Tools Needed:
Pliers
Attaching Disconnect Cables
NOTE: See idrive® main installation and owners manual for idrive® parts.
Attach the loose disconnect cable (located in opener hardware bag) to the opener with the “S” hook. Close both ends of the “S” hook with pliers, to lock assembly together.
Thread the disconnect cable (behind the counterbalance cable) through the hole in the right hand end bracket. Remove all slack between opener and right end bracket.
Disconnect
Cable
Hole in Right
End Bracket
Right Side of
End Bracket
Hole in | Close “S” Hook |
End Bracket
INSTALLATION
26 | Mounting Disconnect | |
Handle Bracket | ||
Tools Needed: | NOTE: See idrive® main installation and | |
Pencil | ||
owners manual for idrive® parts. | ||
Tape measure | Mark a location on the right jamb, 6 | |
1/8” Drill Bit | ||
feet above the floor to mount the | ||
7/16” Socket | disconnect handle bracket. | |
| ||
Driver | Drill 1/8” pilot holes for the lag screws. | |
Power Drill | ||
|
Align top of the bracket with the mark. Fasten bracket to the jamb with
(2) 1/4” x
6 ft.
(2) 1/4” x
Disconnect
Handle Bracket