Henny Penny EEG-143, EEG-142, EEG-141, EEG-144 warranty Rinse Complete YES no

Page 43

3-17. CLEAN-OUT MODE (Continued)

609

Model EEG-141, 142, 143, 144

11.Return empty filter drain pan to fryer and press √ button. Display then shows “VAT EMTY” “YES NO”.

12.Once vat is empty, press √ button and display shows “SCRUB VAT COMPLETE” “YES NO”. Use brush and scour pad to clean vat, if needed.

Do not use steel wool, other abrasive cleaners, or cleaners/ sanitizers containing chlorine, bromine, iodine, or ammonia chemicals as these will deteriorate the stainless steel material and shorten the life of the unit.

use a water jet (pressure sprayer) to clean unit or Docomponent damage could result.

13.Once vat is clean, press the √ button and display shows “RINSE VAT”. (If drain is not open, display shows “OPEN DRAIN” Open the drain.)

14.Pour clean water and approximately 8 ozs. (0.24 liters) of distilled vinegar solution into vat to rinse vat and allow rinse water to drain into drain pan. Rinse at least 3 times, but be careful not tooverfill the drain pan. Display now shows

“RINSE COMPLETE” “YES NO”

15.Once vat is completely rinsed, press the √ button and display

shows “CLEARX SOLUTION FROM OIL LINES” “√ =PUMP” “ =DONE”

To make sure no cleaning solution remains in the oil lines, press

Xand hold √ button for a few seconds. Once lines are clear, press button and display shows VAT DRY?” “YES NO”. Push

drain knob and close drain.

16.Pull drain pan from under fryer and dispose of rinse water.

17.Thoroughly dry the vat with a towel, and then press the √ button. Controls return to normal operations.

Make sure the inside of the vat, the drain valve opening, and all the parts that come in contact with the new oil are as dry as possible.

18.Make sure the drain is closed and return the filter pan assembly,

withFillingneworfilterAddingpad,Oilto the fryer. Fill vat with oil following the instructions from Section 3-3.

3-22

Image 43
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Introduction FeaturesProper Care Assistance SafetySafety Page Unpacking InstallationSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Motor Bearings Lightingand Shutdown of the Burners Electrical RequirementsDimensions Page Refer to explanations on the next pages Operation Operating ComponentsDescription Operating ComponentsFunction Description Function JIB VAT Type Full or Split SET-UP ModeFill POT from Bulk Filling or Adding OILMorning START-UP Procedures Basic Operation Idle Mode Selectinga Product Withadifferent Setpoint Replacing the JIB OIL Guardian Auto Top-OffFilling Oil Reservoir Removing/Cleaning ReservoirModel EEG-141 OIL ReservoirSmartfilter Express Smartfilter Express Filter ErrorCheck Filter Pan a new filter pad should be used on Daily FilteringDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT CLEAN-OUT ModeCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Filter Button Stats Actual Oil TemperatureRecovery Information for each Vat Info Button StatsProcedureFrequency Preventive Maintenance ScheduleClean Blower & Vents Page Information Mode Details Information ModeFunction Display EX DetailsTUE NEW OIL Reset usage data Change Product Names Product Program Mode Modifying Product SettingsAssign Button Quality Timer hold time Modifying Product SettingsTo Change Times and Temperatures Alarms 1MixFilterdAfterFil TrackingX Number of Loads Filter Control Level 2 Programming Special Program ModeLanguage SP-2 Special Program ModeAudio Volume SP-4 Degrees Fahrenheit or Celsius SP-1Audio Tone SP-5 Idle Mode Enabled SP-7Liquid or Solid Cooking Oil Used SP-6 Mixed Filter Tracking Mode SP-8If Global is selected, press button GlobalPolish Duration SP-9 Clean-Out Time SP-11Clean-Out Temperature SP-12 Cooking Indicator SP-15Fryer Type SP-19 2nd Volume SP-17Engery Save Mode SP-18 2nd Language SP-16Serial Number Log SP-24 Autolift Enabled SP-21Bulk Oil Supply SP-22 Bulk Oil Disposal SP-23Let User Exit Fill SP-29 Usage Code Change SP-26Dispose Requires Code ? SP-27 Longer Fill Time SP-28Model EEG-141, 142, 143 Problem Cause Correction Troubleshooting Trouble Shooting GuideRemove the right side panel Display Cause Correction Error CodesClosed Error Codes Display Cause CorrectionPage Henny Penny Corporation Box Eaton,OH Toll free in USA