Mode Disabled ProgrammingUsing this feature is not recommended Disable Factory DefaultsICP-CC404 Installation Guide 3.0 Codepad Indicators Codepad IndicatorsICP-CP508W Eight Zone LED Codepad ICP-CP508LW Eight Zone LCD Codepad Audible IndicatorsSystem Disarmed Arming the System in Away Mode Disarming the System from Away ModeICP-CC404 Installation Guide 4.0 System Operations System OperationsDisarming the System from Stay Mode Arming the System in Stay ModeEntry Guard Timer for Stay Mode Arming the System in Stay Mode Codepad Panic Alarm Codepad Duress AlarmCodepad Fire Alarm Codepad Medical AlarmFault Descriptions Fault Analysis ModeFault Indicators Low BatteryDate and Time Telephone Line FaultSensor Watch Horn Speaker MonitorIndications from Remote Radio Transmitter Operations Remote Radio Transmitter OperationsRemote Radio User Code Priority Levels Changing or Deleting Remote Radio User CodesArming in Away Mode Codepad Indicators for Remote Radio User NumbersDisarming from Away Mode Arming in Stay ModePanic Alarm Disarming from Stay ModeFour-Channel Remote Radio Hand- Held Transmitter Operations ICP-CC404 Installation Guide 6.0 System Functions Installer Code FunctionsSystem Functions Changing Domestic Phone Numbers Codepad Indicators When Changing Phone NumbersDomestic Dialing Digits Change Telco Arming or Disarming SequenceTelco Arming or Disarming Dialing Digits Codepad Indicators When ChangingTelco Arming or Disarming SequenceSatellite Siren Service Mode Setting Stay Mode 2 ZonesTelephone Monitor Mode Indications Turning Telephone Monitor Mode On and OffEvent Memory Recall Mode Master Code FunctionsMaster Code Functions Remote Radio Numbers Displayed by the Codepad IndicatorsChanging and Deleting User Codes Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions Remote Arming by Telephone ICP-CC404 Installation Guide 7.0 Remote Arming by TelephoneICP-CC404 Installation Guide 8.0 Alarm Link Software Alarm Link SoftwareRemote Connect ICP-CC404 Installation Guide 9.0 Domestic Dialing Alarm Link OptionsDomestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting Dialer Reporting Formats ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsTransmission Formats Contact ID Format10.1.3 4 + 2 Express Reporting Format Point ID CodesExample Reporting in 4 + 2 Express Format + 2 Express Reporting FormatBasic Pager Reporting Format +2 Express Transmission Code DescriptionsSubscriber ID Number Basic Pager Display InformationZone Status Zone Status Display DescriptionsDialer Information ICP-CC404 Installation Guide 11.0 Dialer InformationPrimary Telephone Number for Receiver 1 and Receiver System StatusHandshake Tone for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverTransmission Format for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverTelco Arming Sequence Dialing FormatTelco Disarming Sequence Call Back Telephone Number Telephone Line Fault OptionsRing Count Answering Machine BypassDialer Options ICP-CC404 Installation Guide 12.0 Dialer OptionsDialer Options Installer Code Access CodeICP-CC404 Installation Guide 13.0 Access Code User CodesUser Code Priority ICP-CC404 Installation Guide 14.0 Zone Information Day Alarm InformationZone Information EOL Resistor ValueZone Operating Information Zone ProgrammingZone Options Zone Reporting InformationDelay-1 Zone Zone Programming DefaultsDelay-2 Zone Zone Types Instant ZoneHour Holdup Zone Keyswitch ZoneHour Tamper Zone 12 24-Hour Burglary ZoneSilent Alarm Delay Alarm ReportingKeyswitch Zone Options Latching Arm and Disarm in Away ModeLatching Arm and Disarm in Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Dialer Swinger Shutdown Count for SirenSystem Reporting Information Zone Status Alarm Restore CodeZone Status Bypass Reports Zone Status Trouble ReportsOpen/Close Reports Zone Status Reporting OptionsOpen/Close Reporting Options Codepad Duress ReportSystem Status AUX Power Supply Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AC Fail Restore Report System Status Low Battery ReportSystem Status Access Denied System Status Low Battery Restore ReportSystem Status Reporting Options Test Reporting TimeProgrammable Outputs ICP-CC404 Installation Guide 16.0 Programmable OutputsTest Reporting Dialer Options Redirecting Outputs to the Codepad BuzzerOutput Event Types AUX Power Supply Fail Day Alarm EnabledSensor Watch Alarm Codepad Medical AlarmAlarm When in Stay Mode Codepad Tamper Access DeniedAlarm When in Away Mode Mimic System FaultOutput Polarity Normally Open, One-Shot Low with Alarm Normally Open, One-Shot Low with ResetNormally Low, One-Shot Open with Reset Event Type PolaritiesSystem Event Timers Delay Alarm Reporting Time Entry Guard Timer for Stay ModeExit Time Sensor Watch TimeAuto Arming Time Auto Arming Pre-Alert TimerAuto Disarming Time Kiss-Off Wait TimeSystem Options System and Consumer OptionsSequential Handover Delay Silent Access Denied Code RetriesPanel Powers Up Disarmed Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.7 CP5 Eight Zone LCD Codepad CP508LW 19.9 PS101 Power Supply Module19.8 CP105A Night Arm Station 19.10 TF008 Plug Pack TF008Terminal Descriptions Terminals and DescriptionsGlossary Of Terms That an alarm was sent out Domestic alarm reportsStay Mode This mode. Only the installer can program these zonesICP-CC404 Wiring Diagram DiagramsICP-CC404 Component Overlay 4 not connected Warranty Statement SpecificationsAdvice to Users ICP-CC404 Installation Guide 21.0 SpecificationsProgramming Sheets ICP-CC404 Installation Guide 22.0 Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones Programming Sheets 22.0ICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets PRC Country CodesICP-CC404 Installation Guide Contents Index ICP-CC404 Installation Guide IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02