Henny Penny EEG-144, EEG-142, EEG-141, EEG-143 warranty Error Codes Display Cause Correction, Closed

Page 70

Model EEG-141, 142, 143, 144

7-2. ERROR CODES

 

 

 

DISPLAY

CAUSE

CORRECTION

 

 

 

“E-20-A”

• Pressure Switch

• If fan is not running, have pressure switch checked; should be

“FAN SENSOR

failure

open circuit if no air pressure

STUCK

• wiring problem

• If fan is running, wiring error, or relay on I/O board closed

CLOSED”

• I/O board failure

 

 

 

 

“E-20-B”

• Pressure Switch

• Press power button to vat off and back on again, if E-20-B

“NO DRAFT”

failure/hose loose

persists, have pressure switch checked; should be open circuit

“CHECK

• Draft Fan failure/

if no air pressure; make sure hose is connected to fan and

FAN”

low voltage

pressure switch

 

• Flue or hood

• Have draft fan checked; low voltage going to fan

 

obstructions

• check the fryer flue and hood system for obstructions

 

 

 

“E-20-D”

• Failure to ignite/

• Press power button to vat off and back on again, if E-20-D

“IGNITION”

no flame sense

persists, check gas line connections; check gas shut-off valve;

“FAILURE”

 

have ignition module checked; gas valve checked; flame sensor

 

 

gap checked; gas valve and ignition module wiring checked

 

 

 

“E-21”

• Slow heat recovery

• Have a certified service technician check the fryer for correct

 

 

voltage to the unit; have heat circuit checked; have unit

 

 

checked for loose or burnt wire

 

 

 

“E-22”‘NO

• Burner not igniting

• Have gas valve and heat circuit checked

HEAT” “CHECK

 

 

GAS VALVE”

 

 

 

 

 

“E-41”, “E-46”

• Programming

• Press power button to vat off and back on again, if any

 

failure

of the error codes, have the controls re-initialized; if error code

 

 

persists, have the control board replaced

 

 

 

“E-47”

•Analog converter

• Press power button to vat off and back on again, if “E-47”

 

chip or 12 volt

persists, have the I/O board, or the PC board replaced; if

 

supply failure

speaker tones are quiet, probably I/O board failure; have the

 

 

I/O boardreplaced

 

 

 

“E-48”

• Input system error

• Have PC board replaced

 

 

 

“E-54C”

• Temperature input

• Turn switch to OFF, then back to ON; have control PC board

 

error

replaced if “E-54C” persists

 

 

 

“E-60”

• AIF PC board not

• Press power button to vat off and back on again if “E-60”

 

communicating with

persists, have the connector between the PC boards checked;

 

control PC board

replace AIF PC board or control PC board if necessary

7-4

 

809

Image 70
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Introduction FeaturesProper Care Safety AssistanceSafety Page Installation UnpackingSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Electrical Requirements Motor Bearings Lightingand Shutdown of the BurnersDimensions Page Operation Operating Components Refer to explanations on the next pagesDescription Operating ComponentsFunction Description Function JIB SET-UP Mode VAT Type Full or SplitFilling or Adding OIL Fill POT from BulkMorning START-UP Procedures Basic Operation Idle Mode OIL Guardian Auto Top-Off Selectinga Product Withadifferent Setpoint Replacing the JIBReservoir Removing/Cleaning ReservoirModel EEG-141 OIL Filling Oil ReservoirSmartfilter Express Filter Error Smartfilter ExpressDaily Filtering Check Filter Pan a new filter pad should be used onDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT Mode CLEAN-OUTCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Info Button Stats Actual Oil TemperatureRecovery Information for each Vat Filter Button StatsPreventive Maintenance Schedule ProcedureFrequencyClean Blower & Vents Page Information Mode Information Mode DetailsDetails Function Display EXTUE NEW OIL Reset usage data Change Product Names Product Program Mode Modifying Product SettingsAssign Button Alarms 1 Modifying Product SettingsTo Change Times and Temperatures Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Level 2 Programming Special Program Mode Filter ControlDegrees Fahrenheit or Celsius SP-1 Special Program ModeAudio Volume SP-4 Language SP-2Audio Tone SP-5 Idle Mode Enabled SP-7Liquid or Solid Cooking Oil Used SP-6 Filter Tracking Mode SP-8 MixedGlobal If Global is selected, press buttonCooking Indicator SP-15 Clean-Out Time SP-11Clean-Out Temperature SP-12 Polish Duration SP-92nd Language SP-16 2nd Volume SP-17Engery Save Mode SP-18 Fryer Type SP-19Bulk Oil Disposal SP-23 Autolift Enabled SP-21Bulk Oil Supply SP-22 Serial Number Log SP-24Longer Fill Time SP-28 Usage Code Change SP-26Dispose Requires Code ? SP-27 Let User Exit Fill SP-29Model EEG-141, 142, 143 Troubleshooting Trouble Shooting Guide Problem Cause CorrectionRemove the right side panel Error Codes Display Cause CorrectionError Codes Display Cause Correction ClosedPage Henny Penny Corporation Box Eaton,OH Toll free in USA