Bosch Appliances ICP-CC404 manual 374 to 392 to Strobe Output

Page 90

 

ICP-CC404 Installation Guide

22.0 Programming Sheets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location

 

Options/Notes

 

 

 

 

Default/

 

 

Function

 

 

Programming Entry

 

 

 

 

 

 

 

350 to 351

 

Location 350: tens digit

10

7

 

 

System Status – AC Fail Restore Report

 

Location 351: units digit

 

 

 

 

 

 

 

 

 

 

 

Refer to page 62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

352 to 353

 

Location 352: tens digit

10

1

 

 

System Status – Low Battery Report

 

Location 353: units digit

 

 

 

 

 

 

 

 

 

 

 

Refer to page 62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

354 to 355

 

Location 354: tens digit

10

6

 

 

System Status – Low Battery Restore Report

 

Location 355: units digit

 

 

 

 

 

 

 

 

 

 

 

Refer to page 63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

356 to 358

Location 356: Code retry limit (0 = unlimited)

6 7 12

 

 

System Status – Access Denied (Code Retry)

 

Location 357: tens digit

 

 

 

 

 

 

 

Refer to page 63

 

Location 358: units digit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

359

 

 

 

0

No System Status Reports allowed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

System Status Reporting Options

1

Report to Receiver 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 63

 

 

2

Report to Receiver 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Report to both Receiver 1 and Receiver 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Report to Receiver 2 only if Receiver 1 fails

 

 

 

 

 

 

 

 

 

 

360 to 366

 

 

 

 

 

Location 360: Hour of day (tens digit)

 

 

 

 

0 0 0 0 7 1 0

Test Report Time (Automatic)

 

 

 

Location 361: Hour of day (units digit)

 

 

 

 

 

 

 

 

 

 

Refer to page 63

 

 

 

 

 

Location 362: Minute of day (tens digit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location 363: Minute of day (units digit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location 364: Test Report (tens digit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location 365: Test Report (units digit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location 366: Repeat interval in days

 

 

 

 

 

 

 

 

 

 

367

 

 

 

0

No Test Reports allowed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Test Reporting Dialer Options

1

Report to Receiver 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to page 64

 

 

2

Report to Receiver 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Report to both Receiver 1 and Receiver 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Report to Receiver 2 only if Receiver 1 fails

 

 

 

 

 

 

 

 

 

 

368 to 397

 

Output 1

 

 

1 14 0 0 0 0

 

Relay Output

1 15 1 0 0 0

Outputs

 

 

 

 

 

 

 

(Horn speaker)

 

 

 

 

 

(Sirens running)

Refer to page 64

(368 to 373)

 

 

 

 

 

 

 

 

 

 

 

 

 

(386 to 391)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

7

10

2

1

3

 

 

 

 

 

 

 

0

13

2

1

0

1

 

 

 

Output 2

 

 

(Fire alarm with verification)

Codepad Buzzer

 

(Entry/exit plus day alarm)

 

 

(374 to 379)

 

 

 

 

 

 

 

 

 

 

 

 

 

(392 to 397)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

0

6

4

0

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Strobe Output

 

 

 

(Strobe – reset after 8 hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(380 to 385)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The first two locations (from the left) of the output definition provide the Event Code. For a complete list

 

 

of the Output Event Codes, refer to Section 16.2 Output Event Types on page 65.

 

 

 

 

 

 

 

The third location of the output definition is the output polarity. The options are:

 

 

 

 

 

 

 

 

 

 

 

 

0

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

8 Normally low, going open

 

 

 

 

 

 

1

Normally open, going low

 

 

 

 

 

9

Normally low, pulsing open

 

 

 

 

 

 

2

Normally open, pulsing low

 

 

 

 

 

10

Normally low, one shot open

 

 

 

 

 

 

3

Normally open, one shot low

 

 

 

 

 

11

Normally low, one shot open (can restart)

 

 

 

4

Normally open, one shot low (can restart)

12

Normally low, one shot open (can reset)

 

 

 

5

Normally open, one shot low (can reset)

13

Normally low, one shot open (alarm)

 

 

 

 

6

Normally open, one shot low (alarm)

 

 

 

14

Normally low, latching open

 

 

 

 

 

 

7

Normally open, latching low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The fourth location of the output definition is the time base. The options are:

 

 

 

 

 

 

 

 

 

 

 

 

1

200 ms

 

 

 

 

 

 

 

 

 

 

 

 

3

1 min

 

 

 

 

 

 

 

 

 

 

 

 

2

1 sec

 

 

 

 

 

 

 

 

 

 

 

 

4

1 hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

Bosch Security Systems, Inc. 12/08 F01U089401-02

Image 90
Contents Installation Guide ICP-CC404ICP-CC404 Installation Guide Copyright Notice Copyright NoticeContents ICP-CC404 Installation Guide Contents Figures Tables Introduction FeaturesICP-CC404 Installation Guide 1.0 Introduction Quick StartExample Setting the Date and TimeZone Defaults Zone TypesProgramming ICP-CC404 Installation Guide 2.0 ProgrammingCodepad Indicators Programming with the Remote CodepadProgramming with the Programming Key Installer’s Programming CommandsInstaller’s Programming Mode Commands Programming Option BitsCommand 958 Enable/Disable Zone Status Mode Command 959 Test the Programming KeyCommand 960 Exit from the Installers Programming Mode Command 963 Copy the Programming Key to the Control PanelCommand 964 Erase the Programming Key Command 965 Set Up Domestic Dialing FormatCommand 966 Enable or Disable Auto Step Mode Example Auto Step Mode Disabled Command 965 DefaultsExample Auto Step Mode Enabled ProgrammingDisable Factory Defaults Using this feature is not recommendedCodepad Indicators ICP-CC404 Installation Guide 3.0 Codepad IndicatorsICP-CP508W Eight Zone LED Codepad Audible Indicators ICP-CP508LW Eight Zone LCD CodepadSystem Disarmed ICP-CC404 Installation Guide 4.0 System Operations Disarming the System from Away ModeArming the System in Away Mode System OperationsArming the System in Stay Mode Disarming the System from Stay ModeEntry Guard Timer for Stay Mode Arming the System in Stay Mode Codepad Fire Alarm Codepad Duress AlarmCodepad Panic Alarm Codepad Medical AlarmFault Indicators Fault Analysis ModeFault Descriptions Low BatterySensor Watch Telephone Line FaultDate and Time Horn Speaker MonitorRemote Radio User Code Priority Levels Remote Radio Transmitter OperationsIndications from Remote Radio Transmitter Operations Changing or Deleting Remote Radio User CodesDisarming from Away Mode Codepad Indicators for Remote Radio User NumbersArming in Away Mode Arming in Stay ModeDisarming from Stay Mode Panic AlarmFour-Channel Remote Radio Hand- Held Transmitter Operations Installer Code Functions ICP-CC404 Installation Guide 6.0 System FunctionsSystem Functions Domestic Dialing Digits Codepad Indicators When Changing Phone NumbersChanging Domestic Phone Numbers Change Telco Arming or Disarming SequenceTelco Arming or Disarming Codepad Indicators When ChangingTelco Arming or Disarming Dialing Digits SequenceSetting Stay Mode 2 Zones Satellite Siren Service ModeEvent Memory Recall Mode Turning Telephone Monitor Mode On and OffTelephone Monitor Mode Indications Master Code FunctionsChanging and Deleting User Codes Remote Radio Numbers Displayed by the Codepad IndicatorsMaster Code Functions Changing and Deleting Remote Radio User CodesCodepad Indicators When Changing Domestic Telephone Numbers Change Telco Arming or Disarming Sequence Setting Stay Mode 2 Zones Turning Outputs On/Off Hold-Down Functions ICP-CC404 Installation Guide 7.0 Remote Arming by Telephone Remote Arming by TelephoneAlarm Link Software ICP-CC404 Installation Guide 8.0 Alarm Link SoftwareRemote Connect Domestic Dialing Alarm Link OptionsICP-CC404 Installation Guide 9.0 Domestic Dialing Domestic Dialing FunctionSetting Up and Programming Domestic Reporting Transmission Formats ICP-CC404 Installation Guide 10.0 Dialer Reporting FormatsDialer Reporting Formats Contact ID FormatExample Reporting in 4 + 2 Express Format Point ID Codes10.1.3 4 + 2 Express Reporting Format + 2 Express Reporting Format+2 Express Transmission Code Descriptions Basic Pager Reporting FormatZone Status Basic Pager Display InformationSubscriber ID Number Zone Status Display DescriptionsPrimary Telephone Number for Receiver 1 and Receiver ICP-CC404 Installation Guide 11.0 Dialer InformationDialer Information System StatusTransmission Format for Receiver 1 and Receiver Secondary Telephone Number for Receiver 1 and ReceiverHandshake Tone for Receiver 1 and Receiver Subscriber ID Number for Receiver 1 and ReceiverDialing Format Telco Arming SequenceTelco Disarming Sequence Ring Count Telephone Line Fault OptionsCall Back Telephone Number Answering Machine BypassICP-CC404 Installation Guide 12.0 Dialer Options Dialer OptionsDialer Options ICP-CC404 Installation Guide 13.0 Access Code Access CodeInstaller Code User CodesUser Code Priority Zone Information Day Alarm InformationICP-CC404 Installation Guide 14.0 Zone Information EOL Resistor ValueZone Options Zone ProgrammingZone Operating Information Zone Reporting InformationDelay-2 Zone Zone Programming DefaultsDelay-1 Zone Zone Types Instant ZoneHour Tamper Zone Keyswitch ZoneHour Holdup Zone 12 24-Hour Burglary ZoneKeyswitch Zone Options Delay Alarm ReportingSilent Alarm Latching Arm and Disarm in Away ModeLatching Arm in Stay Mode Latching Disarm from Away Mode, Stay Mode 1, or Stay ModeLatching Arm and Disarm in Stay Mode Latching Disarm from Stay Mode 1 or Stay ModeSwinger Shutdown Count for Siren Swinger Shutdown Count for DialerZone Status Bypass Reports Zone Status Alarm Restore CodeSystem Reporting Information Zone Status Trouble ReportsOpen/Close Reporting Options Zone Status Reporting OptionsOpen/Close Reports Codepad Duress ReportSystem Status AC Fail Restore Report System Status AUX Power Supply Fail ReportSystem Status AUX Power Supply Fail Restore Report System Status Low Battery ReportSystem Status Reporting Options System Status Low Battery Restore ReportSystem Status Access Denied Test Reporting TimeTest Reporting Dialer Options ICP-CC404 Installation Guide 16.0 Programmable OutputsProgrammable Outputs Redirecting Outputs to the Codepad BuzzerOutput Event Types Sensor Watch Alarm Day Alarm EnabledAUX Power Supply Fail Codepad Medical AlarmAlarm When in Away Mode Codepad Tamper Access DeniedAlarm When in Stay Mode Mimic System FaultOutput Polarity Normally Low, One-Shot Open with Reset Normally Open, One-Shot Low with ResetNormally Open, One-Shot Low with Alarm Event Type PolaritiesSystem Event Timers Exit Time Entry Guard Timer for Stay ModeDelay Alarm Reporting Time Sensor Watch TimeAuto Disarming Time Auto Arming Pre-Alert TimerAuto Arming Time Kiss-Off Wait TimeSystem and Consumer Options System OptionsPanel Powers Up Disarmed Silent Access Denied Code RetriesSequential Handover Delay Arm/Disarm Tracking on Power UpConsumer Options Optional Equipment 19.8 CP105A Night Arm Station 19.9 PS101 Power Supply Module19.7 CP5 Eight Zone LCD Codepad CP508LW 19.10 TF008 Plug Pack TF008Terminals and Descriptions Terminal DescriptionsGlossary Of Terms Stay Mode Domestic alarm reportsThat an alarm was sent out This mode. Only the installer can program these zonesDiagrams ICP-CC404 Wiring DiagramICP-CC404 Component Overlay 4 not connected Advice to Users SpecificationsWarranty Statement ICP-CC404 Installation Guide 21.0 SpecificationsICP-CC404 Installation Guide 22.0 Programming Sheets Programming Sheets22.0 Programming Sheets Burglary zones and four 24-hr zones 22.0 Programming SheetsICP-CC404 Installation Guide 22.0 Programming Sheets 374 to 392 to Strobe Output ICP-CC404 Installation Guide 22.0 Programming Sheets 22.0 Programming Sheets Country Codes PRCICP-CC404 Installation Guide Contents ICP-CC404 Installation Guide Index IndexHold Down Function Pulse Count Bosch Security Systems, Inc. F01U089401-02