Henny Penny EEG-144, EEG-142, EEG-141, EEG-143 Selecting the Fryer Location Leveling the Fryer

Page 14

2-3. SELECTING THE FRYER LOCATION

2-4. LEVELING THE FRYER

The proper location of the fryer is very important for operation, speed, and convenience. The location of the open fryer should allow clearances for servicing and proper operation. Choose a location which will provide easy loading and unloading without interfering with the final assembly of food orders. Operators have found that frying from raw to finish, and holding the product in warmers provides fast continuous service. Keep in mind, the best efficiency will be obtained by a straight line operation, i.e. raw in one side and finished out the other side. Order assembly can be moved away with only a slight loss of efficiency.

To avoid fire, install the open fryer with minimum clearance from all combustible materials, 2 inches (5.08 cm) from the side and 4 inches (10.16 cm) from the back. Minimum clearance from all non-combustible materials, 0 inches

(0.00 cm) from the side and 0 inches (0.00 cm) from the back. If installed properly, the open fryer is designed for operation on non-combustible floors only

To prevent severe burns from splashing hot oil,

position and install fryer to prevent tipping or movement. Restraining ties may be used for stabilization.

For proper operation, the open fryer should be level from side-to-side and front to back. Using a level placed on the flat areas around the vat collar, on the middle well, and then adjust the casters until the unit is level.

2-2

609

Image 14
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Proper Care FeaturesIntroduction Safety AssistanceSafety Page Installation UnpackingSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Electrical Requirements Motor Bearings Lightingand Shutdown of the BurnersDimensions Page Operation Operating Components Refer to explanations on the next pagesFunction Operating ComponentsDescription Description Function JIB SET-UP Mode VAT Type Full or SplitFilling or Adding OIL Fill POT from BulkMorning START-UP Procedures Basic Operation Idle Mode OIL Guardian Auto Top-Off Selectinga Product Withadifferent Setpoint Replacing the JIBReservoir Removing/Cleaning ReservoirModel EEG-141 OIL Filling Oil ReservoirSmartfilter Express Filter Error Smartfilter ExpressDaily Filtering Check Filter Pan a new filter pad should be used onDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT Mode CLEAN-OUTCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Info Button Stats Actual Oil TemperatureRecovery Information for each Vat Filter Button StatsPreventive Maintenance Schedule ProcedureFrequencyClean Blower & Vents Page Information Mode Information Mode DetailsDetails Function Display EXTUE NEW OIL Reset usage data Assign Button Product Program Mode Modifying Product SettingsChange Product Names Alarms 1 Modifying Product SettingsTo Change Times and Temperatures Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Level 2 Programming Special Program Mode Filter ControlDegrees Fahrenheit or Celsius SP-1 Special Program ModeAudio Volume SP-4 Language SP-2Liquid or Solid Cooking Oil Used SP-6 Idle Mode Enabled SP-7Audio Tone SP-5 Filter Tracking Mode SP-8 MixedGlobal If Global is selected, press buttonCooking Indicator SP-15 Clean-Out Time SP-11Clean-Out Temperature SP-12 Polish Duration SP-92nd Language SP-16 2nd Volume SP-17Engery Save Mode SP-18 Fryer Type SP-19Bulk Oil Disposal SP-23 Autolift Enabled SP-21Bulk Oil Supply SP-22 Serial Number Log SP-24Longer Fill Time SP-28 Usage Code Change SP-26Dispose Requires Code ? SP-27 Let User Exit Fill SP-29Model EEG-141, 142, 143 Troubleshooting Trouble Shooting Guide Problem Cause CorrectionRemove the right side panel Error Codes Display Cause CorrectionError Codes Display Cause Correction ClosedPage Henny Penny Corporation Box Eaton,OH Toll free in USA