6-1. SPECIAL PROGRAM MODE (Continued)

Model EEG-141, 142, 143, 144

Polish Duration (SP-9)

Press button and “SP-9 POLISH TIME” flashes in the left display. Press the or , or use product buttons, to change the polish time, from 0 to 10 minutes.

Change Filter Pad Reminder Time (SP-10)

Press button and “SP-10 CHANGE PAD’ REMINDER” flashes in the left display. Press the or , or use product buttons, to change the time from 0 to 100 hours.

Clean-Out Time (SP-11)

Press button and “SP-11 CLEAN-OUT TIME” flashes in the left display. Press the or , or use product buttons, to change the time from 0 to 99 minutes.

Clean-Out Temperature (SP-12)

Press button and “SP-12 CLEAN-OUT TEMP” flashes in the left display. Press the or , or use product buttons, to change the temperature from 0 to 195o F (90o C).

Cooking User IO (SP-13)

Press button and “SP-13 COOKING USER IO”

flashes in the display. Press the

or buttons to choose

“SHOWPREV” or “SHOW----”.

 

Setting SP-13 to SHOWPREV means after a cook cycle the display shows the last menu item cooked. SHOW---- means

after a cook cycle “----” shows in the display and a menu item

needs selected before starting the next cook cycle.

Number of Baskets (SP-14)

Press button and “SP-14 NUMBER OF BASKETS” flashes in the left display. Press the or buttons to choose 2 or 4 baskets per well.

Cooking Indicator (SP-15)

Press button and “SP-15 SHOW COOKING INDICATOR” flashes in the left display. Press the or buttons to choose YES, and during a cook cycle, “*” shows which timer is counting-down. Choose NO and “*” will not show during a cook cycle.

6-6

909

Image 62
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Proper Care FeaturesIntroduction Safety AssistanceSafety Page Installation UnpackingSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Electrical Requirements Motor Bearings Lightingand Shutdown of the BurnersDimensions Page Operation Operating Components Refer to explanations on the next pagesFunction Operating ComponentsDescription Description Function JIB SET-UP Mode VAT Type Full or SplitFilling or Adding OIL Fill POT from BulkMorning START-UP Procedures Basic Operation Idle Mode OIL Guardian Auto Top-Off Selectinga Product Withadifferent Setpoint Replacing the JIBReservoir Removing/Cleaning ReservoirModel EEG-141 OIL Filling Oil ReservoirSmartfilter Express Filter Error Smartfilter ExpressDaily Filtering Check Filter Pan a new filter pad should be used onDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT Mode CLEAN-OUTCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Info Button Stats Actual Oil TemperatureRecovery Information for each Vat Filter Button StatsPreventive Maintenance Schedule ProcedureFrequencyClean Blower & Vents Page Information Mode Information Mode DetailsDetails Function Display EXTUE NEW OIL Reset usage data Assign Button Product Program Mode Modifying Product SettingsChange Product Names Alarms 1 Modifying Product SettingsTo Change Times and Temperatures Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Level 2 Programming Special Program Mode Filter ControlDegrees Fahrenheit or Celsius SP-1 Special Program ModeAudio Volume SP-4 Language SP-2Liquid or Solid Cooking Oil Used SP-6 Idle Mode Enabled SP-7Audio Tone SP-5 Filter Tracking Mode SP-8 MixedGlobal If Global is selected, press buttonCooking Indicator SP-15 Clean-Out Time SP-11Clean-Out Temperature SP-12 Polish Duration SP-92nd Language SP-16 2nd Volume SP-17Engery Save Mode SP-18 Fryer Type SP-19Bulk Oil Disposal SP-23 Autolift Enabled SP-21Bulk Oil Supply SP-22 Serial Number Log SP-24Longer Fill Time SP-28 Usage Code Change SP-26Dispose Requires Code ? SP-27 Let User Exit Fill SP-29Model EEG-141, 142, 143 Troubleshooting Trouble Shooting Guide Problem Cause CorrectionRemove the right side panel Error Codes Display Cause CorrectionError Codes Display Cause Correction ClosedPage Henny Penny Corporation Box Eaton,OH Toll free in USA