Middleby Marshall PS360 Parts Manual and Service Manual Guide

Page 23

TERMINAL

BLOCK

RFI FILTER

Blue

Brown

SAFETY

SWITCH

CIRCUIT

BREAKERS

6A

TRANSFORMER 240-480V PRI.

FOR USE IN SPLIT BELT

CONVEYOR SPEED CONTROLLER

APPLICATIONS ONLY

PICKUP

120V SEC.

Black

Brown

Black

CIRCUIT

 

 

BREAKER

 

 

BLOCKS 20A

 

 

SOLID

 

 

STATE

 

 

RELAYS

 

 

Black

Brown

Black

CIRCUIT

Black

Brown

Black

CIRCUIT

 

 

 

 

 

 

 

 

 

BREAKERS

 

 

 

BREAKERS

 

 

 

6A

 

 

 

6A

#16 AWG

#16 AWG

#16 AWG

CONTACTOR

#16 AWG

#16 AWG

#16 AWG

CONTACTOR

 

 

 

 

 

 

CIRCUIT BREAKER 2A

Blue

CONVEYOR

DRIVE MOTOR Black

Red

CONVEYOR

 

DRIVE MOTOR

Black

 

Red

CONVEYOR SWITCH

Red

White

Black

CONVEYOR SPEED CONTROLLER PICKUP

 

 

Red

 

 

White

Pink

White

Black

 

BLOWER SWITCH

23

Black

Brown

Black

Black

Brown

Black

 

#12

#12

#12

#12 AWG

#12 AWG

#12 AWG

 

AWG

AWG

AWG

 

 

 

Black

Brown

#12 AWG

#12 AWG

Black #12 AWG

Black

Black

Black

Black

BLOWER

MOTOR

Brown

CENTRIFUGAL SWITCHES

Black

Black

BLOWER

MOTOR HEAT SWITCH

Brown

Brown

COOLING FAN

Brown

 

 

 

 

CIRCUIT

Brown

Brown

 

 

BREAKER

COOLING FAN

 

6A

 

 

 

 

 

 

 

Brown

COOLDOWN RELAY

 

COIL

 

 

 

 

 

Brown

 

 

COIL

 

PRESSURE SWITCH

HIGH LIMIT

 

 

RESET SWITCH

 

 

Brown

 

 

CONTROL MODULE

 

 

 

 

 

HIGH LIMIT CONTROL MODULE

 

 

 

 

Brown

Blue

 

 

 

 

 

 

 

TEMPERATURE

 

 

 

 

CONTROLLER

 

IMPORTANT An electrical wiring diagram for the oven is also located inside the machinery compartment.

TC

HEATING

ELEMENTSSOLID STATE

RELAYS

Wiring Diagram, PS360-U/-

SECTION 5 - ELECTRICAL WIRING

Fig. 5-1 L Electric Oven, 380-

DIAGRAMS

400V, 50 Hz, 1 Ph

 

ENGLISH

Image 23
Contents PS360WB PS360English For Your SafetyTable of Contents II. Oven Components see Figure III. Oven SpecificationsDescription English Oven UsesGas orifice and pressure specifications per oven cavity InstallationElectrical specifications per oven cavity 710 Installation KITInstallation kit components one kit required per cavity Additional installation kit components for gas ovensOther ventilation concerns II. Ventilation SystemRequirements RecommendationsIV. Thermocouple Installation III. AssemblyRemoving the Conveyor Drive Sprocket Conveyor Installation11 Conveyor and Master Link Orientation VI. Final AssemblyVIII. GAS Supply DURINGPRESSURETESTINGNOTEONEOFTHEFOLLOW- INGVII. Electrical Supply Gas Line Gas Utility Rough-In RecommendationsGas Meter Replacing the Gas Orifices if so required Preparation for Use with Various GasesOrifice Manifold Pressure Method Adjusting the Orifice Manifold Pressure and Heat InputVolumetric Method Checking the Gas Supply Inlet PressureLocation and Description of Controls Conveyor Switch Turns the conveyor drive motor on and offReset Switch Gas ovens only. Illuminates OperationII. Normal Operation STEP-BY-STEP DailystartupprocedureDailyshutdownprocedure III. Quick Reference Digital Temperature Controller Symptom IV. Quick Reference TroubleshootingMaintenance Daily MaintenanceRemoving the Conveyor II. Maintenance MonthlySplit Belt Disassembly and Cleaning III. Maintenance Every 3 MonthsDescription IV. Maintenance Every 6 MonthsKEY Spare Parts KIT Available sepa- rately. See Figure 400V, 50 Hz, 1 Ph DiagramsGas Oven An electrical wiring diagram for the oven isImportant also located inside CompartmentReguleret opvarmningszone Regulerede opvarmningszoner PS300 serien gas- og elektriske ovneMeddelelse DanskAFSNIT4-VEDLIGEHOLDELSE AFSNIT5-LEDNINGSDIAGRAMMERIndholdsfortegnelse Afsnit 3 BetjeningIII. Ovnspecifikationer Afsnit 1 Beskrivelse DanskOvnens Anvendelsesmuligheder II. Ovnkomponenter se FigurTabel 1-4 Specifikationer for gasåbning pr. ovnhulrum Afsnit 2 InstallationTabel 1-3 Generelle specifikationer pr. ovnhulrum Øversteovn InstallationssætYderligere komponenter til installationssæt til gasovne Enhed Beskrivelse DelnummerAndre ventilationsanliggender II. VentilationssystemKrav AnbefalingerIII. Montering IV. Installation AF TermoelementBemærk Installation AF TransportbåndDansk 11 Transportbånds- og samleledsretning VI. Endelig MonteringUnder Trykprøvning Skal ET AF Følgende Bemærkes VII. StrømforsyningVIII. Gasforsyning Forsigtig Gasudsivningstest, før ovnen betjenes Udførelse af disse procedurer, skal Der UdføresUdskiftning af gasåbninger hvis det kræves Forberedelse til brug med forskellige gastyperÅbningstrykmetoden manifold Volumetrisk metodeKontrol af gasforsyningstrykket indgang Justeringen af åbningens tryk manifold og varmetilførselHeat varme kontakt Tillader at brænder Afsnit 3 BetjeningPlacering OG Beskrivelse AF Betjeningsknapper II. Normal Betjening Trin for Trin DagligopstartprocedureDaglignedlukningsprocedure III. Hurtig Reference Digital Temperaturregulator IV. Hurtig Reference Fejlfinding Forsigtig Afsnit 4 VedligeholdelseBemærk Vedligeholdelse DagligtEksempler på markeringer II. Vedligeholdelse MånedligAfmontering og rengøring af dobbeltbånd III. Vedligeholdelse Hver 3. MånedEnhed Del nr Beskrivelse IV. Vedligeholdelse Hver 6. MånedNøgle Reservedelssæt fås separat. Se figur Afbrydere 380-400V, 50 Hz, 1 faseGasovn, 220-230V, 50Hz Der findes også et ledningsdiagramMaskinkassen PS360-U/-L eller